Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

The development towards the optical lattice clock of strontium atom in National Time Service Center

Xin Na Tian, Y. B. Wang, H. Liu, F. Gao, J. Ren, B. Q. Lu, Q. F. Xu, Yi Xie, Hong Chang

Published Aug 21, 2014• 0 citations
Publisher

Abstract

At present the optical clock with accuracy and stability achieves to 10-18 level, which could be the next generation of time and frequency standard. This paper gives an introduction of the progress of researching on the optical lattice clock of Strontium atom in NTSC (National Time Service Center). We realize the (5s5s)1S0—(5s5p)1P1 cooling (blue MOT) and (5s5s)1S0—(5s5p)3P1 cooling (red MOT) in succession for the optical lattice clock, and loading these cold atoms in a lattice composed by a magic wave-length is studied. By using our narrow line-width diode laser and the fiber femtosecond optical frequency comb, we precisely measure the absolute frequencies of the inter-combination transitions (5s5s)1S0—(5s5p)3P1 of four isotopes of Strontium referenced to an H maser.

DOI
10.1117/12.2068993

Related papers

Recent Advances Concerning the 87Sr Optical Lattice Clock at the National Time Service Center

Yebing Wang, Xiaotong Lu, Benquan Lu +2 more

We review recent experimental progress concerning the 87Sr optical lattice clock at the National Time Service Center in China. Hertz-level spectroscopy of the 87Sr clock transition for the optical lattice clock was performed, and closed-loop operation of the optical lattice clock was realized. A fractional frequency instability of 2.8 × 10−17 was attained for an averaging time of 2000 s. The Allan deviation is found to be 1.6 × 10−15/τ1/2 and is limited mainly by white-frequency-noise. The Landé g-factors of the (5s2)1S0 and (5s5p)3P0 states in 87Sr were measured experimentally; they are important for evaluating the clock’s Zeeman shifts. We also present recent work on the miniaturization of the strontium optical lattice clock for space applications.

Applied Sciences•Nov 8, 2018•14 citations

Experimental research on loading strontium bosons into the optical lattice operating at the “magic” wavelength

Tian Xiao, Wang Ye-Bing, Lu Ben-Quan +7 more

The optical lattice clock with neutral atoms occupies an outstanding position in the research field of atomic clocks, demonstrating the great potential of its performance (like the uncertainty and the stability). At present, the optical lattice clock has realized a 10-18 level of its uncertainty. In this paper, we present the realization of loading bosonic atoms 88Sr (strontium, alkaline-earth metals) into a one-dimensional (1D) optical lattice in our laboratory. The optical lattice where the atoms are trapped can make the energy level shift, called Stark shift. But there is the special optical lattice operating at the “magic” wavelength for clock transitions (5s2) 1S0-(5s5p) 3P0, which can make the same Stark light-shift for both of them, indicating a zero light-shift relative to the clock. In our experiment, Sr atoms are cooled in a two-stage cooling and its temperature can be as low as 2 μK. Then these cold atoms are confined in the Lamb-Dicke region by the lattice laser output from an amplified diode laser operating at the “magic” wavelength, 813 nm. Experimentally, it is straightforward to provide 850 mW of lattice power focused to a 38 μm beam radius. After the cold atoms have trapped in the optical lattice, the lifetime of atoms in 1D optical lattice is measured to be 270 ms. The temperature and the number are about 3.5 μK and 1.2×105 respectively. Besides, effects of the power of the lattice laser on both the number and temperature are analyzed. The number changes linearly with the laser power, while there is no obvious influence on the temperature by the power. This original and special approach for atoms trapped in the optical lattice can provide a long interrogation time for probing the clock transition. Furthermore, it may be the foundation for developing our optical lattice clock of strontium atoms.

