Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Microwave Theory and Techniques

A 850-GHz waveguide receiver employing a niobium SIS junction fabricated on a 1-μm Si/sub 3/N/sub 4/ membrane

J. Kooi, Jérôme Pety, B. Bumble, C. K. Walker, Henry George LeDuc, P.L. Schaffer, Tom G. Phillips

Published Jan 1, 1998• 21 citations
Publisher

Abstract

We report on a 850-GHz superconducting-insulator-superconducting (SIS) heterodyne receiver employing an RF-tuned niobium tunnel junction with a current density of 14 kA/cm^2, fabricated on a 1-µm Si_3N_4 supporting membrane. Since the mixer is designed to be operated well above the superconducting gap frequency of niobium (2Δ/h ≈ 690 GHz), special care has been taken to minimize niobium transmission-line losses. Both Fourier transform spectrometer (FTS) measurements of the direct detection performance and calculations of the IF output noise with the mixer operating in heterodyne mode, indicate an absorption loss in the niobium film of about 6.8 dB at 822 GHz. These results are in reasonably good agreement with the loss predicted by the Mattis-Bardeen theory in the extreme anomalous limit. From 800 to 830 GHz, we report uncorrected receiver noise temperatures of 518 or 514 K when we use Callen and Welton's law to calculate the input load temperatures. Over the same frequency range, the mixer has a 4-dB conversion loss and 265 K ± 10 K noise temperature. At 890 GHz, the sensitivity of the receiver has degraded to 900 K, which is primarily the result of increased niobium film loss in the RF matching network. When the mixer was cooled from 4.2 to 1.9 K, the receiver noise temperature improved about 20% 409-K double sideband (DSB). Approximately half of the receiver noise temperature improvement can be attributed to a lower mixer conversion loss, while the remainder is due to a reduction in the niobium film absorption loss. At 982 GHz, we measured a receiver noise temperature of 1916 K.

DOI
10.1109/22.660981

Related papers

A 850 GHz SIS receiver employing silicon micro-machining technology

J. Kooi, Jérôme Pety, Paul Schaffer⧧ +4 more

A 850 GHz superconductor-insulator-superconductor (SIS) heterodyne receiver which uses a radiofrequency tuned niobium tunnel junction fabricated on a 1 micron thick silicon nitrate membrane, is reported. From video and heterodyne measurements, it was calculated that the niobium film loss in the radiofrequency matching network is about 6.8 dB at 822 GHz. These results are approximately a factor of two higher than the theoretical loss predicted by the Mattis-Bardeen theory in the extreme anomalous limit. The junction design and the receiver configuration are described, including the mixer block, the membrane construction and the cooled optics. The performance tests using a Fourier transform spectrometer to measure the response of the radiofrequency matching network, and the SIS simulations of the receiver response to cold and hot loads, the infrared noise contribution and the overall mixer conversion efficiency, are reported. It is concluded that the receiver response is limited by the absorption loss in the radiofrequency matching network.

ESASP•Dec 1, 1996•0 citations

A 665 GHz Waveguide Receiver Using a Tuned 0.5 μm 2 Nb/AlO x /Nb SIS Tunnel Junction

J. Kooi, Mansun Chan, Henry George LeDuc +1 more

We report recent results on a 580-740 GHz SIS heterodyne receiver employing a tuned 0.50Am Nb/A10x/Nb SIS tunnel junction. The receiver has been successfully installed at the Caltech Submillimeter Observatory, Hawaii. Results of an untuned device in the same waveguide block were presented at the fifth International THz Conference. Since the mixer is meant to be operated near the superconducting gap frequency of niobium (2,L/h 690 GHz), special has been taken to minimize the absorption loss in the rf matching network. To this effect we propose the use of a RF matching network that constitutes a hybrid between the well know end-loaded stub and radial stub matching networks. We have measured uncorrected DSB receiver temperatures as low as 160K from 680to 702 Gliz, 200K at 725GHz and 120K from 585-640 GHz. The uncorrected mixer noise temperature at 702 Gliz is about 125K, of which 62K can be directly contributed to the front end optics loss. Mixer conversion loss at 702 GHz is 7dB, of which 0.9dB is due to the absorption loss in the Nb film. This results in a corrected mixer noise temperature of 63K, 1.7 times the quantum noise limit.

