AMMONIA BEAM MASER

Murray, Iii Sargent

Published Mar 5, 2018• 0 citations
Publisher

Abstract

To treat the laser in a realistic way, we need the density matrix concepts and formalism given in Chap. 7. This material makes it possible to incorporate dipole phase decays due, for example, to collisions and to treat multimode electric fields in a straightforward way. Nevertheless, it is gratifying to find that we can already determine the field intensity for a simplified model of the ammonia beam maser, the first device of the maser-laser genre. The maser was originally conceived in 1951 by Townes, who noted his thoughts on the back of an envelope during a period of contemplation on a bench in Franklin Park, Washington, DC.T The device was realized experimentally by Gordon, Zeiger, and Townes (1954). In this chapter, we treat the maser along the lines given by Lamb (1960). The analysis is not complicated by atomic (molecular) lifetimes, because they are long compared to the Rabi flopping time, which is the optimal transit time for molecules in the maser cavity. Furthermore, by considering single-mode, steady-state operation, we can assume by energy conservation (1) that the energy given up by the atoms due to stimulated emission is gained by the field, and (2) that this energy flow balances the cavity losses.

DOI
10.1201/9780429493515-12

Related papers

The ammonia maser

Alfred Brian Pippard

The original maser of Gordon, Zeiger and Townes, driven by a focussed stream of ammonia molecules in their antisymmetrical state, provides a conveniently explicit example on which to base a discussion of the principles underlying coherent excitation of a vibrator by stimulated emission. It was shown in chapter 18 how a quadrupole electrostatic lens served to separate symmetric from antisymmetric states, and we shall assume that separation is perfect; it is easy to extend the argument to include a proportion of molecules in the symmetric state. In addition we shall ignore any complications arising from the multitude of rotational states leading to the fine structure shown in fig. 18.8, and shall assume that only one line contributes, for example the strong 3,3 line at 23.9 GHz. Since the microwave cavity resonator, if it is to be excited by the molecules, must normally be very closely tuned to their natural frequency this assumption is realistic.

Cambridge University Press eBooks•Nov 16, 1989•0 citations

Experiments with the One-atom-maser

Linas Urbonas

There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.

•Jan 1, 2009•0 citations

Rate equations

Thomas Erneux, P. Glorieux

Modeling lasers may be realized with different levels of sophistication. Rigorously it requires a full quantum treatment but many laser dynamical properties may be captured by semiclassical or even purely classical approaches. In this book we deliberately chose the simplest point of view, i.e. purely classical equations, and try to extract analytically as much information as possible. The basic framework of our approach is provided by the rate equations . In their simplest version, they apply to an idealized active system consisting of only two energy levels coupled to a reservoir. They were introduced as soon as the laser was discovered to explain (regular or irregular, damped or undamped) intensity spikes commonly seen with solid state lasers (for a historical review, see the introduction in). These rate equations are discussed and sometimes derived from a semiclassical theory in textbooks on lasers. They capture the essential features of the response of a single-mode laser and they may be modified to account for specific effects such as the modulation of a parameter or optical feedback. The most basic processes involved in laser operation are schematically represented in Figure 1.1. N 1 and N 2 denote the number of atoms in the ground and excited levels, respectively. The process of light–matter interaction is restricted to stimulated emission and absorption.

Cambridge University Press eBooks•Apr 29, 2010•0 citations

Single- and two-mode models

Luigi A. Lugiato, Franco Prati, Massimo Brambilla

In the first section we discuss the stationary solutions for a laser with an injected signal, the active counterpart of the optical bistability analyzed in Chapter 11. Next, in Section 13.2 we consider another very interesting system, namely a laser with a saturable absorber, a free-running laser in which the optical cavity contains a passive medium in addition to the active medium. The single-mode model for this system can be constructed by combining the single-mode models for the free-running laser and for optical bistability. The discussion is then focussed on its stationary states. In Section 13.3 we return to the single-mode model for optical bistability and, by introducing an appropriate “cubic limit” on the parameters in play, we derive a cubic model for dispersive optical bistability with two-level atoms. The stationary equation for such a model formally coincides with that derived and discussed for a Kerr medium in Section 11.2. In the last section we start from the equations for a quadratic nonlinear medium in the degenerate configuration derived in Chapter 6 and combine them with the appropriate boundary conditions for the two field envelopes in play, assuming that the quadratic medium is contained in a ring cavity as happens in an optical parametric oscillator or in second-harmonic generation in a cavity. Next, by introducing the low-transmission limit and the single-mode limit we derive a two-mode model that describes the dynamics of a degenerate optical parametric oscillator or of second-harmonic generation in a cavity. Finally, for the case of a parametric oscillator we illustrate extensively the stationary solutions of the equations. A laser with an injected signal From a technical point of view, this system is interesting because of the possibility of stabilizing the frequency and the phase of separate lasers by taking advantage of the known affinity of nonlinear oscillators to lock onto a periodic forcing element. In 1972 Spencer and Lamb [125] predicted the possibility of bistable behavior in a laser with an injected signal before the surge of interest in optical bistability in the passive configuration.