Acta Physica Sinica•Jan 1, 2015•0 citations

Towards miniaturized strontium optical lattice clock

Wei He

Optical atomic clocks with precisions and accuracies in the \n10\\(^-\\)\\(^1\\)\\(^8\\) level [1] are now the most advanced man-made timekeeping devices. They outperform the microwave cesium atomic clocks that realize the SI definition of the second. Scaling down the size of optical atomic clocks may open the door to a range of industrial and space applications. \n \nIn this thesis, the design and preliminary results of a compact strontium cooling system are presented. In the first cooling stage, the high power 461 nm laser with 300 mW output features a modular design, while smaller laser sources for demonstrating a strontium magneto-optical trap have also been investigated. An innovative design that couples a spectroscopy cell directly into the scientific chamber reduces the overall size and power consumption of the system. Additionally, using strontium oxide as a source of strontium atoms suitable for optical clocks has achieved initial success. For the first time, a single-beam MOT configuration is applied to strontium. In this novel apparatus, the blue MOT and red MOT broadband cooling phases are able to trap 5x10\\(^6\\) and 1000 atoms, respectively. This work shows promising progress towards developing a functional miniaturized strontium optical lattice clock.

•Jul 1, 2017•5 citations

Prospect for a compact strontium optical lattice clock

N. Poli, Robert E. Drullinger, G. Ferrari +4 more

We report on our progress toward the realization of a compact optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of the 1S0-3P0 doubly forbidden transition we have prepared a 698 nm clock laser stabilized on a high finesse, symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. Due to their compactness, reliability, and low power consumption, semiconductor laser sources represent the best choice for the development of compact and transportable devices for application both on Earth and in Space. A new Sr trapping and cooling experimental setup is also presented.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•9 citations

Optical frequency metrology with optical lattice clocks and optical frequency combs

Feng-Lei Hong, Masami Yasuda, Daisuke Akamatsu +5 more

Laser frequency stabilization and atom manipulation are important techniques for optical frequency metrology. We report on the development of an ytterbium (171Yb) and a strontium (87Sr) optical lattice clock at the National Metrology Institute of Japan (NMIJ). The result of absolute frequency measurement of the171Yb lattice clock is shown. We also report on narrow-linewidth fiber-based frequency combs that are used not only to measure the absolute frequency of the optical lattice clocks but also to servo control the frequency of the lasers for cooling and trapping Yb and Sr atoms.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•1 citation

Precision spectroscopy of cold strontium atoms, towards optical atomic clock

Marcin Bober, Jerzy Zachorowski, Wojciech Gawlik +10 more

Abstract This report concerns the experiment of precision spectroscopy of cold strontium atoms in the Polish National Laboratory of Atomic, Molecular and Optical Physics in Toruń. The system is composed of a Zeeman slower and magneto-optical traps (at 461 nm and 689 nm), a frequency comb, and a narrow-band laser locked to an ultra-stable optical cavity. All parts of the experiment are prepared and the first measurements of the absolute frequency of the 1S0-3P1, 689 nm optical transition in 88Sr atoms are performed.

