Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

Progress towards a strontium optical lattice clock at NTSC

Wang Ye-Bing, Liu Hui, 卢本全 LU Ben-quan, Ren Jie, Qinfang Xu, Yin Mo-Juan, Kong De-Huan, Ma Jie, Hong Chang

Published Aug 1, 2015• 0 citations
Publisher

Abstract

Stable narrow line lasers are built up and some precision measurements are performed. Based on the cold88Sr atoms loaded in to one dimension optical lattice, a sideband resolved clock transition spectrum is obtained.
DOI
10.1109/cleopr.2015.7376017

Related papers

Optical lattice clock with ultracold strontium atoms

Martin M. Boyd, Andrew D. Ludlow, Tanya Zelevinsky +4 more

We report recent progress on an optical atomic clock based on the ultranarrow 1S 0 -3P 0 transition in fermionic neutral strontium atoms confined in an optical lattice. A detailed systematic study of the clock transition frequency is presented along with the recent improvement in the measured line quality factor which is expected to lead to an accuracy of 10−15 or better in the near future.

European Frequency and Time Forum•Mar 27, 2006•0 citations

Progress towards a strontium optical lattice clock at NPL

Elizabeth M. Bridge, Ian R. Hill, Yuri B. Ovchinnikov +3 more

The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].

European Frequency and Time Forum•Apr 1, 2010•0 citations

Systematic Study of the Sr87 Clock Transition in an Optical Lattice

Andrew D. Ludlow, Martin M. Boyd, Tanya Zelevinsky +5 more

With ultracold 87Srconfined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to date of the 1S0-3P0 optical clock transition with a detailed analysis of systematic shifts (19 Hz uncertainty) in the absolute frequency measurement of 429 228 004 229 869 Hz. The high resolution permits an investigation of the optical lattice motional sideband structure. The local oscillator for this optical atomic clock is a stable diode laser with its hertz-level linewidth characterized by an octave-spanning femtosecond frequency comb.

arXiv:physics/0508041•Physical Review Letters•Jan 26, 2006•197 citations

High Precision Spectroscopy of Strontium in an Optical Lattice: Towards a New Standard for Frequency and Time

Martin M. Boyd

Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise

•Jan 1, 2007•39 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•9 citations

The development towards the optical lattice clock of strontium atom in National Time Service Center

Xin Na Tian, Y. B. Wang, H. Liu +6 more

At present the optical clock with accuracy and stability achieves to 10-18 level, which could be the next generation of time and frequency standard. This paper gives an introduction of the progress of researching on the optical lattice clock of Strontium atom in NTSC (National Time Service Center). We realize the (5s5s)1S0—(5s5p)1P1 cooling (blue MOT) and (5s5s)1S0—(5s5p)3P1 cooling (red MOT) in succession for the optical lattice clock, and loading these cold atoms in a lattice composed by a magic wave-length is studied. By using our narrow line-width diode laser and the fiber femtosecond optical frequency comb, we precisely measure the absolute frequencies of the inter-combination transitions (5s5s)1S0—(5s5p)3P1 of four isotopes of Strontium referenced to an H maser.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 21, 2014•0 citations
The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].
With ultracold 87Srconfined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to date of the 1S0-3P0 optical clock transition with a detailed analysis of systematic shifts (19 Hz uncertainty) in the absolute frequency measurement of 429 228 004 229 869 Hz. The high resolution permits an investigation of the optical lattice motional sideband structure. The local oscillator for this optical atomic clock is a stable diode laser with its hertz-level linewidth characterized by an octave-spanning femtosecond frequency comb.
Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.
At present the optical clock with accuracy and stability achieves to 10-18 level, which could be the next generation of time and frequency standard. This paper gives an introduction of the progress of researching on the optical lattice clock of Strontium atom in NTSC (National Time Service Center). We realize the (5s5s)1S0—(5s5p)1P1 cooling (blue MOT) and (5s5s)1S0—(5s5p)3P1 cooling (red MOT) in succession for the optical lattice clock, and loading these cold atoms in a lattice composed by a magic wave-length is studied. By using our narrow line-width diode laser and the fiber femtosecond optical frequency comb, we precisely measure the absolute frequencies of the inter-combination transitions (5s5s)1S0—(5s5p)3P1 of four isotopes of Strontium referenced to an H maser.