Abstract We present a theoretical investigation of weak-value amplification (WVA) under decoherence, quantifying its metrological capabilities through the quantum Fisher information (QFI). By modeling decoherence via Kraus operators acting before and after the weak measurement interaction, we derive exact expressions for the QFI governing parameter estimation of a weak coupling strength. These analytical results reveal the fundamental limitation imposed by decoherence on the QFI achievable via WVA. From these results, the optimal post-selection state that maximizes the QFI can be derived for different noise environments. Through paradigmatic examples, including amplitude damping and depolarizing channels, we demonstrate a key distinction: the optimal post-selection evolves with the noise strength in the amplitude damping channel, but is fixed in the depolarizing channel. This work provides both theoretical insights and practical guidance for optimizing metrological schemes based on WVA in realistic decoherent environments.
Abstract We present a theoretical investigation of weak-value amplification (WVA) under decoherence, quantifying its metrological capabilities through the quantum Fisher information (QFI). By modeling decoherence via Kraus operators acting before and after the weak measurement interaction, we derive exact expressions for the QFI governing parameter estimation of a weak coupling strength. These analytical results reveal the fundamental limitation imposed by decoherence on the QFI achievable via WVA. From these results, the optimal post-selection state that maximizes the QFI can be derived for different noise environments. Through paradigmatic examples, including amplitude damping and depolarizing channels, we demonstrate a key distinction: the optimal post-selection evolves with the noise strength in the amplitude damping channel, but is fixed in the depolarizing channel. This work provides both theoretical insights and practical guidance for optimizing metrological schemes based on WVA in realistic decoherent environments.
In conventional measurement, to reach the greatest accuracy of parameter estimation, all samples must be measured since each independent sample contains the same quantum Fisher information. In postselected metrology, postselection can concentrate the quantum Fisher information of the initial samples into a tiny post-selected sub-ensemble. It has been proven that this quantum advantage can not be realized in any classically commuting theory. In this work, we present that the advantage of postselection in weak value amplification (WVA) can not be achieved without quantum coherence. The quantum coherence of the initial system is closely related to the preparation costs and measurement costs in parameter estimation. With the increase of initial quantum coherence, the joint values of preparation costs and measurement costs can be optimized to smaller. Moreover, we derive an analytical tradeoff relation between the preparation, measurement and the quantum coherence. We further experimentally test the tradeoff relation in a linear optical setup. The experimental and theoretical results are in good agreement and show that the quantum coherence plays a key role in bounding the resource costs in the postselected metrology process.
Abstract Weak measurement (WM) based on post-selection is a useful tool for precision metrology due to the ability of amplifying weak physical effects. In this paper, we reveal the underlying mechanism of the amplification in the post-selected WM based on the weak-value amplification (WVA) and the almost balanced weak-values amplification (ABWVA) strategies. We find that the amplification stems from the interference between the local oscillator and signal components which are respectively associated with the initial system state and the state disturbance induced by the weak coupling. The magnitude of the amplification is proportional to the interference strength which is dominated by the post-selection and the coupling strength. Furthermore, our theory can perfectly explain the amplification limit in the WVA strategy and the anomalous amplification in the ABWVA strategy.
The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.
Weak value amplification (WVA) is a technique by which one can magnify the apparent strength of a measurement signal. Some have claimed that WVA can outperform more conventional measurement schemes in parameter estimation. Nonetheless, a significant body of theoretical work has challenged this perspective, suggesting WVA to be fundamentally suboptimal. Optimal measurements may not be practical, however. Two practical considerations that have been conjectured to afford a benefit to WVA over conventional measurement are certain types of noise and detector saturation. Here, we report a theoretical study of the role of saturation and pixel noise in WVA-based measurement, in which we carry out a Bayesian analysis of the Fisher information available using a saturable, pixelated, digitized, and/or noisy detector. We draw two conclusions: first, that saturation alone does not confer an advantage to the WVA approach over conventional measurement, and second, that WVA can outperform conventional measurement when saturation is combined with intrinsic pixel noise and/or digitization.
Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.
Quantum metrology is a subject of studying quantum measurement and quantum statistical deduction, and the precision of parameter estimation can be enhanced by quantum properties. In general, the process of parameter estimation includes four steps:preparation of probe state, parameterization process, measurement, and data processing. Of these four steps, the preparation of probe state is the most crucial. However, in practical applications, in the process of preparing quantum probe state, the probe system will couple to its environment, which will inevitably cause the quantum properties of the probe system to deteriorate, and thus reducing the precision of quantum parameter estimation. The dynamics of quantum Fisher information (QFI) for W state and Greenberger-Horne-Zeilinger (GHZ) state have been studied in decoherence channels. Because W state and GHZ state have different entanglement properties, the studies of the dynamics of QFI for the superposition of W state and GHZ state are of practical significance in quantum metrology field. In this paper, the dynamics of QFIs for the superposition of W state and GHZ state in three typical decoherence channels (depolarization channel, amplitude damping channel and phase damping channel) are studied. In the four steps of quantum parameter estimation, our major attention is paid to the first step (i.e., the preparation of probe state). For comparison, the QFIs of different probe states are studied, with the other three steps fixed, i.e., all the probe states will undergo the same parameterization, measurement and estimation process. The parameterization process involved here is a quantum spin operation (specified by the spin rotation direction), which is chosen to maximize the QFI of the probe state. The initial probe states under consideration are the superpositions of W state and GHZ state of three-particle and five-particle systems, and the QFI dynamics of those probe states are studied in the three different typical decoherence channels. By using the operator-sum (Kraus) representation of those three typical decoherence channels, the QFI dynamics of the probe state can be analytically derived in three different decoherence channels. The results show that in the depolarization channel, the maximum QFI of the probe state decreases with the decoherence evolving to zero in the end; in the amplitude damping channel, the QFI of the probe state decreases to the minimum with the decoherence evolution and then increases to the shot noise limit; in the phase damping channel, the QFI of the probe state decreases with the evolution of decoherence, but the final stable value is not zero. Further analyses show that W state component of the superposition plays a role in resisting phase damping and the GHZ state component plays a role in resisting amplitude damping. These results can help us to choose the optimal probe state for maximizing the estimation precision in practice.