Bulletin of the Lebedev Physics Institute

Three-Dimensional Paul Trap with High Secular Frequency for Compact Optical Clock

Ilya A. Semerikov, Ilia V. Zalivako, Alexander S. Borisenko, Mikhail A. Aksenov, Pavel Vishnyakov, Pavel Sidorov, Н. Н. Колачевский, Ksenia Yu. Khabarova

Published Sep 1, 2019• 2 citations
Publisher

Abstract

The Paul ion trap is developed for the use in a compact frequency standard based on a single ytterbium ion. The design features are the use of atomic ovens for compensating for parasitic electric fields and good optical accessibility. The results on trapping and laser cooling of a single 171 Yb+ ion are presented. A secular frequency of up to 1.2 MHz has been achieved.

DOI
10.3103/s1068335619090070

Related papers

Compact Yb+optical atomic clock project: design principle and current status

Clément Lacroûte, Maël Souidi, Pierre-Yves Bourgeois +6 more

We present the design of a compact optical clock based on the 2 S 1/2 → 2 D 3/2 435.5 nm transition in 171 Yb + . The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred μ m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.

arXiv:1603.05816•Journal of Physics Conference Series•Jun 1, 2016•24 citations

Evaluation of trap-induced systematic frequency shifts for a multi-ion optical clock at the 10−19level

Jonas Keller, T. Burgermeister, Dimitri Kalincev +2 more

In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .

arXiv:1512.05677•Journal of Physics Conference Series•Jun 1, 2016•29 citations

Paul trap for optical frequency standards

Steven R. Jefferts, Christopher R. Monroe, A. S. Barton +1 more

We describe a variant of the quadrupole rf (Paul) ion trap capable of localization of a trapped ion within much less than an optical wavelength (Lamb-Dicke regime). Attainment of the Lamb-Dicke regime reduces the sensitivity of the central absorption feature to atomic motion, thereby reducing an important source of noise in an optical frequency standard. The trapping potentials are generated by a high-Q, vacuum-compatible, quarter-wave resonator driven at about 240 MHz. Secular frequencies of tens of megahertz have been achieved for trapped magnesium and beryllium ions.>

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1995•7 citations

Towards an optical frequency standard based on a single Ca/sup +/ ion in a miniature trap

Martina Knoop, Mustapha Said Herbane, M. Houssin +2 more

Summary form only given. Among the ions proposed for a frequency standard in the optical domain, Ca/sup +/ is one of the most favorable candidates due to its wavelengths accessible with all-solid-state laser systems. This allows to imagine an ultimate experimental setup being simple and compact. The 4S/sub 1/2/-3D/sub 5/2/ electric quadrupole transition at 729 nm with a natural linewidth below 1 Hz serves as clock transition, while laser cooling on one of the resonance lines is carried out at 397 nm. To obtain the small spectral linewidths necessary for a frequency standard performance, it is essential to reduce the residual Doppler broadening caused by the RF heating in the Paul trap. The first-order Doppler broadening of a single ion can be eliminated in the Lamb-Dicke regime where the ion's amplitude of motion is inferior to the emitted wavelength. The main condition for the access of this frequency modulation regime is a high motional frequency of the trapped ion. This is more easily obtained in a low capacitance device and thus traps with reduced dimensions are required. We have set up a miniature ion trap of the Paul-Straubel-type. The stored ions are observed by a photomultiplier in the photon-counting mode as well as by an intensified CCD camera, permitting the visualization of their spatial behavior. Laser cooling of the Ca/sup +/ ions is carried out on the 4S/sub 1/2/-4P/sup 1/2/ resonance line at 397 nm. Progress on the characterization of the trapped single ion as well as on the generation of the involved wavelengths exclusively by solid-state lasers is reported.

Conference on Lasers and Electro-Optics•Aug 29, 2005•0 citations

An Active Ion Optical Clock

Wei Zhuang, Tong-Gang Zhang, Jingbiao Chen

We propose a scheme for an active ion optical clock with a detailed description of the pumping method, lasing states, output power, linewidth and light shift. Considering 171 Yb + ions in a Paul trap, we propose utilizing a Fabry—Perot resonator to realize the lasing of active optical frequency standards. The quantum-limited linewidth of an active 171 Yb + ion optical clock is narrower than 1 mHz. Based on the mechanism and the advantages of an active optical clock at the ion optical clock transition frequency, this new laser light source as a stable local oscillator will be beneficial to the single-ion optical clock, which currently is one of the most accurate clocks.

