Applied Physics Letters

Flux modulation scheme for direct current SQUID readout revisited

Tao Hong, Hai Wang, Yi Zhang, Hans‐Joachim Krause, Alex I. Braginski, Xiaoming Xie, Andreas Offenhäusser, Mianheng Jiang

Published Feb 8, 2016• 4 citations
Publisher

Abstract

The flux modulation scheme (FMS) is the standard readout technique of dc SQUIDs, where a step-up transformer links the SQUID to the preamplifier. The transformer's primary winding shunts the SQUID via a large capacitor while the secondary winding connects it to the preamplifier. A modulation flux having a frequency of typically 100 kHz generates an ac voltage across the SQUID, stepped up by the transformer. The SQUID with FMS is customarily operated in the current bias mode, because a constant dc bias current flows only through the SQUID due to the capacitor isolation. With FMS, however, the transformer ac shunts the SQUID so that in reality the operating mode is neither purely current-biased nor voltage-biased but rather nominal current-biased or “mixed biased.” Our objective is to experimentally investigate the consequences of ac shunting of the dc SQUID in FMS and the transformer's transfer characteristics. For different shunt values we measure the change in the SQUID bias current due to the ac shunt using another SQUID in the two-stage readout scheme, and simultaneously monitor the SQUID output voltage signal. We then explain our measurements by a simplified graphic analysis of SQUID intrinsic current-voltage (I–V) characteristics. Since the total current flowing through the SQUID is not constant due to the shunting effect of the transformer, the amplitude of SQUID flux-to-voltage characteristics V(Φ) is less as compared to the direct readout scheme (DRS). Furthermore, we analyze and compare V(Φ) obtained by DRS and FMS. We show that in FMS, the transfer characteristics of the SQUID circuit also depend on the isolation capacitance and the dynamic resistance of the SQUID.

DOI
10.1063/1.4941665

Related papers

Flux Modulation Scheme ( FMS )

Yi Zhang, Hui Dong, Hans-Joachim Krause +2 more

This chapter introduces the “mixed bias mode” and discusses the flux modulation scheme (FMS). It revisits the FMS by analyzing the bias mode and the transfer characteristics of a step-up transformer. The readout schemes share the common idea of modifying the Superconducting QUantum Interference Device (SQUID) input circuit to enhance the SQUID's apparent transfer coefficient at the input terminals of the preamplifier. The SQUID is matched to a preamplifier via a four-terminal step-up transformer. The “head stage” of the FMS is essentially an AC circuit and is calibrated by the amplitude- and phase-to-frequency transfer characteristics of the transformer. The two imperfections for SQUID operation in FMS, one is the shunt effect of primary winding and the other is nonlinear transformation from primary winding to secondary winding, to reduce benefit of the transformer.

Wiley eBooks•May 29, 2020•0 citations

Study on Noise Matching Between SQUID Sensor and Its Readout Electronics

Hai Wang, Hua Chen, Xiangyan Kong +3 more

Noise matching between superconducting quantum interference device (SQUID) sensor and readout electronics has always been an important problem. Conventionally, in order to avoid the hysteresis, SQUIDs should be operated in the range of βccis the Stewart-McCumber parameter. Recently, Liu et al. extended the SQUID operating area to βc > 1 due to a large noise parameter Γ*. When βc> 1, SQUID exhibits a large ∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout electronics, δΦe. In this work, we compare the SQUID system noise δΦsmeasured with four different readout electronics. Here, the four readout electronics employed are as follows: 1) the flux modulation scheme (FMS); 2) the direct readout scheme (DRS), which uses six parallel connected bipolar transistor as its preamplifier (DRS-PCBT); 3) the DRS, which uses a single preamplifier AD797 (DRS-AD797); and 4) the two-stage scheme. The preamplifier voltage noise of DRS-PCBT and DRS-AD797 are about 0.4 nV/√Hz and 0.9 nV/√Hz, respectively. For a two-stage scheme, the equivalent flux noise reaches about 0.25 μΦ0/√Hz, the measured SQUID intrinsic noise, δΦi, will dominate δΦs. In other readout schemes, however, δΦsdepends on the value of βc. Finally, we found that FMS is suitable to match SQUIDs with βccc> 3.

