The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting

Amplification of Optical Pulse Delays using Weak Measurements

Mohammad Mirhosseini, Omar S. Magaña‐Loaiza, Mehul Malik, Robert W. Boyd

Published Jan 1, 2013• 1 citation
Publisher

Abstract

A novel scheme for super-sensitive measurement of optical pulse delays is proposed based on the concept of weak-value amplification. We discuss an experimental implementation of this technique utilizing a Mach-Zehnder interferometer.
DOI
10.1364/cqo.2013.m6.02

Related papers

Measurement of sub-pulse-width temporal delays via spectral interference induced by weak value amplification

Luis José Salazar-Serrano, Davide Janner, Nicolas Brunner +2 more

We present experimental results of a scheme based on the concepts of weak measurements and weak value amplification to measure temporal delays, much smaller than the pulse width, by means of spectral interference

Conference on Lasers and Electro-Optics•Jan 1, 2014•2 citations

30dB Signal Enhancement by Integrated Weak Value Amplification

Yuhan Mei, Meiting Song, Andrew N. Jordan +1 more

We demonstrate a 30dB signal enhancement in the phase response of an on-chip weak value interferometer compared to a standard Mach-Zehnder interferometer paving the way to ultrahigh sensitivity in classical interferometry.

Conference on Lasers and Electro-Optics•Jan 1, 2025•0 citations

Weak value amplification in an optomechanical system with mach-zehnder interferometer

Sergio Carrasco

•Nov 3, 2021•0 citations

Enhanced On-Chip Phase Measurement by Weak Value Amplification

Meiting Song, John Steinmetz, Yi Zhang +4 more

We show, for the first time, phase measurement with weak value amplification on an integrated photonic chip. We demonstrate 9 dB of signal enhancement over a standard on-chip Mach-Zehnder interferometer with equal detected optical power.

Conference on Lasers and Electro-Optics•Jan 1, 2020•1 citation

Measuring Ultrasmall Time Delays of Light by Joint Weak Measurements

Grégory Strübi, Christoph Bruder

We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.

arXiv:1301.5846•Physical Review Letters•Feb 22, 2013•135 citations

Measurement of sub-pulse-width temporal delays via spectral interference induced by weak value amplification

Luis José Salazar-Serrano, Davide Janner, Nicolas Brunner +2 more

We demonstrate experimentally a scheme to measure small temporal delays, much smaller than the pulse width, between optical pulses. Specifically, we observe an interference effect, based on the concepts of quantum weak measurements and weak value amplification, through which a sub-pulse-width temporal delay between two femtosecond pulses induces a measurable shift of the central frequency of the pulse. The amount of frequency shift, and the accompanying losses of the measurement, can be tailored by postselecting different states of polarization. Our scheme requires only spectrum measurements and linear optics elements, hence greatly facilitating its implementation. Thus it appears to be a promising technique for measuring small and rapidly varying temporal delays.

arXiv:1312.4469•Physical Review A•Jan 27, 2014•62 citations
We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.
We demonstrate experimentally a scheme to measure small temporal delays, much smaller than the pulse width, between optical pulses. Specifically, we observe an interference effect, based on the concepts of quantum weak measurements and weak value amplification, through which a sub-pulse-width temporal delay between two femtosecond pulses induces a measurable shift of the central frequency of the pulse. The amount of frequency shift, and the accompanying losses of the measurement, can be tailored by postselecting different states of polarization. Our scheme requires only spectrum measurements and linear optics elements, hence greatly facilitating its implementation. Thus it appears to be a promising technique for measuring small and rapidly varying temporal delays.