Chinese Physics Letters•Sep 1, 2014•8 citations

Towards a Transportable Optical Frequency Standard Based on a Single Yb+ Ion

Y. H. Zheng, Yiting Chen, S. N. Miao +8 more

SummaryThe optical clock based on trapped ions has attracted great interest due to the important significance in fundamental physics and application prospects in metrology of time and frequency. The ytterbium ion has unique advantages in developing transportable and miniaturized optical clocks because it has long storage time and its related laser system is compact. In addition, the171Yb+ion has two clock transition lines, which can perform frequency self-comparison. This paper mainly introduces the progress in the development of the transportable optical clock system based on the single171Yb+ion at Tsinghua University, China. A transportable physical package, including the vacuum system, optic system and imaging system is presented and implemented to automatically detect the presence of trapped ion.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 12, 2025•1 citation
The Paul ion trap is developed for the use in a compact frequency standard based on a single ytterbium ion. The design features are the use of atomic ovens for compensating for parasitic electric fields and good optical accessibility. The results on trapping and laser cooling of a single 171 Yb+ ion are presented. A secular frequency of up to 1.2 MHz has been achieved.
We present the design of a compact optical clock based on the 2 S 1/2 → 2 D 3/2 435.5 nm transition in 171 Yb + . The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred μ m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.
In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .
We describe a variant of the quadrupole rf (Paul) ion trap capable of localization of a trapped ion within much less than an optical wavelength (Lamb-Dicke regime). Attainment of the Lamb-Dicke regime reduces the sensitivity of the central absorption feature to atomic motion, thereby reducing an important source of noise in an optical frequency standard. The trapping potentials are generated by a high-Q, vacuum-compatible, quarter-wave resonator driven at about 240 MHz. Secular frequencies of tens of megahertz have been achieved for trapped magnesium and beryllium ions.>
Summary form only given. Among the ions proposed for a frequency standard in the optical domain, Ca/sup +/ is one of the most favorable candidates due to its wavelengths accessible with all-solid-state laser systems. This allows to imagine an ultimate experimental setup being simple and compact. The 4S/sub 1/2/-3D/sub 5/2/ electric quadrupole transition at 729 nm with a natural linewidth below 1 Hz serves as clock transition, while laser cooling on one of the resonance lines is carried out at 397 nm. To obtain the small spectral linewidths necessary for a frequency standard performance, it is essential to reduce the residual Doppler broadening caused by the RF heating in the Paul trap. The first-order Doppler broadening of a single ion can be eliminated in the Lamb-Dicke regime where the ion's amplitude of motion is inferior to the emitted wavelength. The main condition for the access of this frequency modulation regime is a high motional frequency of the trapped ion. This is more easily obtained in a low capacitance device and thus traps with reduced dimensions are required. We have set up a miniature ion trap of the Paul-Straubel-type. The stored ions are observed by a photomultiplier in the photon-counting mode as well as by an intensified CCD camera, permitting the visualization of their spatial behavior. Laser cooling of the Ca/sup +/ ions is carried out on the 4S/sub 1/2/-4P/sup 1/2/ resonance line at 397 nm. Progress on the characterization of the trapped single ion as well as on the generation of the involved wavelengths exclusively by solid-state lasers is reported.
We propose a scheme for an active ion optical clock with a detailed description of the pumping method, lasing states, output power, linewidth and light shift. Considering 171 Yb + ions in a Paul trap, we propose utilizing a Fabry—Perot resonator to realize the lasing of active optical frequency standards. The quantum-limited linewidth of an active 171 Yb + ion optical clock is narrower than 1 mHz. Based on the mechanism and the advantages of an active optical clock at the ion optical clock transition frequency, this new laser light source as a stable local oscillator will be beneficial to the single-ion optical clock, which currently is one of the most accurate clocks.
SummaryThe optical clock based on trapped ions has attracted great interest due to the important significance in fundamental physics and application prospects in metrology of time and frequency. The ytterbium ion has unique advantages in developing transportable and miniaturized optical clocks because it has long storage time and its related laser system is compact. In addition, the171Yb+ion has two clock transition lines, which can perform frequency self-comparison. This paper mainly introduces the progress in the development of the transportable optical clock system based on the single171Yb+ion at Tsinghua University, China. A transportable physical package, including the vacuum system, optic system and imaging system is presented and implemented to automatically detect the presence of trapped ion.