arXiv:1603.05816 · Journal of Physics Conference Series

Compact Yb+optical atomic clock project: design principle and current status

Clément Lacroûte, Maël Souidi, Pierre-Yves Bourgeois, Jacques Millo, Khaldoun Saleh, Emmanuel Bigler, Rodolphe Boudot, V. Giordano, Y. Kersalé

Published Jun 1, 2016• 24 citations
arXivHTMLPDF

Abstract

We present the design of a compact optical clock based on the 2 S 1/2 → 2 D 3/2 435.5 nm transition in 171 Yb + . The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred μ m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.

DOI
10.1088/1742-6596/723/1/012025

Related papers

Progress on a Surface-Electrode Ion Trap for Optical Frequency Metrology

Marion Delehaye, Y. Kersalé, Clément Lacroûte +8 more

We present our latest results obtained with a surface-electrode ion trap designed for optical frequency metrology. A prototype trap, based on a simple geometry realized on a printed-circuit board, has been successfully used to trap single Yb+ions. Our long-term goal is the realization of a compact single-ion optical clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

Micro Ion Frequency Standard

Peter D. D. Schwindt, Roy H. Olsson, K.E. Wojciechowski +7 more

We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.

•Nov 19, 2009•2 citations

Development of (Miniaturized) Trapped Yb Ion Clocks.

Peter D. D. Schwindt

Outline • Introduction• Why trapped ions for miniaturization?• Miniaturized vacuum package: 1 cm 3 • Pulsed-mode ion clock performance • F-state trapping • Current focus: microwave optical double resonance continuous operation • Alternative ion clock: Alkali Mediated Atomic Clock • Conclusion Miniaturization with Long-Term and Environmental Stability • Achieve Cs Beam Clock performance in a mass and power constrained package • DARPA programs: • IMPACT: improved long-term stability • ACES: improved environmental stability Applications--Excellent timing for: • Rapid GPS acquisition, and GPS denied navigation and timing • Nano/pico (cube) satellites • Pulsed radio and spread spectrum communications Microsemi 5071A Miniature primary frequency standard Approved for Public Release, Distribution Unlimited Critical Elements of the 171 Yb + Clock Trap Electrodes Ions Yb Source Vacuum Package Control and Power Electronics Local Oscillator Magnetic Shield and Coil Repump (935 nm) Optical Pumping/ State Detection Laser (369 nm) Beam Combiner Fluorescence Collection Lens Fluorescence Detector Photo Multiplier Tube (PMT) Ionization UV Light

•Dec 12, 2018•0 citations

Heating rate measurements in a prototype surface-electrode trap for optical frequency metrology

Clément Lacroûte, T. Lauprêtre, Bachir Achi +4 more

In this talk, I will review our recent work on the development of a compact, optical atomic clock based on trapped Yb+ ions. We have developed a simple surface-electrodes microtrap designed towards optical frequency metrology. After reviewing the advantages of microtraps for single-ion optical clocks, I will show our experimental results of heating rate measurements with a simple prototype trap.

•Jun 20, 2022•0 citations

Single ion spectroscopy for optical clocks

Chr. Tamm, E. Peik, T. Schneider +5 more

The 435 mum171Yb+transition is a good candidate for an atomic clock based on an optical transition. We have stored single171Yb ions for several months in RF traps. The ions are cooled, repumped and the clock transition is interrogated by (frequency-doubled) diode lasers. The interrogation laser linewidth was 30 Hz determining the resolvable linewidth of the Yb+transition interrogated. The absolute frequency of this transition was measured using an optical comb generator, self referenced by broadening the spectrum to above one octave, with respect to a Cs fountain clock. Of all systematic frequency shifts to which this transition is subject an estimate indicates that the electric quadruple shift appears is the largest. To obtain a magnitude of the quadruple shift (and the quadruple moment) the clock frequencies of two independently stored and cooled171Yb ions were compared while varying the static electric field in one trap. The measured frequency shift amounting to ~1 Hz/V. This result would seem to permit clocks with much higher accuracy than the clocks based on microwave transition, particularly if the technique of aligning the ions with respect to the electric field were applicable. Anticipating even more precise clocks, we are presently investigating a blue nuclear transition in229Th. Such a nuclear transition should be even better shielded from environmental influences than transitions in the electron shell. This nuclear transition has not yet been directly optically observed. We are presently investigating the luminescence after incoherent broad band optical excitation. The triply ionized223Th is then a suitable system for trapped single ion spectroscopy. The cooling transition lies conveniently in the near infrared and the nuclear clock transition can be read out by nuclear/electron shell double resonance

