Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Feasibility of a stationary micro-SQUID

Jorge Berger

Published Aug 21, 2015• 0 citations
OpenAlex

Abstract

The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation and can change the state of the measured sample. A stationary SQUID could be advantageous when back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.

Related papers

Stationary nano-SQUID: theoretical investigation and feasibility analysis

Jorge Berger

The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation. We estimate the effect that this radiation could have on the measured sample. A stationary SQUID could be advantageous if the oscillation contribution to back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows across the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime, i.e. the densities of normal current and of supercurrent become functions of position only, independent of time. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.

Journal of Physics Condensed Matter•May 30, 2017•2 citations

Proposal for a stationary micro-SQUID

Jorge Berger

We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.

•Aug 21, 2015•0 citations

Nonlocal superconducting quantum interference device

Taewan Noh, Andrew Kindseth, Venkat Chandrasekhar

Superconducting quantum interference devices (SQUIDs) that incorporate two superconductor/insulator/superconductor (SIS) Josephson junctions in a closed loop form the core of some of the most sensitive detectors of magnetic and electric fields currently available. SQUIDs in these applications are typically operated with a finite voltage which generates microwave radiation through the ac Josephson effect. This radiation may impact the system being measured. We describe here a SQUID in which the Josephson junctions are formed from strips of normal metal (N) in good electrical contact with the superconductor (S). Such SNS SQUIDs can be operated under a finite voltage bias with performance comparable or potentially better than conventional SIS SQUIDs. However, they also permit a mode of operation that is based on the unusual interplay of quasiparticle currents and supercurrents in the normal metal of the Josephson junction. The method allows measurements of the flux dependence of the critical current of the SNS SQUID without applying a finite voltage bias across the SNS junction, enabling sensitive flux detection without generating microwave radiation.

arXiv:2011.06667•Physical review. B./Physical review. B•Aug 4, 2021•13 citations

An all thin-film resistive DC SQUID-a current-controlled oscillator

G.S. Krivoy, H. Koch

An all thin-film resistive SQUID with two Josephson tunnel junctions has been designed, fabricated and studied. As well as the two junctions, this device consists of a low ohmic (1.9*10 -6 Omega ) resistive part connected by superconducting leads to both junctions in a loop with very low ( approximately 10 -11 H) inductance. A direct current flowing through the resistive part fixes the voltage difference between the two Josephson junctions that are additionally fed by a bias current. The voltage difference is converted into a signal frequency that can be picked up from the SQUID with a conversion factor of ( phi o ) -1 =483.6 MHz mu V -1 , defined only by the electron charge and Planck's constant. An output signal level (peak-to-peak) of about 50 mu V has been obtained. The low frequency range (below 100 kHz) of the output signal frequency has been investigated. The possibilities of considerably extending this frequency range are also discussed.

Superconductor Science and Technology•Oct 1, 1992•14 citations

Measurements of current noise in DC SQUIDS

John M. Martinis, John L. Clarke

The current noise circulating around the loop of a tunnel junction dc SQUID has been measured as a function of applied flux. The flux noise generated by this current was coupled via a superconducting transformer to a second dc SQUID that was used to measure the noise in a null-balancing configuration. The voltage noise across the SQUID was also measured, using a cooled LC-resonant circuit, and the correlation between the voltage and current noises was determined. The measured values of the noises are in good agreement with values obtained from an analog simulator.

IEEE Transactions on Magnetics•May 1, 1983•21 citations

Analysis on the Suitability of Bi-SQUIDs for the Detection of Trapped Flux in Superconducting Circuits

Tessa Hall, Coenrad Johann Fourie

Quantised magnetic flux trapped during cooldown in superconducting integrated circuits, particularly in thin-film ground planes, couples to nearby circuit structures. The coupling from such fluxons is known to degrade circuit operating margins, or to cause outright operational failure. Measurement of the likely location of one or more trapped fluxons during circuit operation, as well as before and after defluxing steps, can help improve defluxing methods and increase circuit operating margins. A bi-SQUID is a device consisting of three Josephson junctions which demonstrates improved linearity in the voltage-flux response over conventional DC SQUIDs. Conventional DC SQUIDs are being considered as a means of implementing trapped flux detection. Due to the improved linearity of bi-SQUIDs, we investigate their suitability for the same purpose. We present simulation results comparing the sensitivity of different bi-SQUID designs and layout structures to trapped flux and compare bi-SQUID results with a conventional DC SQUID.