IEEE Transactions on Applied Superconductivity•Nov 30, 2016•4 citations

Low-noise ultra-high-speed dc SQUID readout electronics

D. Drung, Colmar Hinnrichs, H.-J. Barthelmess

User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.

Superconductor Science and Technology•Feb 27, 2006•76 citations

Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer

Daniel Richter, Ludwig Hoibl, Thomas Wolber +6 more

We present a MHz frequency-division direct-current superconducting quantum interference device (dc-SQUID) multiplexer that is based on flux ramp modulation and a series array of N identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through additional modulation coils being tightly but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the sum of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as custom readout electronics, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.

arXiv:2101.06424•Applied Physics Letters•Mar 22, 2021•9 citations

dc SQUID's I–V Characteristics and Its Bias Modes

Yi Zhang, Hui Dong, Hans-Joachim Krause +2 more

The physics of a DC Superconducting QUantum Interference Device (SQUID) involves two phenomena: flux quantization and Josephson tunneling. This chapter describes how to measure and understand a SQUID's I–V characteristics. It also describes how to realize an ideal current source for biasing a SQUID and how to set up a practical voltage source to operate a SQUID in voltage bias mode. To study a DC SQUID's features, the first step is to obtain its I–V characteristics. In contrast to the I–V characteristics of the resistor or the diode, those of the SQUID are modulated by the applied flux but are limited within two flux states of integer and half-integer. An ideal current source is characterized by an internal resistance approaching infinity, compared to the SQUID's dynamic resistance. There are only two realized concepts for the SQUID operation in voltage bias mode.

Wiley eBooks•May 29, 2020•0 citations

Dc-SQUID Readout with High Dynamic Range and Intrinsic MHz Frequency-Division Multiplexing Capability

