Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1312.4469 · Physical Review A

Measurement of sub-pulse-width temporal delays via spectral interference induced by weak value amplification

Luis José Salazar-Serrano, Davide Janner, Nicolas Brunner, Valerio Pruneri, Juan P. Torres

Published Jan 27, 2014• 62 citations
arXivHTMLPDF

Abstract

We demonstrate experimentally a scheme to measure small temporal delays, much smaller than the pulse width, between optical pulses. Specifically, we observe an interference effect, based on the concepts of quantum weak measurements and weak value amplification, through which a sub-pulse-width temporal delay between two femtosecond pulses induces a measurable shift of the central frequency of the pulse. The amount of frequency shift, and the accompanying losses of the measurement, can be tailored by postselecting different states of polarization. Our scheme requires only spectrum measurements and linear optics elements, hence greatly facilitating its implementation. Thus it appears to be a promising technique for measuring small and rapidly varying temporal delays.

DOI
10.1103/physreva.89.012126

Related papers

Measurement of sub-pulse-width temporal delays via spectral interference induced by weak value amplification

Luis José Salazar-Serrano, Davide Janner, Nicolas Brunner +2 more

We present experimental results of a scheme based on the concepts of weak measurements and weak value amplification to measure temporal delays, much smaller than the pulse width, by means of spectral interference

Conference on Lasers and Electro-Optics•Jan 1, 2014•2 citations

Amplification of Optical Pulse Delays using Weak Measurements

Mohammad Mirhosseini, Omar S. Magaña‐Loaiza, Mehul Malik +1 more

A novel scheme for super-sensitive measurement of optical pulse delays is proposed based on the concept of weak-value amplification. We discuss an experimental implementation of this technique utilizing a Mach-Zehnder interferometer.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2013•1 citation

Weakness of weak values: Incompatibility of anomalous pulse-spectrum amplification and optical frequency combs

John C. Howell

We probe the use of optical frequency combs to place lower bounds on anomalous amplification of a weak-value-measured pulse delay, potentially reaching a theoretical temporal resolution of better than ${10}^{\ensuremath{-}34}$ s. Owing to the interferometric behavior of weak values, we show that anomalous weak value amplification of a time delay is not equivalent to a temporal linear phase ramp. We show that the anomalous weak value is a rearrangement of amplitudes that generates an apparent shift that can be measured in direct detection, but does not change the actual frequency offset of a spectral distribution measurable in coherent detection. This implies that high-precision heterodyne beatnote frequency measurements of an optical frequency comb cannot be used in combination with the weak value amplification, at least in its currently conceived form. This unfortunate feature sheds light on the nature of anomalous weak values in shifting the pointer in a conjugate basis.

Physical Review A•Jul 29, 2022•3 citations

Observation of spectral interference for any path difference in an interferometer

Luis José Salazar-Serrano, Alejandra Valencia, Juan P. Torres

We report experimental observation of spectral interference in a Michelson interferometer, regardless of the relationship between the temporal path difference and the spectral width of an input pulse, by using a weak value amplification scheme.

Frontiers in Optics•Jan 1, 2014•1 citation

Observation of spectral interference for any path difference in an interferometer

Luis José Salazar-Serrano, Alejandra Valencia, Juan P. Torres

We report the experimental observation of spectral interference in a Michelson interferometer, regardless of the relationship between the temporal path difference introduced between the arms of the interferometer and the spectral width of the input pulse. This observation is possible by introducing the polarization degree of freedom into a Michelson interferometer using a typical weak value amplification scenario.

arXiv:1404.1482•Optics Letters•Jul 23, 2014•23 citations

Multiple-weak-value quantum measurement for precision estimation of time delay

Yongsheng Wang, Wenshuai Zhang, Shizhen Chen +2 more

In quantum weak measurement, a weak value is a quantity related to a pointer shift of a measuring device which is usually determined by pre- and postselection states. For conventional weak measurement, a single weak-value model has been well addressed in precision metrology of time delay, but it only holds for a narrowband light source. To further improve the measurement accuracy, a broad-spectrum light source is needed. We find that the single weak-value model no longer holds, due to the occurrence of modified preselection states. Here, a multiple weak-value model is established by introducing the modified preselection states in the estimation of time delay. For broad-spectrum light source with 50-nm spectral width, the multiple weak-value scheme enables us to achieve a high resolution of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}\phantom{\rule{0.16em}{0ex}}\mathrm{as}$. Our proposed multiple weak-value amplification may have important applications in various fields involving precise time-delay detection.

Physical Review A•Mar 25, 2022•14 citations
We demonstrate experimentally a scheme to measure small temporal delays, much smaller than the pulse width, between optical pulses. Specifically, we observe an interference effect, based on the concepts of quantum weak measurements and weak value amplification, through which a sub-pulse-width temporal delay between two femtosecond pulses induces a measurable shift of the central frequency of the pulse. The amount of frequency shift, and the accompanying losses of the measurement, can be tailored by postselecting different states of polarization. Our scheme requires only spectrum measurements and linear optics elements, hence greatly facilitating its implementation. Thus it appears to be a promising technique for measuring small and rapidly varying temporal delays.
We probe the use of optical frequency combs to place lower bounds on anomalous amplification of a weak-value-measured pulse delay, potentially reaching a theoretical temporal resolution of better than ${10}^{\ensuremath{-}34}$ s. Owing to the interferometric behavior of weak values, we show that anomalous weak value amplification of a time delay is not equivalent to a temporal linear phase ramp. We show that the anomalous weak value is a rearrangement of amplitudes that generates an apparent shift that can be measured in direct detection, but does not change the actual frequency offset of a spectral distribution measurable in coherent detection. This implies that high-precision heterodyne beatnote frequency measurements of an optical frequency comb cannot be used in combination with the weak value amplification, at least in its currently conceived form. This unfortunate feature sheds light on the nature of anomalous weak values in shifting the pointer in a conjugate basis.
In quantum weak measurement, a weak value is a quantity related to a pointer shift of a measuring device which is usually determined by pre- and postselection states. For conventional weak measurement, a single weak-value model has been well addressed in precision metrology of time delay, but it only holds for a narrowband light source. To further improve the measurement accuracy, a broad-spectrum light source is needed. We find that the single weak-value model no longer holds, due to the occurrence of modified preselection states. Here, a multiple weak-value model is established by introducing the modified preselection states in the estimation of time delay. For broad-spectrum light source with 50-nm spectral width, the multiple weak-value scheme enables us to achieve a high resolution of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}\phantom{\rule{0.16em}{0ex}}\mathrm{as}$. Our proposed multiple weak-value amplification may have important applications in various fields involving precise time-delay detection.