IEEE Transactions on Applied Superconductivity•Nov 24, 2025•0 citations
The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation and can change the state of the measured sample. A stationary SQUID could be advantageous when back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.
The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation. We estimate the effect that this radiation could have on the measured sample. A stationary SQUID could be advantageous if the oscillation contribution to back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows across the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime, i.e. the densities of normal current and of supercurrent become functions of position only, independent of time. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.
We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.
Superconducting quantum interference devices (SQUIDs) that incorporate two superconductor/insulator/superconductor (SIS) Josephson junctions in a closed loop form the core of some of the most sensitive detectors of magnetic and electric fields currently available. SQUIDs in these applications are typically operated with a finite voltage which generates microwave radiation through the ac Josephson effect. This radiation may impact the system being measured. We describe here a SQUID in which the Josephson junctions are formed from strips of normal metal (N) in good electrical contact with the superconductor (S). Such SNS SQUIDs can be operated under a finite voltage bias with performance comparable or potentially better than conventional SIS SQUIDs. However, they also permit a mode of operation that is based on the unusual interplay of quasiparticle currents and supercurrents in the normal metal of the Josephson junction. The method allows measurements of the flux dependence of the critical current of the SNS SQUID without applying a finite voltage bias across the SNS junction, enabling sensitive flux detection without generating microwave radiation.
An all thin-film resistive SQUID with two Josephson tunnel junctions has been designed, fabricated and studied. As well as the two junctions, this device consists of a low ohmic (1.9*10 -6 Omega ) resistive part connected by superconducting leads to both junctions in a loop with very low ( approximately 10 -11 H) inductance. A direct current flowing through the resistive part fixes the voltage difference between the two Josephson junctions that are additionally fed by a bias current. The voltage difference is converted into a signal frequency that can be picked up from the SQUID with a conversion factor of ( phi o ) -1 =483.6 MHz mu V -1 , defined only by the electron charge and Planck's constant. An output signal level (peak-to-peak) of about 50 mu V has been obtained. The low frequency range (below 100 kHz) of the output signal frequency has been investigated. The possibilities of considerably extending this frequency range are also discussed.
The current noise circulating around the loop of a tunnel junction dc SQUID has been measured as a function of applied flux. The flux noise generated by this current was coupled via a superconducting transformer to a second dc SQUID that was used to measure the noise in a null-balancing configuration. The voltage noise across the SQUID was also measured, using a cooled LC-resonant circuit, and the correlation between the voltage and current noises was determined. The measured values of the noises are in good agreement with values obtained from an analog simulator.
Quantised magnetic flux trapped during cooldown in superconducting integrated circuits, particularly in thin-film ground planes, couples to nearby circuit structures. The coupling from such fluxons is known to degrade circuit operating margins, or to cause outright operational failure. Measurement of the likely location of one or more trapped fluxons during circuit operation, as well as before and after defluxing steps, can help improve defluxing methods and increase circuit operating margins. A bi-SQUID is a device consisting of three Josephson junctions which demonstrates improved linearity in the voltage-flux response over conventional DC SQUIDs. Conventional DC SQUIDs are being considered as a means of implementing trapped flux detection. Due to the improved linearity of bi-SQUIDs, we investigate their suitability for the same purpose. We present simulation results comparing the sensitivity of different bi-SQUID designs and layout structures to trapped flux and compare bi-SQUID results with a conventional DC SQUID.