Daniel Richter, A. Fleischmann, C. Enss +1 more

We present a novel dc-SQUID readout scheme that provides linearization of the relation between the input and output signal without using a conventional flux-locked loop circuit. It relies on applying a periodic, sawtooth-shaped magnetic flux signal to the modulation coil of the SQUID to continuously measure the flux-to-voltage SQUID characteristic within each period of the flux ramp. In case that the amplitude and repetition rate of the ramp are chosen such that multiple flux quanta are induced in the SQUID and that the input signal is quasistatic within one period of the flux ramp, the input signal adds a constant magnetic flux offset to the SQUID that leads to a phase shift of the SQUID characteristic being proportional to the input signal. We show that this scheme allows for significantly increasing the dynamic range and that it intrinsically allows for MHz frequency-division SQUID multiplexing.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2019•1 citation
The flux modulation scheme (FMS) is the standard readout technique of dc SQUIDs, where a step-up transformer links the SQUID to the preamplifier. The transformer's primary winding shunts the SQUID via a large capacitor while the secondary winding connects it to the preamplifier. A modulation flux having a frequency of typically 100 kHz generates an ac voltage across the SQUID, stepped up by the transformer. The SQUID with FMS is customarily operated in the current bias mode, because a constant dc bias current flows only through the SQUID due to the capacitor isolation. With FMS, however, the transformer ac shunts the SQUID so that in reality the operating mode is neither purely current-biased nor voltage-biased but rather nominal current-biased or “mixed biased.” Our objective is to experimentally investigate the consequences of ac shunting of the dc SQUID in FMS and the transformer's transfer characteristics. For different shunt values we measure the change in the SQUID bias current due to the ac shunt using another SQUID in the two-stage readout scheme, and simultaneously monitor the SQUID output voltage signal. We then explain our measurements by a simplified graphic analysis of SQUID intrinsic current-voltage (I–V) characteristics. Since the total current flowing through the SQUID is not constant due to the shunting effect of the transformer, the amplitude of SQUID flux-to-voltage characteristics V(Φ) is less as compared to the direct readout scheme (DRS). Furthermore, we analyze and compare V(Φ) obtained by DRS and FMS. We show that in FMS, the transfer characteristics of the SQUID circuit also depend on the isolation capacitance and the dynamic resistance of the SQUID.
This chapter introduces the “mixed bias mode” and discusses the flux modulation scheme (FMS). It revisits the FMS by analyzing the bias mode and the transfer characteristics of a step-up transformer. The readout schemes share the common idea of modifying the Superconducting QUantum Interference Device (SQUID) input circuit to enhance the SQUID's apparent transfer coefficient at the input terminals of the preamplifier. The SQUID is matched to a preamplifier via a four-terminal step-up transformer. The “head stage” of the FMS is essentially an AC circuit and is calibrated by the amplitude- and phase-to-frequency transfer characteristics of the transformer. The two imperfections for SQUID operation in FMS, one is the shunt effect of primary winding and the other is nonlinear transformation from primary winding to secondary winding, to reduce benefit of the transformer.
Noise matching between superconducting quantum interference device (SQUID) sensor and readout electronics has always been an important problem. Conventionally, in order to avoid the hysteresis, SQUIDs should be operated in the range of βccis the Stewart-McCumber parameter. Recently, Liu et al. extended the SQUID operating area to βc > 1 due to a large noise parameter Γ*. When βc> 1, SQUID exhibits a large ∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout electronics, δΦe. In this work, we compare the SQUID system noise δΦsmeasured with four different readout electronics. Here, the four readout electronics employed are as follows: 1) the flux modulation scheme (FMS); 2) the direct readout scheme (DRS), which uses six parallel connected bipolar transistor as its preamplifier (DRS-PCBT); 3) the DRS, which uses a single preamplifier AD797 (DRS-AD797); and 4) the two-stage scheme. The preamplifier voltage noise of DRS-PCBT and DRS-AD797 are about 0.4 nV/√Hz and 0.9 nV/√Hz, respectively. For a two-stage scheme, the equivalent flux noise reaches about 0.25 μΦ0/√Hz, the measured SQUID intrinsic noise, δΦi, will dominate δΦs. In other readout schemes, however, δΦsdepends on the value of βc. Finally, we found that FMS is suitable to match SQUIDs with βccc> 3.
User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.
We present a MHz frequency-division direct-current superconducting quantum interference device (dc-SQUID) multiplexer that is based on flux ramp modulation and a series array of N identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through additional modulation coils being tightly but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the sum of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as custom readout electronics, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.
The physics of a DC Superconducting QUantum Interference Device (SQUID) involves two phenomena: flux quantization and Josephson tunneling. This chapter describes how to measure and understand a SQUID's I–V characteristics. It also describes how to realize an ideal current source for biasing a SQUID and how to set up a practical voltage source to operate a SQUID in voltage bias mode. To study a DC SQUID's features, the first step is to obtain its I–V characteristics. In contrast to the I–V characteristics of the resistor or the diode, those of the SQUID are modulated by the applied flux but are limited within two flux states of integer and half-integer. An ideal current source is characterized by an internal resistance approaching infinity, compared to the SQUID's dynamic resistance. There are only two realized concepts for the SQUID operation in voltage bias mode.
We present a novel dc-SQUID readout scheme that provides linearization of the relation between the input and output signal without using a conventional flux-locked loop circuit. It relies on applying a periodic, sawtooth-shaped magnetic flux signal to the modulation coil of the SQUID to continuously measure the flux-to-voltage SQUID characteristic within each period of the flux ramp. In case that the amplitude and repetition rate of the ramp are chosen such that multiple flux quanta are induced in the SQUID and that the input signal is quasistatic within one period of the flux ramp, the input signal adds a constant magnetic flux offset to the SQUID that leads to a phase shift of the SQUID characteristic being proportional to the input signal. We show that this scheme allows for significantly increasing the dynamic range and that it intrinsically allows for MHz frequency-division SQUID multiplexing.