CAOL . International Conference on Advanced Optoelectronics and Lasers•Jul 8, 2004•1 citation

Three-Dimensional Paul Trap with High Secular Frequency for Compact Optical Clock

Ilya A. Semerikov, Ilia V. Zalivako, Alexander S. Borisenko +5 more

The Paul ion trap is developed for the use in a compact frequency standard based on a single ytterbium ion. The design features are the use of atomic ovens for compensating for parasitic electric fields and good optical accessibility. The results on trapping and laser cooling of a single 171 Yb+ ion are presented. A secular frequency of up to 1.2 MHz has been achieved.

Bulletin of the Lebedev Physics Institute•Sep 1, 2019•2 citations
We present the design of a compact optical clock based on the 2 S 1/2 → 2 D 3/2 435.5 nm transition in 171 Yb + . The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred μ m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.
We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.
Outline • Introduction• Why trapped ions for miniaturization?• Miniaturized vacuum package: 1 cm 3 • Pulsed-mode ion clock performance • F-state trapping • Current focus: microwave optical double resonance continuous operation • Alternative ion clock: Alkali Mediated Atomic Clock • Conclusion Miniaturization with Long-Term and Environmental Stability • Achieve Cs Beam Clock performance in a mass and power constrained package • DARPA programs: • IMPACT: improved long-term stability • ACES: improved environmental stability Applications--Excellent timing for: • Rapid GPS acquisition, and GPS denied navigation and timing • Nano/pico (cube) satellites • Pulsed radio and spread spectrum communications Microsemi 5071A Miniature primary frequency standard Approved for Public Release, Distribution Unlimited Critical Elements of the 171 Yb + Clock Trap Electrodes Ions Yb Source Vacuum Package Control and Power Electronics Local Oscillator Magnetic Shield and Coil Repump (935 nm) Optical Pumping/ State Detection Laser (369 nm) Beam Combiner Fluorescence Collection Lens Fluorescence Detector Photo Multiplier Tube (PMT) Ionization UV Light
The 435 mum171Yb+transition is a good candidate for an atomic clock based on an optical transition. We have stored single171Yb ions for several months in RF traps. The ions are cooled, repumped and the clock transition is interrogated by (frequency-doubled) diode lasers. The interrogation laser linewidth was 30 Hz determining the resolvable linewidth of the Yb+transition interrogated. The absolute frequency of this transition was measured using an optical comb generator, self referenced by broadening the spectrum to above one octave, with respect to a Cs fountain clock. Of all systematic frequency shifts to which this transition is subject an estimate indicates that the electric quadruple shift appears is the largest. To obtain a magnitude of the quadruple shift (and the quadruple moment) the clock frequencies of two independently stored and cooled171Yb ions were compared while varying the static electric field in one trap. The measured frequency shift amounting to ~1 Hz/V. This result would seem to permit clocks with much higher accuracy than the clocks based on microwave transition, particularly if the technique of aligning the ions with respect to the electric field were applicable. Anticipating even more precise clocks, we are presently investigating a blue nuclear transition in229Th. Such a nuclear transition should be even better shielded from environmental influences than transitions in the electron shell. This nuclear transition has not yet been directly optically observed. We are presently investigating the luminescence after incoherent broad band optical excitation. The triply ionized223Th is then a suitable system for trapped single ion spectroscopy. The cooling transition lies conveniently in the near infrared and the nuclear clock transition can be read out by nuclear/electron shell double resonance