Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Electronics Letters

Dual‐mode Ramsey microwave cavity for a dual Rb/Cs atomic clock

Guangkun Guo, Jie Liu, Dong Hou, Ke Liu, Houjun Wang, Xianhe Huang, Jie Ma, Fuyu Sun

Published Apr 5, 2018• 10 citations
Publisher

Abstract

As one of the crucial elements of microwave (MW) atomic clocks, Ramsey MW cavities are crucial for assisting MW–atom interactions. A dual‐mode Ramsey cavity for a dual Rb/Cs atomic clock with simultaneous resonances at 6.83 and 9.19 GHz is presented here. The reported cavity, with its high mechanical strength and stability, can excite clock transitions in Rb and Cs atoms in the same zones, thereby providing a compact physical package for a dual Rb/Cs clock. Since both atoms are in the same MW–atom interaction environment, this measurement platform allows for high‐accuracy comparisons.

DOI
10.1049/el.2018.0891

Related papers

Dual-mode Ramsey cavity for a dual Rb/Cs atomic clock

Fuyu Sun, Xianhe Huang, Qingsong Bai

In this paper, we propose a dual-mode Ramsey cavity for a dual Rb/Cs atomic clock, with resonances at 6.83GHz and 9.19GHz under the two different operating modes, respectively. Thus, the proposed cavity can excite Rb atoms and Cs atoms clock transition in the same environment (e.g., static magnetic field, temperature, and/or the asymmetric length between the two arms due to a single U-shaped structure). This design provides a compact physical package for a dual Rb/Cs clock. Another potential application of the dual-mode is high-accuracy comparison measurement. As an example, a dual-mode cavity with TE105 and TE109 modes was simulated.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2016•3 citations

Highly Collimated Collinear Rb/Cs Dual-atom Beam Source

Jie Liu, Xiaofeng Li, Chao Li +4 more

We have designed a highly collimated collinear Rb/Cs atomic beam source device used in vacuum environment, which can be applied to both high-precision comparison measurement based on dual-atom system and dual clock. The developed device allows the separate heating of Rb and Cs atoms, and making the operation mode (Rb mode and/or Cs mode) selectable. During operation, Rb and/or Cs atoms are ejected from the same collimating channel, implying that the travelling paths of the two atomic beams overlap precisely. This is very useful and particularly important for dual-atom system, since the environment of the same temperature field and static magnetic field are achieved while the two atoms interact with microwaves. We will discuss the specific application in dual Rb/Cs beam clocks and demonstrate how the dual beam source works in our dual clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

Double-resonance spectroscopy in Rubidium vapour-cells for high performance and miniature atomic clocks

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +1 more

We report our studies on using microwave-optical double-resonance (DR) spectroscopy for a high-performance Rb vapour-cell atomic clock in view of future industrial applications.The clock physics package is very compact with a total volume of only 0.8 dm 3 .It contains a recently in-house developed magnetron-type cavity and a Rb vapour cell.A homedmade frequency-stabilized laser system with an integrated acousto-optical-modulator (AOM)for switching and controlling the light output power-is used as an optical source in a laser head (LH).The LH has the overall volume of 2.5 dm 3 including the laser diode, optical elements, AOM and electronics.In our Rb atomic clock two schemes of continuous-wave DR and Ramsey-DR schemes are used, where the latter one strongly reduces the light-shift effect by separation of the interaction of light and microwave.Applications of the DR clock approach to more radically miniaturized atomic clocks are discussed.

Journal of Physics Conference Series•Jan 1, 2017•2 citations

A cold-atom Ramsey clock with a low volume physics package

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

arXiv:2305.02944•Scientific Reports•Jan 9, 2024•23 citations

Ramsey-mode Rb cell clock demonstration with a 3D-printed microwave cavity

William Moreno, C. Affolderbach, Matthieu Pellaton +7 more

We demonstrate operation of a Ramey-mode Rb vapor-cell atomic clock based on a microwave cavity realized by additive manufacturing (3D-printing). The cavity design is based on a loop-gap approach and its critical electrode structure is realized in one monolithic piece by stereolithography of a polymer which simplifies the assembly of the cavity. The microwave magnetic field in the cavity shows excellent uniformity and high homogeneity across the Rb cell, which results in high-contrast Ramsey fringes observed on the clock transition. A measured clock stability of 2.2×10-13τ-1/2demonstrates the feasibility of the approach. We discuss aging studies performed on 3D-printed test samples that are of relevance for long-term operation of the clock.

