Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Dual-mode Ramsey cavity for a dual Rb/Cs atomic clock

Fuyu Sun, Xianhe Huang, Qingsong Bai

Published May 1, 2016• 3 citations
Publisher

Abstract

In this paper, we propose a dual-mode Ramsey cavity for a dual Rb/Cs atomic clock, with resonances at 6.83GHz and 9.19GHz under the two different operating modes, respectively. Thus, the proposed cavity can excite Rb atoms and Cs atoms clock transition in the same environment (e.g., static magnetic field, temperature, and/or the asymmetric length between the two arms due to a single U-shaped structure). This design provides a compact physical package for a dual Rb/Cs clock. Another potential application of the dual-mode is high-accuracy comparison measurement. As an example, a dual-mode cavity with TE105 and TE109 modes was simulated.

DOI
10.1109/fcs.2016.7546815

Related papers

Dual‐mode Ramsey microwave cavity for a dual Rb/Cs atomic clock

Guangkun Guo, Jie Liu, Dong Hou +5 more

As one of the crucial elements of microwave (MW) atomic clocks, Ramsey MW cavities are crucial for assisting MW–atom interactions. A dual‐mode Ramsey cavity for a dual Rb/Cs atomic clock with simultaneous resonances at 6.83 and 9.19 GHz is presented here. The reported cavity, with its high mechanical strength and stability, can excite clock transitions in Rb and Cs atoms in the same zones, thereby providing a compact physical package for a dual Rb/Cs clock. Since both atoms are in the same MW–atom interaction environment, this measurement platform allows for high‐accuracy comparisons.

Electronics Letters•Apr 5, 2018•10 citations

Highly Collimated Collinear Rb/Cs Dual-atom Beam Source

Jie Liu, Xiaofeng Li, Chao Li +4 more

We have designed a highly collimated collinear Rb/Cs atomic beam source device used in vacuum environment, which can be applied to both high-precision comparison measurement based on dual-atom system and dual clock. The developed device allows the separate heating of Rb and Cs atoms, and making the operation mode (Rb mode and/or Cs mode) selectable. During operation, Rb and/or Cs atoms are ejected from the same collimating channel, implying that the travelling paths of the two atomic beams overlap precisely. This is very useful and particularly important for dual-atom system, since the environment of the same temperature field and static magnetic field are achieved while the two atoms interact with microwaves. We will discuss the specific application in dual Rb/Cs beam clocks and demonstrate how the dual beam source works in our dual clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

Ramsey-mode Rb cell clock demonstration with a 3D-printed microwave cavity

William Moreno, C. Affolderbach, Matthieu Pellaton +7 more

We demonstrate operation of a Ramey-mode Rb vapor-cell atomic clock based on a microwave cavity realized by additive manufacturing (3D-printing). The cavity design is based on a loop-gap approach and its critical electrode structure is realized in one monolithic piece by stereolithography of a polymer which simplifies the assembly of the cavity. The microwave magnetic field in the cavity shows excellent uniformity and high homogeneity across the Rb cell, which results in high-contrast Ramsey fringes observed on the clock transition. A measured clock stability of 2.2×10-13τ-1/2demonstrates the feasibility of the approach. We discuss aging studies performed on 3D-printed test samples that are of relevance for long-term operation of the clock.

European Frequency and Time Forum•Apr 1, 2018•5 citations

Preliminary results of the trapped atom clock on a chip

Clément Lacroûte, Friedemann Reinhard, F. Ramírez-Martínez +4 more

We present an atomic clock based on the interrogation of magnetically trapped (87)Rb atoms. Two photons, in the microwave and radiofrequency domain, excite the clock transition. At a magnetic field of 3.23 G the clock transition from |F = 1, m(F) = -1> to |F = 2, m(F) = 1> is 1st-order insensitive to magnetic field variations. Ramsey interrogation times longer than 2 s can be achieved, leading to a projected clock stability in the low 10(-13) at 1 s for a cloud of 10(5) atoms. We use an atom chip to cool and trap the atoms. A coplanar waveguide is integrated to the chip to carry the Ramsey interrogation signal, making the physics package as small as (5 cm)(3). We describe the experimental setup and show preliminary Ramsey fringes of line width 1.25 Hz.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jan 1, 2010•21 citations

High performance vapour-cell frequency standards

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +4 more

We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between

Journal of Physics Conference Series•Jun 1, 2016•22 citations

A study of irregular-shaped Ramsey cavity for cold-atom microwave clocks

Siqi Jing, Fasong Zheng, Wenxia Song +3 more

Abstract To improve the Ramsey fringe contrast for a portable free-falling-typed cold-atom microwave clock based on a TE 013 -mode cylindrical microwave resonator, this paper innovatively designs an irregular-shaped Ramsey cavity based on the combination of TE 011 and TE 013 modes cylindrical microwave resonators. To ensure b 1 𝜏 1 = b 2 𝜏 2 during the two Ramsey microwave pulses, this study constructs a 3D electromagnetic model to analyze the relationship between the matching factor η = b 1 𝜏 1 /b 2 𝜏 2 and the cavity structural parameters. Simulation results demonstrate that the irregular-shaped Ramsey cavity can effectively generate four spatially separable microwave standing wave fields, with two of them differing in height. The cavity is designed to achieve a central Ramsey fringe with a full width at half maximum (FWHM) of about 9 Hz. By iteratively refining the cavity geometry, the optimal parameters for the cavity dimensions were obtained, with a TE 013 mode height of 100.56 mm and a TE 011 mode height of 34.09 mm. This configuration achieves an amplitude-transit time matching factor η of unity ( η = 1).

