The original maser of Gordon, Zeiger and Townes, driven by a focussed stream of ammonia molecules in their antisymmetrical state, provides a conveniently explicit example on which to base a discussion of the principles underlying coherent excitation of a vibrator by stimulated emission. It was shown in chapter 18 how a quadrupole electrostatic lens served to separate symmetric from antisymmetric states, and we shall assume that separation is perfect; it is easy to extend the argument to include a proportion of molecules in the symmetric state. In addition we shall ignore any complications arising from the multitude of rotational states leading to the fine structure shown in fig. 18.8, and shall assume that only one line contributes, for example the strong 3,3 line at 23.9 GHz. Since the microwave cavity resonator, if it is to be excited by the molecules, must normally be very closely tuned to their natural frequency this assumption is realistic.
The original maser of Gordon, Zeiger and Townes, driven by a focussed stream of ammonia molecules in their antisymmetrical state, provides a conveniently explicit example on which to base a discussion of the principles underlying coherent excitation of a vibrator by stimulated emission. It was shown in chapter 18 how a quadrupole electrostatic lens served to separate symmetric from antisymmetric states, and we shall assume that separation is perfect; it is easy to extend the argument to include a proportion of molecules in the symmetric state. In addition we shall ignore any complications arising from the multitude of rotational states leading to the fine structure shown in fig. 18.8, and shall assume that only one line contributes, for example the strong 3,3 line at 23.9 GHz. Since the microwave cavity resonator, if it is to be excited by the molecules, must normally be very closely tuned to their natural frequency this assumption is realistic.
To treat the laser in a realistic way, we need the density matrix concepts and formalism given in Chap. 7. This material makes it possible to incorporate dipole phase decays due, for example, to collisions and to treat multimode electric fields in a straightforward way. Nevertheless, it is gratifying to find that we can already determine the field intensity for a simplified model of the ammonia beam maser, the first device of the maser-laser genre. The maser was originally conceived in 1951 by Townes, who noted his thoughts on the back of an envelope during a period of contemplation on a bench in Franklin Park, Washington, DC.T The device was realized experimentally by Gordon, Zeiger, and Townes (1954). In this chapter, we treat the maser along the lines given by Lamb (1960). The analysis is not complicated by atomic (molecular) lifetimes, because they are long compared to the Rabi flopping time, which is the optimal transit time for molecules in the maser cavity. Furthermore, by considering single-mode, steady-state operation, we can assume by energy conservation (1) that the energy given up by the atoms due to stimulated emission is gained by the field, and (2) that this energy flow balances the cavity losses.
In 1954 the invention of the ammonia molecular beam maser oscillator, through Charles Hard TOWNES and co-workers and Nikolai Gennadievich BASOV and Alexander Mikhailovich PROKHOROV, opened a new area of applied physics, the field of quantum electronics. Ten years later the importance of the invention of the new device which consists essentially of a microwave resonator and excited ammonia molecules which pass through the resonator was acknowledged by the award of the 1964 NOBEL Prize in physics to the above workers. \nSoon after the invention of the maser principle, an ammonia beam maser utilizing separated emission fields was brought into operation, a device which consists of two separated microwave resonators through which the ammonia beam maser passes in succession. It is now well known that this two-cavity variant has great practical advantages over the original one-cavity ammonia beam maser. \nHowever, not all of the macroscopic effects observed using the two-cavity ammonia beam maser could be explained in a straightforward manner. One of the more obscure effects presents itself as follows: If the frequency of the auto-oscillation in the first resonator is detuned from one side of the possible frequency range in which generation occurs to the other then the intensity of the electromagnetic radiation in the second cavity can go through two maxima, with a gap in the middle. \nThis effect, the "double-hump detuning phenomenon", which was first observed by the Russian research group of BASOV in 1962, has since then been a challenge to several theoretical and experimental workers. BASOV and co-workers themselves made two different attempts in order to explain this phenomenon. At the Third International Conference on Quantum Electronics, held in Paris in 1963, this team reported that the effect might occur because the transition probability of the molecules passing through the second resonator depends on the degree of excitation of the first cavity. However, in 1967 BASOV and co-workers published a paper where it is suggested that the double-hump detuning phenomenon might well arise because of the interference which occurs between the emissions from molecules which move with different velocities and radiate fields with different phases. \nOn the other hand, research activities in fields other than microwave spectroscopy have made it possible to devise masers which are similar to the ammonia beam maser in that excited particles pass through a tuned resonant component, but which emit at quite different frequencies, e.g. in the audio-frequency ranee or in the mm wave range. However, up to now none of these different masers has been furnished with a successive resonator. \nIt is the purpose of this thesis to report for the first time the successful operation of a tandem maser which is not a two-cavity molecular beam maser. The author devised and investigated a maser where excited protons in water pass successively through two tuned solenoids. \nThe system is based on a conventional proton magnetometer maser oscillating in the magnetic field of the earth at a frequency near to 2 kHz. \nThe general result of the investigation is that despite \nthe enormous frequency difference (audio-frequency compared with a microwave frequency) the two coil nuclear maser behaves in much the same way as a two cavity ammonia beam maser. For the two-coil nuclear maser the double-hump detuning phenomenon can be explained \nin terms of the motion of the macroscopic nuclear magnetization, and an analysis by means