European Frequency and Time Forum•Apr 1, 2018•5 citations

High performance vapour-cell frequency standards

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +4 more

We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between

Journal of Physics Conference Series•Jun 1, 2016•22 citations
As one of the crucial elements of microwave (MW) atomic clocks, Ramsey MW cavities are crucial for assisting MW–atom interactions. A dual‐mode Ramsey cavity for a dual Rb/Cs atomic clock with simultaneous resonances at 6.83 and 9.19 GHz is presented here. The reported cavity, with its high mechanical strength and stability, can excite clock transitions in Rb and Cs atoms in the same zones, thereby providing a compact physical package for a dual Rb/Cs clock. Since both atoms are in the same MW–atom interaction environment, this measurement platform allows for high‐accuracy comparisons.
In this paper, we propose a dual-mode Ramsey cavity for a dual Rb/Cs atomic clock, with resonances at 6.83GHz and 9.19GHz under the two different operating modes, respectively. Thus, the proposed cavity can excite Rb atoms and Cs atoms clock transition in the same environment (e.g., static magnetic field, temperature, and/or the asymmetric length between the two arms due to a single U-shaped structure). This design provides a compact physical package for a dual Rb/Cs clock. Another potential application of the dual-mode is high-accuracy comparison measurement. As an example, a dual-mode cavity with TE105 and TE109 modes was simulated.
We have designed a highly collimated collinear Rb/Cs atomic beam source device used in vacuum environment, which can be applied to both high-precision comparison measurement based on dual-atom system and dual clock. The developed device allows the separate heating of Rb and Cs atoms, and making the operation mode (Rb mode and/or Cs mode) selectable. During operation, Rb and/or Cs atoms are ejected from the same collimating channel, implying that the travelling paths of the two atomic beams overlap precisely. This is very useful and particularly important for dual-atom system, since the environment of the same temperature field and static magnetic field are achieved while the two atoms interact with microwaves. We will discuss the specific application in dual Rb/Cs beam clocks and demonstrate how the dual beam source works in our dual clock.
We report our studies on using microwave-optical double-resonance (DR) spectroscopy for a high-performance Rb vapour-cell atomic clock in view of future industrial applications.The clock physics package is very compact with a total volume of only 0.8 dm 3 .It contains a recently in-house developed magnetron-type cavity and a Rb vapour cell.A homedmade frequency-stabilized laser system with an integrated acousto-optical-modulator (AOM)for switching and controlling the light output power-is used as an optical source in a laser head (LH).The LH has the overall volume of 2.5 dm 3 including the laser diode, optical elements, AOM and electronics.In our Rb atomic clock two schemes of continuous-wave DR and Ramsey-DR schemes are used, where the latter one strongly reduces the light-shift effect by separation of the interaction of light and microwave.Applications of the DR clock approach to more radically miniaturized atomic clocks are discussed.
We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.
We demonstrate operation of a Ramey-mode Rb vapor-cell atomic clock based on a microwave cavity realized by additive manufacturing (3D-printing). The cavity design is based on a loop-gap approach and its critical electrode structure is realized in one monolithic piece by stereolithography of a polymer which simplifies the assembly of the cavity. The microwave magnetic field in the cavity shows excellent uniformity and high homogeneity across the Rb cell, which results in high-contrast Ramsey fringes observed on the clock transition. A measured clock stability of 2.2×10-13τ-1/2demonstrates the feasibility of the approach. We discuss aging studies performed on 3D-printed test samples that are of relevance for long-term operation of the clock.
We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between