Optics Express

Limits on the sensitivity of a cold atom interferometry gyroscope

Wenjie Xu, Lele Chen, Ming-Jie Nie, Min-Kang Zhou, Zhong-Kun Hu

Published Oct 28, 2024• 7 citations
Publisher

Abstract

We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.

DOI
10.1364/oe.538453

Related papers

Characterization and limits of a cold-atom Sagnac interferometer

A. Gauguet, B. Canuel, Thomas Lévèque +2 more

We present the full evaluation of a cold-atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal, allowing us to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generation of ultrasensitive atom gyroscopes.

arXiv:0907.2580•Physical Review A•Dec 1, 2009•220 citations

High-performance gyroscope for rotational seismology.

Nathan Marliere, Mohamed Guessoum, Rémi Geiger +1 more

The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.

•Sep 5, 2023•0 citations

Performance of a point source atom interferometer gyroscope

Azure Hansen, Yun Chen, M. Shuker +6 more

Point source atom interferometry, employing optical Raman pulses and a cold atom source, enables measurements of rotation and acceleration in a compact experimental package. This system is uniquely sensitive to rotations in the plane perpendicular to the Raman beamline. Here we discuss our experiment’s sensitivity, stability, systematic errors, and other performance-limiting factors both fundamentaland technical. Our current measurements for the sensitivity to the magnitude and direction of the rotation vector are 0.6 mrad/s and 5 mrad, respectively.

•Apr 14, 2019•0 citations

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Denis Savoie, Matteo Altorio, Bess Fang +2 more

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Matteo Altorio, Denis Savoie, Bess Fang +2 more

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

•Sep 26, 2017•0 citations

Multi-axis atom interferometer gyroscope with a single source of atoms

Yun-Jhih Chen, Azure Hansen, Gregory W. Hoth +4 more

Using the technique of point source atom interferometry, we characterize the sensitivity of a multi-axis gyroscope based on free-space Raman interrogation of a single source of cold atoms in a glass vacuum cell. The instrument simultaneously measures the acceleration in the direction of the Raman laser beams and the component of the rotation vector in the plane perpendicular to that direction. We characterize the sensitivities for the magnitude and direction of the rotation vector measurement, which are 0.033 $^{\circ}/\mathrm{s}$ and 0.27 $^{\circ}$ with one second averaging time, respectively. The sensitivity could be improved by increasing the Raman interrogation time, allowing the cold-atom cloud to expand further, correcting the fluctuations in the initial cloud shape, and reducing sources of technical noise. The unique ability of the PSI technique to measure the rotation vector in a plane may permit applications of atom interferometry such as tracking the precession of a rotation vector and gyrocompassing.

arXiv:1812.00106•Dec 1, 2018•13 citations
We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.
We present the full evaluation of a cold-atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal, allowing us to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generation of ultrasensitive atom gyroscopes.
The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.
Point source atom interferometry, employing optical Raman pulses and a cold atom source, enables measurements of rotation and acceleration in a compact experimental package. This system is uniquely sensitive to rotations in the plane perpendicular to the Raman beamline. Here we discuss our experiment’s sensitivity, stability, systematic errors, and other performance-limiting factors both fundamentaland technical. Our current measurements for the sensitivity to the magnitude and direction of the rotation vector are 0.6 mrad/s and 5 mrad, respectively.
Using the technique of point source atom interferometry, we characterize the sensitivity of a multi-axis gyroscope based on free-space Raman interrogation of a single source of cold atoms in a glass vacuum cell. The instrument simultaneously measures the acceleration in the direction of the Raman laser beams and the component of the rotation vector in the plane perpendicular to that direction. We characterize the sensitivities for the magnitude and direction of the rotation vector measurement, which are 0.033 ∘/s^{\circ}/\mathrm{s}∘/s and 0.27 ∘^{\circ}∘ with one second averaging time, respectively. The sensitivity could be improved by increasing the Raman interrogation time, allowing the cold-atom cloud to expand further, correcting the fluctuations in the initial cloud shape, and reducing sources of technical noise. The unique ability of the PSI technique to measure the rotation vector in a plane may permit applications of atom interferometry such as tracking the precession of a rotation vector and gyrocompassing.