Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0910.2410 · Physical Review A

Optimizing the signal-to-noise ratio of a beam-deflection measurement with interferometric weak values

David J. Starling, P. Ben Dixon, Andrew N. Jordan, John C. Howell

Published Oct 8, 2009• 215 citations
arXivHTMLPDF

Abstract

The amplification obtained using weak values is quantified through a detailed investigation of the signal-to-noise ratio for an optical beam-deflection measurement. We show that for a given deflection, input power and beam radius, the use of interferometric weak values allows one to obtain the optimum signal-to-noise ratio using a coherent beam. This method has the advantage of reduced technical noise and allows for the use of detectors with a low saturation intensity. We report on an experiment which improves the signal-to-noise ratio for a beam-deflection measurement by a factor of 54 when compared to a measurement using the same beam size and a quantum-limited detector.

DOI
10.1103/physreva.80.041803

Related papers

Deflection Measurements with Weak Values

P. Ben Dixon, David J. Starling, Nathan S. Williams +3 more

We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.

Frontiers in Optics•Jan 1, 2010•0 citations

Technical Advantages for Weak-Value Amplification

Julián Martínez-Rincón, Gerardo I. Viza, G. B. Alves +2 more

We consider different types of technical noise in an optical context and show that weak-value amplification techniques (using a small fraction of photons) compare favourably with standard techniques (using all of them). We measure small beam deflections of an optical beam by monitoring the dark port in a Sagnac interferometer (weak-value technique) or by focusing the entire beam onto a split detector (standard technique). In all cases, the weak-value technique performs favourable in precision respect to the standard technique.

Frontiers in Optics•Jan 1, 2015•3 citations

Power-Recycled Weak-Value-Based Metrology

Kevin Lyons, Justin Dressel, Andrew N. Jordan +2 more

We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in all the light exiting to the detector with a large deflection, thus eliminating the inefficiency of the rare postselection. The signal-to-noise ratio of the deflection is itself magnified by the weak value. We discuss ways to realize this proposal, using a transverse beam filter and different cavity designs.

arXiv:1504.08210•Physical Review Letters•Apr 29, 2015•73 citations

Experimentally quantifying the advantages of weak-value-based metrology

Gerardo I. Viza, Julián Martínez-Rincón, G. B. Alves +2 more

We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on $1%$ of the photons, we obtain $99%$ of the available Fisher information of the beam deflection parameter.

arXiv:1410.8461•Physical Review A•Sep 22, 2015•127 citations

Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification

P. Ben Dixon, David J. Starling, Andrew N. Jordan +1 more

We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.

arXiv:0906.4828•Physical Review Letters•Apr 27, 2009•773 citations

Amplifying Single-Photon Nonlinearity Using Weak Measurements

Amir Feizpour, Xingxing Xing, Aephraim M. Steinberg

We show that weak measurement can be used to "amplify" optical nonlinearities at the single-photon level, such that the effect of one properly postselected photon on a classical beam may be as large as that of many unpostselected photons. We find that "weak-value amplification" offers a marked improvement in the signal-to-noise ratio in the presence of technical noise with long correlation times. Unlike previous weak-measurement experiments, our proposed scheme has no classical equivalent.

arXiv:1101.0199•Physical Review Letters•Sep 23, 2011•268 citations
The amplification obtained using weak values is quantified through a detailed investigation of the signal-to-noise ratio for an optical beam-deflection measurement. We show that for a given deflection, input power and beam radius, the use of interferometric weak values allows one to obtain the optimum signal-to-noise ratio using a coherent beam. This method has the advantage of reduced technical noise and allows for the use of detectors with a low saturation intensity. We report on an experiment which improves the signal-to-noise ratio for a beam-deflection measurement by a factor of 54 when compared to a measurement using the same beam size and a quantum-limited detector.
We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.
We consider different types of technical noise in an optical context and show that weak-value amplification techniques (using a small fraction of photons) compare favourably with standard techniques (using all of them). We measure small beam deflections of an optical beam by monitoring the dark port in a Sagnac interferometer (weak-value technique) or by focusing the entire beam onto a split detector (standard technique). In all cases, the weak-value technique performs favourable in precision respect to the standard technique.
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on 11%1 of the photons, we obtain 9999%99 of the available Fisher information of the beam deflection parameter.
We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.
We show that weak measurement can be used to "amplify" optical nonlinearities at the single-photon level, such that the effect of one properly postselected photon on a classical beam may be as large as that of many unpostselected photons. We find that "weak-value amplification" offers a marked improvement in the signal-to-noise ratio in the presence of technical noise with long correlation times. Unlike previous weak-measurement experiments, our proposed scheme has no classical equivalent.