Softwaretechnik-Trends•Mar 1, 1996•1 citation

Low-noise THz Niobium SIS Mixers

Mei Bin

This thesis describes the development of low-noise heterodyne receivers at THz frequencies for submillimeter astronomy using Nb-based superconductor-insulator-superconductor (SIS) tunneling junctions. The mixers utilize a quasi-optical configuration which consists of a planar twin-slot antenna and antisymmetrically-fed two-junctions on an antireflection-coated silicon hyperhemispherical lens. On-chip integrated tuning circuits, in the form of microstrip lines, are used to obtain maximum coupling efficiency in the designed frequency band. To reduce the rf losses in the integrated tuning circuits above the superconducting Nb gap frequency (~ 700 GHz), normal-metal Al is used to replace Nb as the tuning circuits. To account the rf losses in the micros trip lines, we calculated the surface impedance of the AI films using the nonlocal anomalous skin effect for finite thickness films. Nb films were calculated using the Mattis-Bardeen theory in the extreme anomalous limit. Our calculations show that the losses of the Al and Nb microstrip lines are about equal at 830 GHz. For Al-wiring and Nb-wiring mixers both optimized at 1050 GHz, the RF coupling efficiency of Al-wiring mixer is higher than that of Nb-wiring one by almost 50%. We have designed both Nb-wiring and Al-wiring mixers below and above the gap frequency. A Fourier transform spectrometer (FTS) has been constructed especially for the study of the frequency response of SIS receivers. This FTS features large aperture size (10 inch) and high frequency resolution (114 MHz). The FTS spectra, obtained using the SIS receivers as direct detectors on the FTS, agree quite well with our theoretical simulations. We have also, for the first time, measured the FTS heterodyne response of an SIS mixer at sufficiently high resolution to resolve the LO and the sidebands. Heterodyne measurements of our SIS receivers with Nb-wiring or Al-wiring have yielded results which arc among the best reported to date for broadband heterodyne receivers. The Nb-wiring mixers, covering 400 - 850 GHz band with four separate fixed-tuned mixers, have uncorrected DSB receiver noise temperature around 5hv/kb to 700 GHz, and better than 540 K at 808 GHz. An Al-wiring mixer designed for 1050 GHz band has an uncorrected DSB receiver noise temperature 840 K at 1042 GHz and 2.5 K bath temperature. Mixer performance analysis shows that Nb junctions can work well up to twice the gap frequency and the major cause of loss above the gap frequency is the rf losses in the microstrip tuning structures. Further advances in THz SIS mixers may be possible using circuits fabricated with higher-gap superconductors such as NbN. However, this will require high-quality films with low RF surface resistance at THz frequencies.

•Jul 18, 2014•8 citations

A 547 GHz SIS receiver employing a submicron Nb junction with an integrated matching circuit

Pascal Febvre, William R. McGrath, P. D. Batelaan +4 more

A heterodyne receiver using an SIS (superconductor-insulator-superconductor) waveguide mixer with two mechanical tuners has been built and characterized over the frequency range of 460 GHz to 630 GHz. This receiver is designed for radioastronomy applications. The mixer uses high-current-density, 0.25- mu m/sup 2/, Nb/AlO/sub x//Nb SIS tunnel junctions with integrated superconductive RF circuits to tune the junction capacitance. A DSB (double sideband) receiver noise temperature as low as 200+or-17 K has been obtained at 540 GHz. In addition, negative differential resistance has been observed in the DC I-V (current-voltage) curve at 487-491 GHz.>