of BLOCH'S equations is possible. It is shown that the double-hump detuning phenomenon is produced by a fundamental radiation process occurring in the first emission coil and 1 therefore, that it is not a second-order effect such as could occur because of the non-uniform velocity distribution of the excited particles. \nIt is also shown that for the two-resonator ammonia beam maser the detuning phenomenon can be explained in terms of quantum mechanical probabilities, when a uniform velocity distribution of the ammonia molecules is assumed. Those results agree qualitatively with the results which have been obtained using BLOCH's equations and which have been verified experimentally by means of the two-coil nuclear maser. \nA second distinctive feature of the conventional two-cavity ammonia beam maser is that if the first resonator is sufficiently detuned, generation in the second resonator can take place simultaneously at two different frequencies. The analogous effect has been observed using the two-coil nuclear maser. \nThe conventional one-coil nuclear maser which is currently used as a magnetometer has the disadvantage that it does not offer a suitable criterion for tuning the oscillation frequency accurately to the LARMOR frequency. For the two-cavity ammonia beam maser it has previously been proposed to modulate mechanically the inter-cavity distance and to use zero phase modulation as a means of tuning the maser frequency accurately to the centre frequency of the molecular transition. It is shown that by modulating mechanically the intercoil distance of the two-coil nuclear maser. a suitable tuning criterion can be obtained in an analogous manner. A second tuning criterion is offered by the double-hump detuning phenomenon. \nIn Chapter I the maser principle is discussed using a classical model, and the different maser types which are of interest in the context of this thesis are enumerated. Chapter II contains a review of previous work on two-cavity ammonia beam masers. \nChapter III reviews the conventional theory of nuclear masers. In Chapters IV to IX the two-coil nuclear maser is investigated. Chapter X contains a general discussion of the two-resonator maser problem in terms of quantum-mechanical probabilities. Some general remarks concerning practical applications of two-resonator masers \nare made. The conclusions are summarized in a final section.
The equations are generalized governing coherent emission from quantum mechanical amplifiers (microwave, infrared, and optical masers) using either electric or magnetic dipole transitions. Earlier analyses by Gordon, Zeiger and Townes, Feynman, Vernon and Hellworth, and Wang and Singer, are incorporated in this generalization. The principal new result of this analysis is that an amplitude modulation of the output is to be expected from all maser oscillators excepting those in which excited atoms are supplied at a notably greater rate than the depopulation rate due to coherent induced emission. This analysis also suggests that an energy population inversion of electric dipole moments can be performed using coherent light sources in the same manner as with magnetic dipole moments. It appears therefore that modulation of an optical or infrared maser (e.g., for communication purposes) may be easily accomplished by varying the population of excited states through control of the pumping energy. This modulation may be both by absorption and amplification. (Author)
A unidirectional quantum-mechanical amplifier has been developed in which the amplifying medium consists of a beam of ammonia molecules passing through, in turn, two separated resonant cavities. The cavities are electrically isolated from one another so that the only coupling is provided by the molecular beam. Unlike the various single-cavity amplifiers constructed in other laboratories, in which a common coupling point for input and output signals necessitates the inclusion of isolators or circulators to separate the two signals, the amplifier described herein affords a natural isolation of input and output with independent control of loadings. After a discussion of the physical principles underlying the mechanism of amplification in a two-cavity molecular beam amplifier, a simplified theory of the operation of the two-cavity amplifier is presented, outlining the parameters which influence power gain and noise Figure. The details of an experimental amplifier are described and the results of gain and noise figure measurements are reported.
The subject of masers is introduced by giving an historical account of events which led to the amplification of microwave radiation by an inverted population in a system of weakly interacting ammonia molecules. The introduction also outlines the development of masers up to the present. Sections 2 and 3 are concerned with maser fundamentals. Methods for obtaining inverted populations are discussed in § 2. Section 3 is devoted to the theory of maser gain and noise. This is followed by a discussion of microwave solid state masers. Microwave maser materials and the development of unidirectional travelling wave maser amplifiers are emphasized. Optical masers are treated in § 5. In this section the theory of optical amplifiers and oscillators is outlined. Also included in the theoretical discussion is a rather lengthy consideration of pump power requirements in optically pumped masers. This is followed by a survey of solid state, semiconductor and gaseous optical masers. The review ends with some comments on the extension of masers to new wavelength regions.
Maser action due to a mixing between unperturbed spin states, which is produced by a strong coherent pumping field at an angular frequency ω, is investigated by using rate equations of a spin density matrix referred to a rotating coordinate system. The relaxation of each state, which was introduced usually by phenomenological considerations, is obtained from an interaction Hamiltonian of the spin moments with local fields. The induced oscillating fields at 2ω±ω s and ω s , which are proportional to a small signal field at a frequency ω s , have the possibility of power emission (or absorption) by choosing suitably the pumping field. The components at 2ω±ω s are responsible for a frequency mixing between ω and ω±ω s occuring in the rotating coordinates. The emitted (or absorbed) line shape is not a simple Lorentzian in the case of the spin moment 1×ℏ and considered to be a quantum affect in the three level scheme. The frequencies of the emitted (or absorbed) fields are expected to be shifted by varying the magnitude, or the frequency of the pumping field, or the static magnetic field.