Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Study on Noise Matching Between SQUID Sensor and Its Readout Electronics

Hai Wang, Hua Chen, Xiangyan Kong, Meiling Wang, Yi Zhang, Xiaoming Xie

Published Nov 30, 2016• 4 citations
Publisher

Abstract

Noise matching between superconducting quantum interference device (SQUID) sensor and readout electronics has always been an important problem. Conventionally, in order to avoid the hysteresis, SQUIDs should be operated in the range of βccis the Stewart-McCumber parameter. Recently, Liu et al. extended the SQUID operating area to βc > 1 due to a large noise parameter Γ*. When βc> 1, SQUID exhibits a large ∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout electronics, δΦe. In this work, we compare the SQUID system noise δΦsmeasured with four different readout electronics. Here, the four readout electronics employed are as follows: 1) the flux modulation scheme (FMS); 2) the direct readout scheme (DRS), which uses six parallel connected bipolar transistor as its preamplifier (DRS-PCBT); 3) the DRS, which uses a single preamplifier AD797 (DRS-AD797); and 4) the two-stage scheme. The preamplifier voltage noise of DRS-PCBT and DRS-AD797 are about 0.4 nV/√Hz and 0.9 nV/√Hz, respectively. For a two-stage scheme, the equivalent flux noise reaches about 0.25 μΦ0/√Hz, the measured SQUID intrinsic noise, δΦi, will dominate δΦs. In other readout schemes, however, δΦsdepends on the value of βc. Finally, we found that FMS is suitable to match SQUIDs with βccc> 3.

DOI
10.1109/tasc.2016.2631430

Related papers

Dependence of SQUID Intrinsic Flux Noise on Stewart–McCumber Parameter $\beta_{c}$ of Josephson Junction

Hai Wang, Yongliang Wang, Xiangyan Kong +3 more

It is known that three superconducting quantum interference device (SQUID) parameters, namely, the intrinsic flux noise δΦs, the flux-to-voltage transfer coefficient ∂V/∂Φ, and the dynamic resistance Rd, increase with increasing the Stewart- McCumber parameter βcof Josephson junction. It is very difficult to obtain the low values of δΦsfor a strongly damped SQUID due to its small ∂V/∂Φ. In this paper, we employ a two-stage scheme (TSS) to measure δΦsdirectly. Here, we use single chip readout electronics and a weakly damped SQUID with a βcof flux noise of the readout-SQUID system is about 4.8 μΦ0/√Hz 1.2, both acting as a readout-SQUID system (a preamplifier). The with a corner frequency of about 10 Hz. The front-end SQUID is coupled to the readout SQUID via the input coil with a mutual inductance of Mi. In our experiment, the flux gain for a readout SQUID, i.e., GΦ= Mi× (∂I/∂Φ)front-endis adjusted to be 20. Using the TSS, we measured δΦswith different βcchanging from 0.3 to 13.5 and found δΦsincreasing from 1.0 to 5.0 μΦ0/√Hz. We also discussed the relations between Ls, βc, and δΦsquantitatively. Finally, we proposed designing a suitable βcto match the preamplifier in a direct readout scheme to simplify a SQUID measurement system.

IEEE Transactions on Applied Superconductivity•May 12, 2016•4 citations

Investigation and optimization of low-frequency noise performance in readout electronics of dc superconducting quantum interference device

Jing Bo Zhao, Yi Zhang, Yong-Ho Lee +1 more

We investigated and optimized the low-frequency noise characteristics of a preamplifier used for readout of direct current superconducting quantum interference devices (SQUIDs). When the SQUID output was detected directly using a room-temperature low-voltage-noise preamplifier, the low-frequency noise of a SQUID system was found to be dominated by the input current noise of the preamplifiers in case of a large dynamic resistance of the SQUID. To reduce the current noise of the preamplifier in the low-frequency range, we investigated the dependence of total preamplifier noise on the collector current and source resistance. When the collector current was decreased from 8.4 mA to 3 mA in the preamplifier made of 3 parallel SSM2220 transistor pairs, the low-frequency total voltage noise of the preamplifier (at 0.1 Hz) decreased by about 3 times for a source resistance of 30 Ω whereas the white noise level remained nearly unchanged. Since the relative contribution of preamplifier's input voltage and current noise is different depending on the dynamic resistance or flux-to-voltage transfer of the SQUID, the results showed that the total noise of a SQUID system at low-frequency range can be improved significantly by optimizing the preamplifier circuit parameters, mainly the collector current in case of low-noise bipolar transistor pairs.