Journal of Physics Conference Series•Apr 1, 2026•0 citations
In this paper, we propose a dual-mode Ramsey cavity for a dual Rb/Cs atomic clock, with resonances at 6.83GHz and 9.19GHz under the two different operating modes, respectively. Thus, the proposed cavity can excite Rb atoms and Cs atoms clock transition in the same environment (e.g., static magnetic field, temperature, and/or the asymmetric length between the two arms due to a single U-shaped structure). This design provides a compact physical package for a dual Rb/Cs clock. Another potential application of the dual-mode is high-accuracy comparison measurement. As an example, a dual-mode cavity with TE105 and TE109 modes was simulated.
As one of the crucial elements of microwave (MW) atomic clocks, Ramsey MW cavities are crucial for assisting MW–atom interactions. A dual‐mode Ramsey cavity for a dual Rb/Cs atomic clock with simultaneous resonances at 6.83 and 9.19 GHz is presented here. The reported cavity, with its high mechanical strength and stability, can excite clock transitions in Rb and Cs atoms in the same zones, thereby providing a compact physical package for a dual Rb/Cs clock. Since both atoms are in the same MW–atom interaction environment, this measurement platform allows for high‐accuracy comparisons.
We have designed a highly collimated collinear Rb/Cs atomic beam source device used in vacuum environment, which can be applied to both high-precision comparison measurement based on dual-atom system and dual clock. The developed device allows the separate heating of Rb and Cs atoms, and making the operation mode (Rb mode and/or Cs mode) selectable. During operation, Rb and/or Cs atoms are ejected from the same collimating channel, implying that the travelling paths of the two atomic beams overlap precisely. This is very useful and particularly important for dual-atom system, since the environment of the same temperature field and static magnetic field are achieved while the two atoms interact with microwaves. We will discuss the specific application in dual Rb/Cs beam clocks and demonstrate how the dual beam source works in our dual clock.
We demonstrate operation of a Ramey-mode Rb vapor-cell atomic clock based on a microwave cavity realized by additive manufacturing (3D-printing). The cavity design is based on a loop-gap approach and its critical electrode structure is realized in one monolithic piece by stereolithography of a polymer which simplifies the assembly of the cavity. The microwave magnetic field in the cavity shows excellent uniformity and high homogeneity across the Rb cell, which results in high-contrast Ramsey fringes observed on the clock transition. A measured clock stability of 2.2×10-13τ-1/2demonstrates the feasibility of the approach. We discuss aging studies performed on 3D-printed test samples that are of relevance for long-term operation of the clock.
We present an atomic clock based on the interrogation of magnetically trapped (87)Rb atoms. Two photons, in the microwave and radiofrequency domain, excite the clock transition. At a magnetic field of 3.23 G the clock transition from |F = 1, m(F) = -1> to |F = 2, m(F) = 1> is 1st-order insensitive to magnetic field variations. Ramsey interrogation times longer than 2 s can be achieved, leading to a projected clock stability in the low 10(-13) at 1 s for a cloud of 10(5) atoms. We use an atom chip to cool and trap the atoms. A coplanar waveguide is integrated to the chip to carry the Ramsey interrogation signal, making the physics package as small as (5 cm)(3). We describe the experimental setup and show preliminary Ramsey fringes of line width 1.25 Hz.
We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between
Abstract To improve the Ramsey fringe contrast for a portable free-falling-typed cold-atom microwave clock based on a TE 013 -mode cylindrical microwave resonator, this paper innovatively designs an irregular-shaped Ramsey cavity based on the combination of TE 011 and TE 013 modes cylindrical microwave resonators. To ensure b 1 𝜏 1 = b 2 𝜏 2 during the two Ramsey microwave pulses, this study constructs a 3D electromagnetic model to analyze the relationship between the matching factor η = b 1 𝜏 1 /b 2 𝜏 2 and the cavity structural parameters. Simulation results demonstrate that the irregular-shaped Ramsey cavity can effectively generate four spatially separable microwave standing wave fields, with two of them differing in height. The cavity is designed to achieve a central Ramsey fringe with a full width at half maximum (FWHM) of about 9 Hz. By iteratively refining the cavity geometry, the optimal parameters for the cavity dimensions were obtained, with a TE 013 mode height of 100.56 mm and a TE 011 mode height of 34.09 mm. This configuration achieves an amplitude-transit time matching factor η of unity ( η = 1).