Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Frequency and Time Forum

Progress towards a strontium optical lattice clock at NPL

Elizabeth M. Bridge, Ian R. Hill, Yuri B. Ovchinnikov, G. P. Barwood, E. A. Curtis, Patrick Robert Gill

Published Apr 1, 2010• 0 citations
Publisher

Abstract

The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].

DOI
10.1109/eftf.2010.6533688

Related papers

Development of a neutral strontium lattice trap optical clock at the National Physical Laboratory

E. A. Curtis, G. P. Barwood, Yu. B. Ovchinnikov +2 more

The1S0-3P0transition in neutral strontium is being considered as one of the choices for the future redefinition of the SI second. At the National Physical Laboratory we are designing and implementing an optical clock based on this transition, holding the atoms in an optical lattice during the clock interrogation cycle, which greatly increases the potential accuracy of the clock. Our focus is on building a compact experimental system (including a novel permanent-magnet-based Zeeman slower) designed with the ability to assess systematic frequency shifts in mind, especially those related to blackbody radiation. Further study of systematic effects and additional intercomparisons of experimental results from different laboratories are being pursued with a view to gaining support for a future redefinition.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•0 citations

DEVELOPMENT OF AN OPTICAL CLOCK BASED ON NEUTRAL STRONTIUM ATOMS HELD IN A LATTICE TRAP

E. A. Curtis, Yuri B. Ovchinnikov, Ian R. Hill +2 more

At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•9 citations

Precision frequency metrology with optical lattice clocks

William Bowden

Strontium optical lattice clocks are proven to be excellent timekeepers. Their exceptional performance makes them a leading candidate for possible redefinition of the SI second and a valuable tool for searching for new physics beyond the standard model. This thesis reports on the development of strontium (Sr) optical lattice clocks at National Physical Laboratory (NPL).

•Jan 1, 2019•0 citations

Optical lattice clock on bosonic Strontium atoms

N. Poli, Marco G. Tarallo, M. Schioppo +4 more

We report on recent realization of an optical lattice clock operating on the1S0-3P0transition in88Sr, at LENS laboratories. The clock transition is excited with the technique of magnetic field-induced spectroscopy. New experimental techniques has also been developed in order to simplifies the clock spectroscopy in Sr atoms. The first new method helps in the first search of the clock transition without the use of extensive frequency metrology hardware and in particular optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0-3P0clock and1S0-3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger cooling transition. Secondly we reduce the complexity of the experimental setup by using only semiconductor laser sources in the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. We will present a first uncertainty budget for our optical lattice clock based on88Sr with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times. In view of an absolute frequency measurement of clock transition we'll also present recent experimental results on optimization of an home made Ti:Sa optical frequency comb. Additionally, we anticipate that the simplification of the experimental setup presented will help address a wider range of applications including those requiring transportable devices. Along these lines we will report progress on the realization of the first transportable Sr optical lattice clock.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•1 citation

Towards a strontium based stationary optical lattice clock

Qasim Hassan Ubaid

Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.

•Jul 20, 2020•0 citations
The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].
The1S0-3P0transition in neutral strontium is being considered as one of the choices for the future redefinition of the SI second. At the National Physical Laboratory we are designing and implementing an optical clock based on this transition, holding the atoms in an optical lattice during the clock interrogation cycle, which greatly increases the potential accuracy of the clock. Our focus is on building a compact experimental system (including a novel permanent-magnet-based Zeeman slower) designed with the ability to assess systematic frequency shifts in mind, especially those related to blackbody radiation. Further study of systematic effects and additional intercomparisons of experimental results from different laboratories are being pursued with a view to gaining support for a future redefinition.
At the National Physical Laboratory we are developing a neutral atom optical clock based on strontium atoms held in an optical lattice during the clock frequency measurement. The innovation of lattice-type clocks has greatly reduced velocity-related systematic frequency shifts compared to ballistic expansion neutral atom clocks. However, with predicted fractional uncertainties as low as 10 -18 , many previously unexplored systematic effects become relevant, especially in dealing with shifts due to blackbody radiation. We are designing a compact, diode-laser-based system, with a view to future transportable systems, and which includes a novel permanent-magnet-based Zeeman slower and a blackbody measurement chamber.
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.
We report on recent realization of an optical lattice clock operating on the1S0-3P0transition in88Sr, at LENS laboratories. The clock transition is excited with the technique of magnetic field-induced spectroscopy. New experimental techniques has also been developed in order to simplifies the clock spectroscopy in Sr atoms. The first new method helps in the first search of the clock transition without the use of extensive frequency metrology hardware and in particular optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0-3P0clock and1S0-3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger cooling transition. Secondly we reduce the complexity of the experimental setup by using only semiconductor laser sources in the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. We will present a first uncertainty budget for our optical lattice clock based on88Sr with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times. In view of an absolute frequency measurement of clock transition we'll also present recent experimental results on optimization of an home made Ti:Sa optical frequency comb. Additionally, we anticipate that the simplification of the experimental setup presented will help address a wider range of applications including those requiring transportable devices. Along these lines we will report progress on the realization of the first transportable Sr optical lattice clock.
Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.