IEEE MTT-S International Microwave Symposium digest•Dec 30, 2002•4 citations

An SIS Mixer With 2hf/k DSB Noise Temperature at 163 - 211 GHz Band

Bhushan Billade, Alexey Pavolotsky, Victor Y. Belitsky

We present the design and the performance of a fixed-tuned, all niobium (Nb) Superconductor-Insulator-Superconductor (SIS) mixer covering RF frequencies from 163 to 211 GHz with 4-8 GHz IF bandwidth. The mixer uses two Nb/Al-AlOx/Nb junctions of size 3 μm2each with theRnAproduct of 30 Ω·μm2, in a twin junction configuration. An local oscillator (LO) directional coupler made of superconducting lines with slots in the ground plane is integrated on the SIS mixer chip. The isolated port of the LO coupler is terminated using a wide-band resistive load with a sheet resistance of 12 Ω/□. The SIS tuning circuitry is optimized to achieve best power match between the twin junctions and the embedding circuitry. The measurement of the double sideband mixer noise at 171 GHz shows that the receiver noise temperature is approximately 17 K, which is just 2hf/k. The estimated noise contribution from the RF loss and the IF chain at 176 GHz LO frequency is 8 K and 7.5 K respectively, resulting in a SIS mixer noise ofhf/2k. The mixer noise performance across the entire RF band varies between 19 to 25 K. This is to our knowledge the best reported noise temperature at these frequencies till now.

IEEE Transactions on Terahertz Science and Technology•May 2, 2013•21 citations

A wideband fixed-tuned SIS receiver for 200-GHz operation

R. Blundell, Edward Tong, D. C. Papa +6 more

We report on the design and development of a heterodyne receiver, designed to cover the frequency range 176-256 GHz. This receiver incorporates a niobium superconductor-insulator-superconductor (SIS) tunnel junction mixer, which, chiefly for reasons of reliability and ease of operation, is a fixed-tuned waveguide design. On-chip tuning is provided to resonate out the junction's geometric capacitance and produce a good match to the waveguide circuit. Laboratory measurements on the first test receiver indicate that the required input bandwidth (about 40%) is achieved with an average receiver noise temperature of below 50 K. Mixer conversion gain is observed at some frequencies, and the lowest measured receiver noise is less than 30 K. Furthermore, the SIS mixer used in this receiver is of simple construction, is easy to assemble and is therefore a good candidate for duplication.>