Cambridge University Press eBooks•Feb 28, 2015•0 citations

On flow masers with separated emission fields

Wilfred H. U. Krause

In 1954 the invention of the ammonia molecular beam maser oscillator, through Charles Hard TOWNES and co-workers and Nikolai Gennadievich BASOV and Alexander Mikhailovich PROKHOROV, opened a new area of applied physics, the field of quantum electronics. Ten years later the importance of the invention of the new device which consists essentially of a microwave resonator and excited ammonia molecules which pass through the resonator was acknowledged by the award of the 1964 NOBEL Prize in physics to the above workers. \nSoon after the invention of the maser principle, an ammonia beam maser utilizing separated emission fields was brought into operation, a device which consists of two separated microwave resonators through which the ammonia beam maser passes in succession. It is now well known that this two-cavity variant has great practical advantages over the original one-cavity ammonia beam maser. \nHowever, not all of the macroscopic effects observed using the two-cavity ammonia beam maser could be explained in a straight­forward manner. One of the more obscure effects presents itself as follows: If the frequency of the auto-oscillation in the first resonator is detuned from one side of the possible frequency range in which generation occurs to the other then the intensity of the electromagnetic radiation in the second cavity can go through two maxima, with a gap in the middle. \nThis effect, the "double-hump detuning phenomenon", which was first observed by the Russian research group of BASOV in 1962, has since then been a challenge to several theoretical and experimental workers. BASOV and co-workers themselves made two different attempts in order to explain this phenomenon. At the Third International Conference on Quantum Electronics, held in Paris in 1963, this team reported that the effect might occur because the transition probability of the molecules passing through the second resonator depends on the degree of excitation of the first cavity. However, in 1967 BASOV and co-workers published a paper where it is suggested that the double-hump detuning phenomenon might well arise because of the interference which occurs between the emissions from molecules which move with different velocities and radiate fields with different phases. \nOn the other hand, research activities in fields other than microwave spectroscopy have made it possible to devise masers which are similar to the ammonia beam maser in that excited particles pass through a tuned resonant component, but which emit at quite different frequencies, e.g. in the audio-frequency ranee or in the mm wave range. However, up to now none of these different masers has been furnished with a successive resonator. \nIt is the purpose of this thesis to report for the first time the successful operation of a tandem maser which is not a two-cavity molecular beam maser. The author devised and investigated a maser where excited protons in water pass successively through two tuned solenoids. \nThe system is based on a conventional proton magnetometer maser oscillating in the magnetic field of the earth at a frequency near to 2 kHz. \nThe general result of the investigation is that despite \nthe enormous frequency difference (audio-frequency compared with a microwave frequency) the two coil nuclear maser behaves in much the same way as a two cavity ammonia beam maser. For the two-coil nuclear maser the double-hump detuning phenomenon can be explained \nin terms of the motion of the macroscopic nuclear magnetization, and an analysis by means of BLOCH'S equations is possible. It is shown that the double-hump detuning phenomenon is produced by a fundamental radiation process occurring in the first emission coil and 1 therefore, that it is not a second-order effect such as could occur because of the non-uniform velocity distribution of the excited particles. \nIt is also shown that for the two-resonator ammonia beam maser the detuning phenomenon can be explained in terms of quantum mechanical probabilities, when a uniform velocity distribution of the ammonia molecules is assumed. Those results agree qualitatively with the results which have been obtained using BLOCH's equations and which have been verified experimentally by means of the two-coil nuclear maser. \nA second distinctive feature of the conventional two-cavity ammonia beam maser is that if the first resonator is sufficiently detuned, generation in the second resonator can take place simultaneously at two different frequencies. The analogous effect has been observed using the two-coil nuclear maser. \nThe conventional one-coil nuclear maser which is currently used as a magnetometer has the disadvantage that it does not offer a suitable criterion for tuning the oscillation frequency accurately to the LARMOR frequency. For the two-cavity ammonia beam maser it has previously been proposed to modulate mechanically the inter-cavity distance and to use zero phase modulation as a means of tuning the maser frequency accurately to the centre frequency of the molecular transition. It is shown that by modulating mechanically the inter­coil distance of the two-coil nuclear maser. a suitable tuning criterion can be obtained in an analogous manner. A second tuning criterion is offered by the double-hump detuning phenomenon. \nIn Chapter I the maser principle is discussed using a classical model, and the different maser types which are of interest in the context of this thesis are enumerated. Chapter II contains a review of previous work on two-cavity ammonia beam masers. \nChapter III reviews the conventional theory of nuclear masers. In Chapters IV to IX the two-coil nuclear maser is investigated. Chapter X contains a general discussion of the two-resonator maser problem in terms of quantum-mechanical probabilities. Some general remarks concerning practical applications of two-resonator masers \nare made. The conclusions are summarized in a final section.

