Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Effects of wave-front tilt and air density fluctuations in a sensitive atom interferometry gyroscope

Wenjie Xu, Ling Cheng, Jie Liu, Cheng Zhang, Ke Zhang, Yuan Sheng Cheng, Zhi Qiang Gao, Lushuai Cao, Xiao‐Chun Duan, Min-Kang Zhou, Zhong-Kun Hu

Published Apr 1, 2020• 22 citations
Publisher

Abstract

. The atom interferometry gyroscope is driven by a π/2 - π - π - π/2 Raman pulse sequence based on an atom fountain with a parabolic trajectory. The phase-locked laser beams for Raman transitions partly propagate outside of the vacuum chamber and expose to the air when passing through the two arms of the vacuum chamber. This configuration leads to the tilt of the laser's wave-front and suffers the fluctuation of air density. The impacts on both the fringe contrast and long-term stability are experimentally investigated in detail, and effective schemes are developed to improve the performance of our atom gyroscope. The method presented here could be useful for developing large atom interferometry facilities with separated vacuum chambers.

DOI
10.1364/oe.391780

Related papers

Limits on the sensitivity of a cold atom interferometry gyroscope

Wenjie Xu, Lele Chen, Ming-Jie Nie +2 more

We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.

Optics Express•Oct 28, 2024•7 citations

High-performance gyroscope for rotational seismology.

Nathan Marliere, Mohamed Guessoum, Rémi Geiger +1 more

The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.

•Sep 5, 2023•0 citations

Calibration of atomic trajectories in a large-area dual-atom-interferometer gyroscope

Zhan-Wei Yao, Si-Bin Lu, Runbing Li +3 more

We propose and demonstrate a method for calibrating atomic trajectories in a large-area dual-atom-interferometer gyroscope. The atom trajectories are monitored by modulating and delaying the Raman transition, and they are precisely calibrated by controlling the laser orientation and the bias magnetic field. To improve the immunity to the gravity effect and the common phase noise, the symmetry and the overlap of two large-area atomic interference loops are optimized by calibrating the atomic trajectories and by aligning the Raman-laser orientations. The dual-atom-interferometer gyroscope is applied in the measurement of the Earth's rotation. The sensitivity is $1.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ rad $\mathrm{s}{}^{\ensuremath{-}1}$ ${\text{Hz}}^{\ensuremath{-}1/2}$, and the long-term stability is $6.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ rad/s at 2000 s.

arXiv:1711.05872•Physical Review A•Jan 17, 2018•32 citations

CHARACTERIZATION OF A COLD ATOM GYROSCOPE

Arnaud Landragin, A. Gauguet, Thomas Lévèque +1 more

We present the evaluation of the performances of our cold atom gyroscope. The gyroscope is based on two cold Cesium atom sources, which are manipulated thanks to Raman transitions. We show that the short term sensitivity is limited by the quantum projection noise and the long term sensitivity by wave front distortion of the Raman lasers. A study of the bias and scaling factor completes the characterization of the sensor.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Coriolis effect due to laser beam tilting in an atom interferometer

Li Li, Lele Chen, Qin Luo +3 more

The Coriolis effect can introduce significant systematic errors in atom interferometers. This study examines the coupling effect between the Coriolis effect and the Raman beams–orientation in a fountain atomic gravimeter. Theoretical analysis indicates that the Coriolis effect is correlated with the orientation of the Raman beams, and tilt modulation experiments were conducted to substantiate this correlation. Furthermore, by aligning the orientations of the atomic fountain, the vacuum chamber, and the Raman mirror, we achieved simultaneous suppression of both the Coriolis effect and the tilt effect to sub- μ Gal levels in a high-precision atomic gravimeter. This work offers guidance on assessing systematic errors in high-precision atomic gravimeters.