Review of Scientific Instruments•May 1, 2014•19 citations

Low-noise ultra-high-speed dc SQUID readout electronics

D. Drung, Colmar Hinnrichs, H.-J. Barthelmess

User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.

Superconductor Science and Technology•Feb 27, 2006•76 citations

Low-noise SQUIDs with large transfer - two stage SQUIDs based on DROSs

M. Podt, Jakob Flokstra, Horst Rogalla

We have realized a two-stage integrated superconducting quantum interference device (SQUID) system with a closed loop bandwidth of 2.5 MHz, operated in a direct voltage readout mode. The corresponding flux slew rate was 1.3×105 Φ0/s and the measured white flux noise was 1.3 μΦ0/√Hz at 4.2 K. The system is based on a conventional dc SQUID with a double relaxation oscillation SQUID (DROS) as the second stage. Because of the large flux-to-voltage transfer, the sensitivity of the system is completely determined by the sensor SQUID and not by the DROS or the room-temperature preamplifier. Decreasing the Josephson junction area enables a further improvement of the sensitivity of the two-stage SQUID systems.

•Aug 26, 2001•0 citations

Two-stage amplifier based on a double relaxation oscillation superconducting quantum interference device

M. Podt, Michiel J. van Duuren, A.W. Hamster +2 more

A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.

Applied Physics Letters•Oct 11, 1999•25 citations

An approach to optimization of the superconducting quantum interference device bootstrap circuit

Guofeng Zhang, Yi Zhang, Hui Dong +5 more

Recently, we demonstrated and analysed the superconducting quantum interference device (SQUID) bootstrap circuit (SBC). It is a direct readout scheme for dc SQUID in the voltage bias mode, permitting one to suppress the preamplifier noise. The SBC enables us to control the two key parameters of a voltage-biased SQUID: the flux-to-current transfer coefficient and the dynamic resistance. The flux-to-current, I-Phi, characteristics of SBC are made asymmetric by introducing the additional current feedback. Depending upon the choice of the working point, this feedback can be positive (working point W-2 on the steeper I-Phi slope) or negative (W-1 on the less steep slope). The dynamic resistance is controlled by the additional voltage feedback. In our publications to date we presented only the SBC operation at W-2, while in this paper we demonstrate operation at W-1 and show that also in this regime the preamplifier noise suppression is possible. We used a liquid-helium-cooled Nb SQUID with a loop inductance of 350 pH and attained white flux noise of 2.5 mu Phi(0) Hz(-1/2) both at W-2 and at W-1. In the latter case, the linear flux range exceeded one half-flux quantum Phi(0). This large linear range should lead to a significantly improved stability and slew rate of the system and also make the tolerable spread in circuit parameters much wider than in all SQUID direct readout schemes known to date. Consequently, operation in this regime opens a new path to possible SBC optimization.

