A remotely interrogated all-optical 87Rb magnetometer

Brian Patton, Oscar O. Versolato, D. C. Hovde, Eric Corsini, James Higbie, Dmitry Budker

Published Aug 20, 2012• 46 citations
arXivHTMLPDF

Abstract

Atomic magnetometry was performed at Earth’s magnetic field over a free-space distance of ten meters. Two laser beams aimed at a distant alkali-vapor cell excited and detected the 87Rb magnetic resonance, allowing the magnetic field within the cell to be interrogated remotely. Operated as a driven oscillator, the magnetometer measured the geomagnetic field with ≲3.5 pT precision in a ∼2 s data acquisition; this precision was likely limited by ambient field fluctuations. The sensor was also operated in self-oscillating mode with a 5.3 pT/Hz noise floor. Further optimization will yield a high-bandwidth, fully remote magnetometer with sub-pT sensitivity.

DOI
10.1063/1.4747206

Related papers

Remotely-sensed atomic magnetometry

Christopher J. Sataline

Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.

•Jan 1, 2013•0 citations

Remote all optical chip-scale magnetometry

Kfir Levi, Avital Giat, Liron Stern

We propose and demonstrate chip-scale based all-optical remote magnetic sensing. Specifically, we remotely interrogate mm-scale micromachined vapor cells and measure the ambient magnetic field with at a standoff distance of ~10 meters and a sensitivity of ~1 pT/√Hz. Simultaneously we are able to measure the distance between the micro-cell and the interrogating system by means of time-of-flight measurements, thus correlating between position and magnetic field. Consequently, we provide a novel toolset to remotely map arbitrary, remote and hard to access magnetic field in an unshielded environment with high sensitivity and spatial resolution.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•1 citation

All-Optical Broadband Atomic Magnetometer Utilizing Raman-Driven Spin Noise Spectroscopy

Sayari Majumder, Saptarishi Chaudhuri

We report the development and performance of an atomic magnetometer (AM) utilizing the Raman-driven spin noise spectroscopy (RDSNS) technique, which measures the intrinsic spin fluctuations of an atomic medium subjected to a coherent two-photon optical drive. The RDSNS signal is noninvasively detected using a far-off resonant weak probe light utilizing a polarimetric detection scheme. This overcomes the limitations of the small dynamic range and low bandwidth of traditional optically pumped magnetometers (OPMs) or AMs operating in the spin exchange relaxation-free (SERF) regime. We experimentally demonstrate, using both paraffin-coated and buffer-gas-filled vapor cell containing neutral rubidium atoms, that the dynamic range of such magnetometers can reach beyond 150 G while maintaining a dc magnetometer resolution of around 30 pT and a magnetic noise sensitivity of around$30~\text {pT}/\sqrt {\text {Hz}}$at a bandwidth of 100 Hz and a magnetic field of about 0.6 mT. Being an all-optical setup, this instrument is largely immune to interference with stray radio frequency fields and has the potential to be miniaturized and field deployable. One of the practical applications would be to measure variations in geomagnetic fields precisely without having to shield the magnetometer.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•7 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Atomic free-spin-precession magnetometer for biomagnetic measurements in Earth-range magnetic fields

Philipp Neufeld, Janine Riedrich‐Möller, Tino Fuchs +1 more

We present an implementation of an atomic magnetometer based on free spin precession of optically pumped Rb 87 atoms. The design features a microfabricated vapor cell with an effective volume of 7.1 mm 3 containing isotopically enriched Rb 87 and nitrogen buffer gas. The magnetometer is designed to operate in the Earth-field range, exhibiting a magnetic noise floor of about 147 fT / Hz at field strengths comparable to Earth's magnetic field, i.e., around 50 μ T . This is in close agreement with the Cramér-Rao lower bound of 118 fT / Hz . The good sensitivity as well as the high dynamic range enables a wide range of applications, including magnetocardiography and geomagnetic measurements.

APS Open Science•Jun 8, 2026•2 citations

A low-power, high-sensitivity micromachined optical magnetometer

Rahul R. Mhaskar, Svenja A. Knappe, John E. Kitching

We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.

Applied Physics Letters•Dec 10, 2012•175 citations
Atomic magnetometry was performed at Earth’s magnetic field over a free-space distance of ten meters. Two laser beams aimed at a distant alkali-vapor cell excited and detected the 87Rb magnetic resonance, allowing the magnetic field within the cell to be interrogated remotely. Operated as a driven oscillator, the magnetometer measured the geomagnetic field with ≲3.5 pT precision in a ∼2 s data acquisition; this precision was likely limited by ambient field fluctuations. The sensor was also operated in self-oscillating mode with a 5.3 pT/Hz noise floor. Further optimization will yield a high-bandwidth, fully remote magnetometer with sub-pT sensitivity.
Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.
We propose and demonstrate chip-scale based all-optical remote magnetic sensing. Specifically, we remotely interrogate mm-scale micromachined vapor cells and measure the ambient magnetic field with at a standoff distance of ~10 meters and a sensitivity of ~1 pT/√Hz. Simultaneously we are able to measure the distance between the micro-cell and the interrogating system by means of time-of-flight measurements, thus correlating between position and magnetic field. Consequently, we provide a novel toolset to remotely map arbitrary, remote and hard to access magnetic field in an unshielded environment with high sensitivity and spatial resolution.
We report the development and performance of an atomic magnetometer (AM) utilizing the Raman-driven spin noise spectroscopy (RDSNS) technique, which measures the intrinsic spin fluctuations of an atomic medium subjected to a coherent two-photon optical drive. The RDSNS signal is noninvasively detected using a far-off resonant weak probe light utilizing a polarimetric detection scheme. This overcomes the limitations of the small dynamic range and low bandwidth of traditional optically pumped magnetometers (OPMs) or AMs operating in the spin exchange relaxation-free (SERF) regime. We experimentally demonstrate, using both paraffin-coated and buffer-gas-filled vapor cell containing neutral rubidium atoms, that the dynamic range of such magnetometers can reach beyond 150 G while maintaining a dc magnetometer resolution of around 30 pT and a magnetic noise sensitivity of around30 pT/Hz30~\text {pT}/\sqrt {\text {Hz}}30 pT/Hz​at a bandwidth of 100 Hz and a magnetic field of about 0.6 mT. Being an all-optical setup, this instrument is largely immune to interference with stray radio frequency fields and has the potential to be miniaturized and field deployable. One of the practical applications would be to measure variations in geomagnetic fields precisely without having to shield the magnetometer.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
We present an implementation of an atomic magnetometer based on free spin precession of optically pumped Rb 87 atoms. The design features a microfabricated vapor cell with an effective volume of 7.1 mm 3 containing isotopically enriched Rb 87 and nitrogen buffer gas. The magnetometer is designed to operate in the Earth-field range, exhibiting a magnetic noise floor of about 147 fT / Hz at field strengths comparable to Earth's magnetic field, i.e., around 50 μ T . This is in close agreement with the Cramér-Rao lower bound of 118 fT / Hz . The good sensitivity as well as the high dynamic range enables a wide range of applications, including magnetocardiography and geomagnetic measurements.
We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.