Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Reduction of dick effect in a pulsed CPT vapor cell clock by interleaving lock

Xiaolin Sun, Pengfei Cheng, Yani Zuo, Lijun Wang, Jianwei Zhang, Lijun Wang

Published Jul 1, 2017• 0 citations
Publisher

Abstract

The Dick effect is one of the main limits for a passive atomic frequency standard to reach its frequency instability limit due to quantum projection noise. In this paper, we report on the reduction of Dick effect of a Ramsey-CPT vapor cell clock using interleaving lock. Three parameters are investigated in the process of optimizing sensitivity function in details. By optimizing the sensitivity function, the Dick effect induced Allan deviation (DEAD) can be reduced to the level of 10-14.

DOI
10.1109/fcs.2017.8088872

Related papers

Dick effect in a pulsed atomic clock using coherent population trapping

Jean-Marie Danet, M. Lours, Stéphane Guérandel +1 more

The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.

arXiv:1406.6673•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Apr 1, 2014•66 citations

Ramsey-CPT spectroscopy for a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +3 more

We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks

•Jul 7, 2021•0 citations

Symmetric autobalanced Ramsey interrogation for high-performance coherent-population-trapping vapor-cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, M. Petersen +4 more

We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.

Applied Physics Letters•Jun 11, 2018•78 citations

Prospect for development of a pulsed CPT Raman Ramsey clock using atomic vapor

G. S. Pati, Fredrik K. Fatemi, Mark Bashkansky +1 more

The phenomenon of all-optical Ramsey interference using pulsed coherent population trapping (CPT) beams provides a new avenue for developing frequency standards using atomic vapor. In this study, we show that frequency narrowed Ramsey fringes can be produced in rubidium vapor without the effect of power broadening. We observed fringes of width as narrow as 1 kHz using a buffer-gas filled rubidium cell. A compact injection-locked laser (ILL) system was used to generate CPT beams. Studies also show that ac Stark effect on Ramsey fringes can be reduced, and higher frequency stability can be achieved in a clock application. The results are encouraging to propose an architecture for development of a pulsed CPT Ramsey clock. In this paper, we also provide related discussions on clock frequency stability, and our plans for future experiments.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 11, 2010•2 citations

Dick Effect in a Microwave Frequency Standard Based on Laser-Cooled 113 Cd+ Ions

Jianwei Zhang, K. Miao, Lijun Wang

The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion clock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113 Cd + ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion clock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps.

Chinese Physics Letters•Jan 1, 2015•13 citations

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•89 citations
The Dick effect is one of the main limits for a passive atomic frequency standard to reach its frequency instability limit due to quantum projection noise. In this paper, we report on the reduction of Dick effect of a Ramsey-CPT vapor cell clock using interleaving lock. Three parameters are investigated in the process of optimizing sensitivity function in details. By optimizing the sensitivity function, the Dick effect induced Allan deviation (DEAD) can be reduced to the level of 10-14.
The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.
We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks
We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.
The phenomenon of all-optical Ramsey interference using pulsed coherent population trapping (CPT) beams provides a new avenue for developing frequency standards using atomic vapor. In this study, we show that frequency narrowed Ramsey fringes can be produced in rubidium vapor without the effect of power broadening. We observed fringes of width as narrow as 1 kHz using a buffer-gas filled rubidium cell. A compact injection-locked laser (ILL) system was used to generate CPT beams. Studies also show that ac Stark effect on Ramsey fringes can be reduced, and higher frequency stability can be achieved in a clock application. The results are encouraging to propose an architecture for development of a pulsed CPT Ramsey clock. In this paper, we also provide related discussions on clock frequency stability, and our plans for future experiments.
The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion clock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113 Cd + ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion clock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.