•Jan 1, 1969•0 citations

Quantum Electrodynamics of the Stimulated Emission of Radiation. I

R.M. Bevensee

The quantum electrodynamic formalism of Senitzky is developed so as to yield long-time differential equations for the time-average expectation values of electric field energy and excess molecular population in a system composed of one resonant cavity mode, two-level molecules, and a dissipation mechanism. The cavity-mode resonant frequency is essentially the mean molecular transition frequency of either a Gaussian or Lorentzian distribution of transition frequencies. The intermolecular and lattice T1 and T2 time constants are assumed to be much longer than the stimulated emission period. The field is coupled to either the electric or the magnetic dipole moments of the molecules. Senitzky's papers are summarized and the relevant expressions for the Heisenberg field and molecular operators are listed. Modified time-average expressions are obtained for the presence of a transient coherent driving field and perhaps an ``off-resonance'' molecular distribution of transition frequencies. Time averages of the derivatives of various terms in the expected field energy are compared to derivatives of time averages of those terms. Well-behaved differential equations are obtained for the time-average expectation values of field energy and molecular excess population, justified on a long-time basis by the application of an intermittent similarity transformation. A differential equation for the time-average dispersion (second moment) of electric field energy is obtained, which indicates that the relative dispersion tends to decrease during the pumping interval and increase back to the thermal value during the emission interval. Energy transfer from pumping field to molecules to the resonant field during the pumping interval is described qualitatively. The direct-product form for the density matrix ρ = ρ(field) × ρ(molecules) × ρ(dissipation mechanism) is justified by maximum-entropy inference. In conclusion, the equations of motion for the time-average expectation values of field energy and molecular population are interpreted so as to explain the envelope modulation of a solid-state laser beam during the emission period.