Superconductor Science and Technology•Apr 21, 2011•11 citations
Noise matching between superconducting quantum interference device (SQUID) sensor and readout electronics has always been an important problem. Conventionally, in order to avoid the hysteresis, SQUIDs should be operated in the range of βccis the Stewart-McCumber parameter. Recently, Liu et al. extended the SQUID operating area to βc > 1 due to a large noise parameter Γ*. When βc> 1, SQUID exhibits a large ∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout electronics, δΦe. In this work, we compare the SQUID system noise δΦsmeasured with four different readout electronics. Here, the four readout electronics employed are as follows: 1) the flux modulation scheme (FMS); 2) the direct readout scheme (DRS), which uses six parallel connected bipolar transistor as its preamplifier (DRS-PCBT); 3) the DRS, which uses a single preamplifier AD797 (DRS-AD797); and 4) the two-stage scheme. The preamplifier voltage noise of DRS-PCBT and DRS-AD797 are about 0.4 nV/√Hz and 0.9 nV/√Hz, respectively. For a two-stage scheme, the equivalent flux noise reaches about 0.25 μΦ0/√Hz, the measured SQUID intrinsic noise, δΦi, will dominate δΦs. In other readout schemes, however, δΦsdepends on the value of βc. Finally, we found that FMS is suitable to match SQUIDs with βccc> 3.
Dependence of SQUID Intrinsic Flux Noise on Stewart–McCumber Parameter βc\beta_{c}βc​ of Josephson Junction
It is known that three superconducting quantum interference device (SQUID) parameters, namely, the intrinsic flux noise δΦs, the flux-to-voltage transfer coefficient ∂V/∂Φ, and the dynamic resistance Rd, increase with increasing the Stewart- McCumber parameter βcof Josephson junction. It is very difficult to obtain the low values of δΦsfor a strongly damped SQUID due to its small ∂V/∂Φ. In this paper, we employ a two-stage scheme (TSS) to measure δΦsdirectly. Here, we use single chip readout electronics and a weakly damped SQUID with a βcof flux noise of the readout-SQUID system is about 4.8 μΦ0/√Hz 1.2, both acting as a readout-SQUID system (a preamplifier). The with a corner frequency of about 10 Hz. The front-end SQUID is coupled to the readout SQUID via the input coil with a mutual inductance of Mi. In our experiment, the flux gain for a readout SQUID, i.e., GΦ= Mi× (∂I/∂Φ)front-endis adjusted to be 20. Using the TSS, we measured δΦswith different βcchanging from 0.3 to 13.5 and found δΦsincreasing from 1.0 to 5.0 μΦ0/√Hz. We also discussed the relations between Ls, βc, and δΦsquantitatively. Finally, we proposed designing a suitable βcto match the preamplifier in a direct readout scheme to simplify a SQUID measurement system.
We investigated and optimized the low-frequency noise characteristics of a preamplifier used for readout of direct current superconducting quantum interference devices (SQUIDs). When the SQUID output was detected directly using a room-temperature low-voltage-noise preamplifier, the low-frequency noise of a SQUID system was found to be dominated by the input current noise of the preamplifiers in case of a large dynamic resistance of the SQUID. To reduce the current noise of the preamplifier in the low-frequency range, we investigated the dependence of total preamplifier noise on the collector current and source resistance. When the collector current was decreased from 8.4 mA to 3 mA in the preamplifier made of 3 parallel SSM2220 transistor pairs, the low-frequency total voltage noise of the preamplifier (at 0.1 Hz) decreased by about 3 times for a source resistance of 30 Ω whereas the white noise level remained nearly unchanged. Since the relative contribution of preamplifier's input voltage and current noise is different depending on the dynamic resistance or flux-to-voltage transfer of the SQUID, the results showed that the total noise of a SQUID system at low-frequency range can be improved significantly by optimizing the preamplifier circuit parameters, mainly the collector current in case of low-noise bipolar transistor pairs.
User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.
We have realized a two-stage integrated superconducting quantum interference device (SQUID) system with a closed loop bandwidth of 2.5 MHz, operated in a direct voltage readout mode. The corresponding flux slew rate was 1.3×105 Φ0/s and the measured white flux noise was 1.3 μΦ0/√Hz at 4.2 K. The system is based on a conventional dc SQUID with a double relaxation oscillation SQUID (DROS) as the second stage. Because of the large flux-to-voltage transfer, the sensitivity of the system is completely determined by the sensor SQUID and not by the DROS or the room-temperature preamplifier. Decreasing the Josephson junction area enables a further improvement of the sensitivity of the two-stage SQUID systems.
A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.
Recently, we demonstrated and analysed the superconducting quantum interference device (SQUID) bootstrap circuit (SBC). It is a direct readout scheme for dc SQUID in the voltage bias mode, permitting one to suppress the preamplifier noise. The SBC enables us to control the two key parameters of a voltage-biased SQUID: the flux-to-current transfer coefficient and the dynamic resistance. The flux-to-current, I-Phi, characteristics of SBC are made asymmetric by introducing the additional current feedback. Depending upon the choice of the working point, this feedback can be positive (working point W-2 on the steeper I-Phi slope) or negative (W-1 on the less steep slope). The dynamic resistance is controlled by the additional voltage feedback. In our publications to date we presented only the SBC operation at W-2, while in this paper we demonstrate operation at W-1 and show that also in this regime the preamplifier noise suppression is possible. We used a liquid-helium-cooled Nb SQUID with a loop inductance of 350 pH and attained white flux noise of 2.5 mu Phi(0) Hz(-1/2) both at W-2 and at W-1. In the latter case, the linear flux range exceeded one half-flux quantum Phi(0). This large linear range should lead to a significantly improved stability and slew rate of the system and also make the tolerable spread in circuit parameters much wider than in all SQUID direct readout schemes known to date. Consequently, operation in this regime opens a new path to possible SBC optimization.