Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Ramsey-CPT spectroscopy for a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly, Emeric de Clercq, Moustafa Abdel Hafiz, Rodolphe Boudot

Published Jul 7, 2021• 0 citations
OpenAlex

Abstract

We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks

Related papers

Exploring Ramsey-CPT spectroscopy in a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +2 more

Chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) have attracted significant research and development efforts due to their unrivaled size-power-stability budget [1]. In such clocks, the continuous-wave (CW) interaction of atoms with light yields power broadening and a significant sensitivity of the clock frequency to light-shift effects that contribute to the clock mid-term and long-term stability budget. Numerous approaches have been demonstrated in the literature to reduce light-shift effects in CW-CPT clocks [2-6]. In this study, using an external acousto-optic modulator to produce the interrogation sequence, we investigate the use of Ramsey-CPT spectroscopy in a buffer-gas filled microcell atomic clock. Some results are compared with those obtained in the standard CW regime. In the Ramsey-CPT case, the clock frequency dependence to laser power is reduced by a factor of 60 with a dark time T of 450 µs, at the expense of a 3 times higher operation power. The sensitivity to microwave power variations is reduced by a factor higher than 2. The Ramsey-CPT interrogation improves the clock Allan deviation for time scales in the 100-10 4 s range, at the expense of a degraded short-term stability when the dark time T is increased too much. A clock frequency stability of 3.8 × 10 −12 at 10 4 s is obtained with T = 450 µs, in comparison with the level of 8 × 10 −11 obtained in the standard CW case, in similar experimental conditions and the same cell. These results suggest that Ramsey-based interrogation protocols might be an attractive approach for the development of CSACs with enhanced mid-and long-term stability.

•Mar 22, 2021•0 citations

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•18 citations

Pulsed coherent population trapping spectroscopy in microfabricated Cs–Ne vapor cells

Rodolphe Boudot, Vincent N. Maurice, Christophe Gorecki +1 more

Pulsed coherent population trapping (CPT) spectroscopy is applied in buffer-gas filled Cs–Ne vapor microfabricated cells. The properties of the Ramsey-CPT clock transition central fringe (linewidth, signal amplitude, and contrast) are studied versus several experimental parameters, including the Ramsey sequence and the input laser intensity, and are compared to those obtained in the conventional continuous (CW) interrogation mode. In the pulsed case and for short Ramsey-free evolution times TR, the central fringe linewidth is found to exhibit a small but visible power broadening and is measured to be narrower than the value of 1/(2TR) that is reached for long TR. The microwave hyperfine coherence lifetime T2 in the Cs–Ne microcells is measured to be in the 50–500 μs range. Its dependence to the buffer gas pressure or cell temperature is briefly studied.

Journal of the Optical Society of America B•Apr 4, 2018•13 citations

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•89 citations

Pulsed-CPT Cs-Ne microcell atomic clock with frequency stability below 2 × 10 −12 at 10 5 s

Clément Carlé, Moustafa Abdel Hafiz, Shervin Keshavarzi +3 more

We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.

Optics Express•Feb 10, 2023•31 citations

Operation of a Ramsey-CPT microcell atomic clock with driving current-based power modulation of a VCSEL

C. M. Rivera-Aguilar, Martin Callejo, Andrei Mursa +6 more

We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.

Applied Physics Letters•Mar 11, 2024•10 citations
We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks
Chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) have attracted significant research and development efforts due to their unrivaled size-power-stability budget [1]. In such clocks, the continuous-wave (CW) interaction of atoms with light yields power broadening and a significant sensitivity of the clock frequency to light-shift effects that contribute to the clock mid-term and long-term stability budget. Numerous approaches have been demonstrated in the literature to reduce light-shift effects in CW-CPT clocks [2-6]. In this study, using an external acousto-optic modulator to produce the interrogation sequence, we investigate the use of Ramsey-CPT spectroscopy in a buffer-gas filled microcell atomic clock. Some results are compared with those obtained in the standard CW regime. In the Ramsey-CPT case, the clock frequency dependence to laser power is reduced by a factor of 60 with a dark time T of 450 µs, at the expense of a 3 times higher operation power. The sensitivity to microwave power variations is reduced by a factor higher than 2. The Ramsey-CPT interrogation improves the clock Allan deviation for time scales in the 100-10 4 s range, at the expense of a degraded short-term stability when the dark time T is increased too much. A clock frequency stability of 3.8 × 10 −12 at 10 4 s is obtained with T = 450 µs, in comparison with the level of 8 × 10 −11 obtained in the standard CW case, in similar experimental conditions and the same cell. These results suggest that Ramsey-based interrogation protocols might be an attractive approach for the development of CSACs with enhanced mid-and long-term stability.
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.
Pulsed coherent population trapping (CPT) spectroscopy is applied in buffer-gas filled Cs–Ne vapor microfabricated cells. The properties of the Ramsey-CPT clock transition central fringe (linewidth, signal amplitude, and contrast) are studied versus several experimental parameters, including the Ramsey sequence and the input laser intensity, and are compared to those obtained in the conventional continuous (CW) interrogation mode. In the pulsed case and for short Ramsey-free evolution times TR, the central fringe linewidth is found to exhibit a small but visible power broadening and is measured to be narrower than the value of 1/(2TR) that is reached for long TR. The microwave hyperfine coherence lifetime T2 in the Cs–Ne microcells is measured to be in the 50–500 μs range. Its dependence to the buffer gas pressure or cell temperature is briefly studied.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.
We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.