Journal of Mathematical Physics•Mar 1, 1964•1 citation
To treat the laser in a realistic way, we need the density matrix concepts and formalism given in Chap. 7. This material makes it possible to incorporate dipole phase decays due, for example, to collisions and to treat multimode electric fields in a straightforward way. Nevertheless, it is gratifying to find that we can already determine the field intensity for a simplified model of the ammonia beam maser, the first device of the maser-laser genre. The maser was originally conceived in 1951 by Townes, who noted his thoughts on the back of an envelope during a period of contemplation on a bench in Franklin Park, Washington, DC.T The device was realized experimentally by Gordon, Zeiger, and Townes (1954). In this chapter, we treat the maser along the lines given by Lamb (1960). The analysis is not complicated by atomic (molecular) lifetimes, because they are long compared to the Rabi flopping time, which is the optimal transit time for molecules in the maser cavity. Furthermore, by considering single-mode, steady-state operation, we can assume by energy conservation (1) that the energy given up by the atoms due to stimulated emission is gained by the field, and (2) that this energy flow balances the cavity losses.
The original maser of Gordon, Zeiger and Townes, driven by a focussed stream of ammonia molecules in their antisymmetrical state, provides a conveniently explicit example on which to base a discussion of the principles underlying coherent excitation of a vibrator by stimulated emission. It was shown in chapter 18 how a quadrupole electrostatic lens served to separate symmetric from antisymmetric states, and we shall assume that separation is perfect; it is easy to extend the argument to include a proportion of molecules in the symmetric state. In addition we shall ignore any complications arising from the multitude of rotational states leading to the fine structure shown in fig. 18.8, and shall assume that only one line contributes, for example the strong 3,3 line at 23.9 GHz. Since the microwave cavity resonator, if it is to be excited by the molecules, must normally be very closely tuned to their natural frequency this assumption is realistic.
There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.
Modeling lasers may be realized with different levels of sophistication. Rigorously it requires a full quantum treatment but many laser dynamical properties may be captured by semiclassical or even purely classical approaches. In this book we deliberately chose the simplest point of view, i.e. purely classical equations, and try to extract analytically as much information as possible. The basic framework of our approach is provided by the rate equations . In their simplest version, they apply to an idealized active system consisting of only two energy levels coupled to a reservoir. They were introduced as soon as the laser was discovered to explain (regular or irregular, damped or undamped) intensity spikes commonly seen with solid state lasers (for a historical review, see the introduction in). These rate equations are discussed and sometimes derived from a semiclassical theory in textbooks on lasers. They capture the essential features of the response of a single-mode laser and they may be modified to account for specific effects such as the modulation of a parameter or optical feedback. The most basic processes involved in laser operation are schematically represented in Figure 1.1. N 1 and N 2 denote the number of atoms in the ground and excited levels, respectively. The process of light–matter interaction is restricted to stimulated emission and absorption.
In the first section we discuss the stationary solutions for a laser with an injected signal, the active counterpart of the optical bistability analyzed in Chapter 11. Next, in Section 13.2 we consider another very interesting system, namely a laser with a saturable absorber, a free-running laser in which the optical cavity contains a passive medium in addition to the active medium. The single-mode model for this system can be constructed by combining the single-mode models for the free-running laser and for optical bistability. The discussion is then focussed on its stationary states. In Section 13.3 we return to the single-mode model for optical bistability and, by introducing an appropriate “cubic limit” on the parameters in play, we derive a cubic model for dispersive optical bistability with two-level atoms. The stationary equation for such a model formally coincides with that derived and discussed for a Kerr medium in Section 11.2. In the last section we start from the equations for a quadratic nonlinear medium in the degenerate configuration derived in Chapter 6 and combine them with the appropriate boundary conditions for the two field envelopes in play, assuming that the quadratic medium is contained in a ring cavity as happens in an optical parametric oscillator or in second-harmonic generation in a cavity. Next, by introducing the low-transmission limit and the single-mode limit we derive a two-mode model that describes the dynamics of a degenerate optical parametric oscillator or of second-harmonic generation in a cavity. Finally, for the case of a parametric oscillator we illustrate extensively the stationary solutions of the equations. A laser with an injected signal From a technical point of view, this system is interesting because of the possibility of stabilizing the frequency and the phase of separate lasers by taking advantage of the known affinity of nonlinear oscillators to lock onto a periodic forcing element. In 1972 Spencer and Lamb [125] predicted the possibility of bistable behavior in a laser with an injected signal before the surge of interest in optical bistability in the passive configuration.
In 1954 the invention of the ammonia molecular beam maser oscillator, through Charles Hard TOWNES and co-workers and Nikolai Gennadievich BASOV and Alexander Mikhailovich PROKHOROV, opened a new area of applied physics, the field of quantum electronics. Ten years later the importance of the invention of the new device which consists essentially of a microwave resonator and excited ammonia molecules which pass through the resonator was acknowledged by the award of the 1964 NOBEL Prize in physics to the above workers. \nSoon after the invention of the maser principle, an ammonia beam maser utilizing separated emission fields was brought into operation, a device which consists of two separated microwave resonators through which the ammonia beam maser passes in succession. It is now well known that this two-cavity variant has great practical advantages over the original one-cavity ammonia beam maser. \nHowever, not all of the macroscopic effects observed using the two-cavity ammonia beam maser could be explained in a straight­forward manner. One of the more obscure effects presents itself as follows: If the