Bulletin of the Polish Academy of Sciences Technical Sciences•Dec 1, 2012•6 citations
At present the optical clock with accuracy and stability achieves to 10-18 level, which could be the next generation of time and frequency standard. This paper gives an introduction of the progress of researching on the optical lattice clock of Strontium atom in NTSC (National Time Service Center). We realize the (5s5s)1S0—(5s5p)1P1 cooling (blue MOT) and (5s5s)1S0—(5s5p)3P1 cooling (red MOT) in succession for the optical lattice clock, and loading these cold atoms in a lattice composed by a magic wave-length is studied. By using our narrow line-width diode laser and the fiber femtosecond optical frequency comb, we precisely measure the absolute frequencies of the inter-combination transitions (5s5s)1S0—(5s5p)3P1 of four isotopes of Strontium referenced to an H maser.
We review recent experimental progress concerning the 87Sr optical lattice clock at the National Time Service Center in China. Hertz-level spectroscopy of the 87Sr clock transition for the optical lattice clock was performed, and closed-loop operation of the optical lattice clock was realized. A fractional frequency instability of 2.8 × 10−17 was attained for an averaging time of 2000 s. The Allan deviation is found to be 1.6 × 10−15/τ1/2 and is limited mainly by white-frequency-noise. The Landé g-factors of the (5s2)1S0 and (5s5p)3P0 states in 87Sr were measured experimentally; they are important for evaluating the clock’s Zeeman shifts. We also present recent work on the miniaturization of the strontium optical lattice clock for space applications.
The optical lattice clock with neutral atoms occupies an outstanding position in the research field of atomic clocks, demonstrating the great potential of its performance (like the uncertainty and the stability). At present, the optical lattice clock has realized a 10-18 level of its uncertainty. In this paper, we present the realization of loading bosonic atoms 88Sr (strontium, alkaline-earth metals) into a one-dimensional (1D) optical lattice in our laboratory. The optical lattice where the atoms are trapped can make the energy level shift, called Stark shift. But there is the special optical lattice operating at the “magic” wavelength for clock transitions (5s2) 1S0-(5s5p) 3P0, which can make the same Stark light-shift for both of them, indicating a zero light-shift relative to the clock. In our experiment, Sr atoms are cooled in a two-stage cooling and its temperature can be as low as 2 μK. Then these cold atoms are confined in the Lamb-Dicke region by the lattice laser output from an amplified diode laser operating at the “magic” wavelength, 813 nm. Experimentally, it is straightforward to provide 850 mW of lattice power focused to a 38 μm beam radius. After the cold atoms have trapped in the optical lattice, the lifetime of atoms in 1D optical lattice is measured to be 270 ms. The temperature and the number are about 3.5 μK and 1.2×105 respectively. Besides, effects of the power of the lattice laser on both the number and temperature are analyzed. The number changes linearly with the laser power, while there is no obvious influence on the temperature by the power. This original and special approach for atoms trapped in the optical lattice can provide a long interrogation time for probing the clock transition. Furthermore, it may be the foundation for developing our optical lattice clock of strontium atoms.
Optical atomic clocks with precisions and accuracies in the \n10\\(^-\\)\\(^1\\)\\(^8\\) level [1] are now the most advanced man-made timekeeping devices. They outperform the microwave cesium atomic clocks that realize the SI definition of the second. Scaling down the size of optical atomic clocks may open the door to a range of industrial and space applications. \n \nIn this thesis, the design and preliminary results of a compact strontium cooling system are presented. In the first cooling stage, the high power 461 nm laser with 300 mW output features a modular design, while smaller laser sources for demonstrating a strontium magneto-optical trap have also been investigated. An innovative design that couples a spectroscopy cell directly into the scientific chamber reduces the overall size and power consumption of the system. Additionally, using strontium oxide as a source of strontium atoms suitable for optical clocks has achieved initial success. For the first time, a single-beam MOT configuration is applied to strontium. In this novel apparatus, the blue MOT and red MOT broadband cooling phases are able to trap 5x10\\(^6\\) and 1000 atoms, respectively. This work shows promising progress towards developing a functional miniaturized strontium optical lattice clock.
We report on our progress toward the realization of a compact optical frequency standard referenced to strontium intercombination lines. Our current setup allows the production of ultracold Sr atoms in hundreds of ms. For high resolution spectroscopy of the 1S0-3P0 doubly forbidden transition we have prepared a 698 nm clock laser stabilized on a high finesse, symmetrically suspended cavity and a high power 813 nm light source for the optical lattice trap at the magic wavelength. Due to their compactness, reliability, and low power consumption, semiconductor laser sources represent the best choice for the development of compact and transportable devices for application both on Earth and in Space. A new Sr trapping and cooling experimental setup is also presented.
Laser frequency stabilization and atom manipulation are important techniques for optical frequency metrology. We report on the development of an ytterbium (171Yb) and a strontium (87Sr) optical lattice clock at the National Metrology Institute of Japan (NMIJ). The result of absolute frequency measurement of the171Yb lattice clock is shown. We also report on narrow-linewidth fiber-based frequency combs that are used not only to measure the absolute frequency of the optical lattice clocks but also to servo control the frequency of the lasers for cooling and trapping Yb and Sr atoms.
Abstract This report concerns the experiment of precision spectroscopy of cold strontium atoms in the Polish National Laboratory of Atomic, Molecular and Optical Physics in Toruń. The system is composed of a Zeeman slower and magneto-optical traps (at 461 nm and 689 nm), a frequency comb, and a narrow-band laser locked to an ultra-stable optical cavity. All parts of the experiment are prepared and the first measurements of the absolute frequency of the 1S0-3P1, 689 nm optical transition in 88Sr atoms are performed.