Abstract Weak measurement (WM) based on post-selection is a useful tool for precision metrology due to the ability of amplifying weak physical effects. In this paper, we reveal the underlying mechanism of the amplification in the post-selected WM based on the weak-value amplification (WVA) and the almost balanced weak-values amplification (ABWVA) strategies. We find that the amplification stems from the interference between the local oscillator and signal components which are respectively associated with the initial system state and the state disturbance induced by the weak coupling. The magnitude of the amplification is proportional to the interference strength which is dominated by the post-selection and the coupling strength. Furthermore, our theory can perfectly explain the amplification limit in the WVA strategy and the anomalous amplification in the ABWVA strategy.
Abstract Weak measurement (WM) based on post-selection is a useful tool for precision metrology due to the ability of amplifying weak physical effects. In this paper, we reveal the underlying mechanism of the amplification in the post-selected WM based on the weak-value amplification (WVA) and the almost balanced weak-values amplification (ABWVA) strategies. We find that the amplification stems from the interference between the local oscillator and signal components which are respectively associated with the initial system state and the state disturbance induced by the weak coupling. The magnitude of the amplification is proportional to the interference strength which is dominated by the post-selection and the coupling strength. Furthermore, our theory can perfectly explain the amplification limit in the WVA strategy and the anomalous amplification in the ABWVA strategy.
We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.
Abstract We present a theoretical investigation of weak-value amplification (WVA) under decoherence, quantifying its metrological capabilities through the quantum Fisher information (QFI). By modeling decoherence via Kraus operators acting before and after the weak measurement interaction, we derive exact expressions for the QFI governing parameter estimation of a weak coupling strength. These analytical results reveal the fundamental limitation imposed by decoherence on the QFI achievable via WVA. From these results, the optimal post-selection state that maximizes the QFI can be derived for different noise environments. Through paradigmatic examples, including amplitude damping and depolarizing channels, we demonstrate a key distinction: the optimal post-selection evolves with the noise strength in the amplitude damping channel, but is fixed in the depolarizing channel. This work provides both theoretical insights and practical guidance for optimizing metrological schemes based on WVA in realistic decoherent environments.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.
Weak amplification is a signal enhancement technique which is used to measure tiny changes that otherwise cannot be determined because of technical limitations. It is based on: a) the existence of a weak interaction which couples a property of a system (the system) with a separate degree of freedom (the pointer), and b) the measurement of an anomalously large mean value of the pointer state (weak mean value), after appropriate pre-and post-selection of the state of the system. Unfortunately, the weak amplification process is generally accompanied by severe losses of the detected signal, which limits its applicability. However, we will show here that since weak amplification is essentially the result of an interference phenomena, it should be possible to use the degree of interference (weak interference) to get relevant information about the physical system under study in a more general scenario, where the signal is not severely depleted (high-signal regime).