frequency of the auto-oscillation in the first resonator is detuned from one side of the possible frequency range in which generation occurs to the other then the intensity of the electromagnetic radiation in the second cavity can go through two maxima, with a gap in the middle. \nThis effect, the "double-hump detuning phenomenon", which was first observed by the Russian research group of BASOV in 1962, has since then been a challenge to several theoretical and experimental workers. BASOV and co-workers themselves made two different attempts in order to explain this phenomenon. At the Third International Conference on Quantum Electronics, held in Paris in 1963, this team reported that the effect might occur because the transition probability of the molecules passing through the second resonator depends on the degree of excitation of the first cavity. However, in 1967 BASOV and co-workers published a paper where it is suggested that the double-hump detuning phenomenon might well arise because of the interference which occurs between the emissions from molecules which move with different velocities and radiate fields with different phases. \nOn the other hand, research activities in fields other than microwave spectroscopy have made it possible to devise masers which are similar to the ammonia beam maser in that excited particles pass through a tuned resonant component, but which emit at quite different frequencies, e.g. in the audio-frequency ranee or in the mm wave range. However, up to now none of these different masers has been furnished with a successive resonator. \nIt is the purpose of this thesis to report for the first time the successful operation of a tandem maser which is not a two-cavity molecular beam maser. The author devised and investigated a maser where excited protons in water pass successively through two tuned solenoids. \nThe system is based on a conventional proton magnetometer maser oscillating in the magnetic field of the earth at a frequency near to 2 kHz. \nThe general result of the investigation is that despite \nthe enormous frequency difference (audio-frequency compared with a microwave frequency) the two coil nuclear maser behaves in much the same way as a two cavity ammonia beam maser. For the two-coil nuclear maser the double-hump detuning phenomenon can be explained \nin terms of the motion of the macroscopic nuclear magnetization, and an analysis by means of BLOCH'S equations is possible. It is shown that the double-hump detuning phenomenon is produced by a fundamental radiation process occurring in the first emission coil and 1 therefore, that it is not a second-order effect such as could occur because of the non-uniform velocity distribution of the excited particles. \nIt is also shown that for the two-resonator ammonia beam maser the detuning phenomenon can be explained in terms of quantum mechanical probabilities, when a uniform velocity distribution of the ammonia molecules is assumed. Those results agree qualitatively with the results which have been obtained using BLOCH's equations and which have been verified experimentally by means of the two-coil nuclear maser. \nA second distinctive feature of the conventional two-cavity ammonia beam maser is that if the first resonator is sufficiently detuned, generation in the second resonator can take place simultaneously at two different frequencies. The analogous effect has been observed using the two-coil nuclear maser. \nThe conventional one-coil nuclear maser which is currently used as a magnetometer has the disadvantage that it does not offer a suitable criterion for tuning the oscillation frequency accurately to the LARMOR frequency. For the two-cavity ammonia beam maser it has previously been proposed to modulate mechanically the inter-cavity distance and to use zero phase modulation as a means of tuning the maser frequency accurately to the centre frequency of the molecular transition. It is shown that by modulating mechanically the inter­coil distance of the two-coil nuclear maser. a suitable tuning criterion can be obtained in an analogous manner. A second tuning criterion is offered by the double-hump detuning phenomenon. \nIn Chapter I the maser principle is discussed using a classical model, and the different maser types which are of interest in the context of this thesis are enumerated. Chapter II contains a review of previous work on two-cavity ammonia beam masers. \nChapter III reviews the conventional theory of nuclear masers. In Chapters IV to IX the two-coil nuclear maser is investigated. Chapter X contains a general discussion of the two-resonator maser problem in terms of quantum-mechanical probabilities. Some general remarks concerning practical applications of two-resonator masers \nare made. The conclusions are summarized in a final section.
The quantum electrodynamic formalism of Senitzky is developed so as to yield long-time differential equations for the time-average expectation values of electric field energy and excess molecular population in a system composed of one resonant cavity mode, two-level molecules, and a dissipation mechanism. The cavity-mode resonant frequency is essentially the mean molecular transition frequency of either a Gaussian or Lorentzian distribution of transition frequencies. The intermolecular and lattice T1 and T2 time constants are assumed to be much longer than the stimulated emission period. The field is coupled to either the electric or the magnetic dipole moments of the molecules. Senitzky's papers are summarized and the relevant expressions for the Heisenberg field and molecular operators are listed. Modified time-average expressions are obtained for the presence of a transient coherent driving field and perhaps an ``off-resonance'' molecular distribution of transition frequencies. Time averages of the derivatives of various terms in the expected field energy are compared to derivatives of time averages of those terms. Well-behaved differential equations are obtained for the time-average expectation values of field energy and molecular excess population, justified on a long-time basis by the application of an intermittent similarity transformation. A differential equation for the time-average dispersion (second moment) of electric field energy is obtained, which indicates that the relative dispersion tends to decrease during the pumping interval and increase back to the thermal value during the emission interval. Energy transfer from pumping field to molecules to the resonant field during the pumping interval is described qualitatively. The direct-product form for the density matrix ρ = ρ(field) × ρ(molecules) × ρ(dissipation mechanism) is justified by maximum-entropy inference. In conclusion, the equations of motion for the time-average expectation values of field energy and molecular population are interpreted so as to explain the envelope modulation of a solid-state laser beam during the emission period.