Optics Express•Dec 17, 2024•3 citations

Multi-axis atom interferometer gyroscope with a single source of atoms

Yun-Jhih Chen, Azure Hansen, Gregory W. Hoth +4 more

Using the technique of point source atom interferometry, we characterize the sensitivity of a multi-axis gyroscope based on free-space Raman interrogation of a single source of cold atoms in a glass vacuum cell. The instrument simultaneously measures the acceleration in the direction of the Raman laser beams and the component of the rotation vector in the plane perpendicular to that direction. We characterize the sensitivities for the magnitude and direction of the rotation vector measurement, which are 0.033 $^{\circ}/\mathrm{s}$ and 0.27 $^{\circ}$ with one second averaging time, respectively. The sensitivity could be improved by increasing the Raman interrogation time, allowing the cold-atom cloud to expand further, correcting the fluctuations in the initial cloud shape, and reducing sources of technical noise. The unique ability of the PSI technique to measure the rotation vector in a plane may permit applications of atom interferometry such as tracking the precession of a rotation vector and gyrocompassing.

arXiv:1812.00106•Dec 1, 2018•13 citations
. The atom interferometry gyroscope is driven by a π/2 - π - π - π/2 Raman pulse sequence based on an atom fountain with a parabolic trajectory. The phase-locked laser beams for Raman transitions partly propagate outside of the vacuum chamber and expose to the air when passing through the two arms of the vacuum chamber. This configuration leads to the tilt of the laser's wave-front and suffers the fluctuation of air density. The impacts on both the fringe contrast and long-term stability are experimentally investigated in detail, and effective schemes are developed to improve the performance of our atom gyroscope. The method presented here could be useful for developing large atom interferometry facilities with separated vacuum chambers.
We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.
The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.
We propose and demonstrate a method for calibrating atomic trajectories in a large-area dual-atom-interferometer gyroscope. The atom trajectories are monitored by modulating and delaying the Raman transition, and they are precisely calibrated by controlling the laser orientation and the bias magnetic field. To improve the immunity to the gravity effect and the common phase noise, the symmetry and the overlap of two large-area atomic interference loops are optimized by calibrating the atomic trajectories and by aligning the Raman-laser orientations. The dual-atom-interferometer gyroscope is applied in the measurement of the Earth's rotation. The sensitivity is $1.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ rad $\mathrm{s}{}^{\ensuremath{-}1}$ ${\text{Hz}}^{\ensuremath{-}1/2}$, and the long-term stability is $6.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ rad/s at 2000 s.
The Coriolis effect can introduce significant systematic errors in atom interferometers. This study examines the coupling effect between the Coriolis effect and the Raman beams–orientation in a fountain atomic gravimeter. Theoretical analysis indicates that the Coriolis effect is correlated with the orientation of the Raman beams, and tilt modulation experiments were conducted to substantiate this correlation. Furthermore, by aligning the orientations of the atomic fountain, the vacuum chamber, and the Raman mirror, we achieved simultaneous suppression of both the Coriolis effect and the tilt effect to sub- μ Gal levels in a high-precision atomic gravimeter. This work offers guidance on assessing systematic errors in high-precision atomic gravimeters.
Using the technique of point source atom interferometry, we characterize the sensitivity of a multi-axis gyroscope based on free-space Raman interrogation of a single source of cold atoms in a glass vacuum cell. The instrument simultaneously measures the acceleration in the direction of the Raman laser beams and the component of the rotation vector in the plane perpendicular to that direction. We characterize the sensitivities for the magnitude and direction of the rotation vector measurement, which are 0.033 ∘/s^{\circ}/\mathrm{s}∘/s and 0.27 ∘^{\circ}∘ with one second averaging time, respectively. The sensitivity could be improved by increasing the Raman interrogation time, allowing the cold-atom cloud to expand further, correcting the fluctuations in the initial cloud shape, and reducing sources of technical noise. The unique ability of the PSI technique to measure the rotation vector in a plane may permit applications of atom interferometry such as tracking the precession of a rotation vector and gyrocompassing.