Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Optics

Technical Advantages for Weak-Value Amplification

Julián Martínez-Rincón, Gerardo I. Viza, G. B. Alves, Andrew N. Jordan, John C. Howell

Published Jan 1, 2015• 3 citations
Publisher

Abstract

We consider different types of technical noise in an optical context and show that weak-value amplification techniques (using a small fraction of photons) compare favourably with standard techniques (using all of them). We measure small beam deflections of an optical beam by monitoring the dark port in a Sagnac interferometer (weak-value technique) or by focusing the entire beam onto a split detector (standard technique). In all cases, the weak-value technique performs favourable in precision respect to the standard technique.

DOI
10.1364/fio.2015.jw2a.37

Related papers

Experimentally quantifying the advantages of weak-value-based metrology

Gerardo I. Viza, Julián Martínez-Rincón, G. B. Alves +2 more

We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on $1%$ of the photons, we obtain $99%$ of the available Fisher information of the beam deflection parameter.

arXiv:1410.8461•Physical Review A•Sep 22, 2015•127 citations

Deflection Measurements with Weak Values

P. Ben Dixon, David J. Starling, Nathan S. Williams +3 more

We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.

Frontiers in Optics•Jan 1, 2010•0 citations

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

Sang‐Joon Park, Hyoung Joo Kim, Jaewoo Noh

We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

Journal of the Optical Society of Korea•Sep 25, 2012•2 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Optimizing the signal-to-noise ratio of a beam-deflection measurement with interferometric weak values

David J. Starling, P. Ben Dixon, Andrew N. Jordan +1 more

The amplification obtained using weak values is quantified through a detailed investigation of the signal-to-noise ratio for an optical beam-deflection measurement. We show that for a given deflection, input power and beam radius, the use of interferometric weak values allows one to obtain the optimum signal-to-noise ratio using a coherent beam. This method has the advantage of reduced technical noise and allows for the use of detectors with a low saturation intensity. We report on an experiment which improves the signal-to-noise ratio for a beam-deflection measurement by a factor of 54 when compared to a measurement using the same beam size and a quantum-limited detector.

arXiv:0910.2410•Physical Review A•Oct 8, 2009•215 citations

Experimentally Quantifying the Advantages of Weak-Values-Based Metrology

Gerardo I. Viza, Julián Martínez-Rincón, Gabriel Alves +2 more

We measure optical beam deflections both using a weak-values technique and by focusing. By introducing controlled modulations, the WVT outperforms focusing. Post-selecting on 1\% of the photons, we obtain 99\% of the available Fisher information.

Conference on Lasers and Electro-Optics•Jan 1, 2015•4 citations
We consider different types of technical noise in an optical context and show that weak-value amplification techniques (using a small fraction of photons) compare favourably with standard techniques (using all of them). We measure small beam deflections of an optical beam by monitoring the dark port in a Sagnac interferometer (weak-value technique) or by focusing the entire beam onto a split detector (standard technique). In all cases, the weak-value technique performs favourable in precision respect to the standard technique.
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on 11%1 of the photons, we obtain 9999%99 of the available Fisher information of the beam deflection parameter.
We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
The amplification obtained using weak values is quantified through a detailed investigation of the signal-to-noise ratio for an optical beam-deflection measurement. We show that for a given deflection, input power and beam radius, the use of interferometric weak values allows one to obtain the optimum signal-to-noise ratio using a coherent beam. This method has the advantage of reduced technical noise and allows for the use of detectors with a low saturation intensity. We report on an experiment which improves the signal-to-noise ratio for a beam-deflection measurement by a factor of 54 when compared to a measurement using the same beam size and a quantum-limited detector.