IEEE Transactions on Microwave Theory and Techniques•Apr 1, 1995•69 citations
We report on a 850-GHz superconducting-insulator-superconducting (SIS) heterodyne receiver employing an RF-tuned niobium tunnel junction with a current density of 14 kA/cm^2, fabricated on a 1-µm Si_3N_4 supporting membrane. Since the mixer is designed to be operated well above the superconducting gap frequency of niobium (2Δ/h ≈ 690 GHz), special care has been taken to minimize niobium transmission-line losses. Both Fourier transform spectrometer (FTS) measurements of the direct detection performance and calculations of the IF output noise with the mixer operating in heterodyne mode, indicate an absorption loss in the niobium film of about 6.8 dB at 822 GHz. These results are in reasonably good agreement with the loss predicted by the Mattis-Bardeen theory in the extreme anomalous limit. From 800 to 830 GHz, we report uncorrected receiver noise temperatures of 518 or 514 K when we use Callen and Welton's law to calculate the input load temperatures. Over the same frequency range, the mixer has a 4-dB conversion loss and 265 K ± 10 K noise temperature. At 890 GHz, the sensitivity of the receiver has degraded to 900 K, which is primarily the result of increased niobium film loss in the RF matching network. When the mixer was cooled from 4.2 to 1.9 K, the receiver noise temperature improved about 20% 409-K double sideband (DSB). Approximately half of the receiver noise temperature improvement can be attributed to a lower mixer conversion loss, while the remainder is due to a reduction in the niobium film absorption loss. At 982 GHz, we measured a receiver noise temperature of 1916 K.
A 850 GHz superconductor-insulator-superconductor (SIS) heterodyne receiver which uses a radiofrequency tuned niobium tunnel junction fabricated on a 1 micron thick silicon nitrate membrane, is reported. From video and heterodyne measurements, it was calculated that the niobium film loss in the radiofrequency matching network is about 6.8 dB at 822 GHz. These results are approximately a factor of two higher than the theoretical loss predicted by the Mattis-Bardeen theory in the extreme anomalous limit. The junction design and the receiver configuration are described, including the mixer block, the membrane construction and the cooled optics. The performance tests using a Fourier transform spectrometer to measure the response of the radiofrequency matching network, and the SIS simulations of the receiver response to cold and hot loads, the infrared noise contribution and the overall mixer conversion efficiency, are reported. It is concluded that the receiver response is limited by the absorption loss in the radiofrequency matching network.
We report recent results on a 580-740 GHz SIS heterodyne receiver employing a tuned 0.50Am Nb/A10x/Nb SIS tunnel junction. The receiver has been successfully installed at the Caltech Submillimeter Observatory, Hawaii. Results of an untuned device in the same waveguide block were presented at the fifth International THz Conference. Since the mixer is meant to be operated near the superconducting gap frequency of niobium (2,L/h 690 GHz), special has been taken to minimize the absorption loss in the rf matching network. To this effect we propose the use of a RF matching network that constitutes a hybrid between the well know end-loaded stub and radial stub matching networks. We have measured uncorrected DSB receiver temperatures as low as 160K from 680to 702 Gliz, 200K at 725GHz and 120K from 585-640 GHz. The uncorrected mixer noise temperature at 702 Gliz is about 125K, of which 62K can be directly contributed to the front end optics loss. Mixer conversion loss at 702 GHz is 7dB, of which 0.9dB is due to the absorption loss in the Nb film. This results in a corrected mixer noise temperature of 63K, 1.7 times the quantum noise limit.
This thesis describes the development of low-noise heterodyne receivers at THz frequencies for submillimeter astronomy using Nb-based superconductor-insulator-superconductor (SIS) tunneling junctions. The mixers utilize a quasi-optical configuration which consists of a planar twin-slot antenna and antisymmetrically-fed two-junctions on an antireflection-coated silicon hyperhemispherical lens. On-chip integrated tuning circuits, in the form of microstrip lines, are used to obtain maximum coupling efficiency in the designed frequency band. To reduce the rf losses in the integrated tuning circuits above the superconducting Nb gap frequency (~ 700 GHz), normal-metal Al is used to replace Nb as the tuning circuits. To account the rf losses in the micros trip lines, we calculated the surface impedance of the AI films using the nonlocal anomalous skin effect for finite thickness films. Nb films were calculated using the Mattis-Bardeen theory in the extreme anomalous limit. Our calculations show that the losses of the Al and Nb microstrip lines are about equal at 830 GHz. For Al-wiring and Nb-wiring mixers both optimized at 1050 GHz, the RF coupling efficiency of Al-wiring mixer is higher than that of Nb-wiring one by almost 50%. We have designed both Nb-wiring and Al-wiring mixers below and above the gap frequency. A Fourier transform spectrometer (FTS) has been constructed especially for the study of the frequency response of SIS receivers. This FTS features large aperture size (10 inch) and high frequency resolution (114 MHz). The FTS spectra, obtained using the SIS receivers as direct detectors on the FTS, agree quite well with our theoretical simulations. We have also, for the first time, measured the FTS heterodyne response of an SIS mixer at sufficiently high resolution to resolve the LO and the sidebands. Heterodyne measurements of our SIS receivers with Nb-wiring or Al-wiring have yielded results which arc among the best reported to date for broadband heterodyne receivers. The Nb-wiring mixers, covering 400 - 850 GHz band with four separate fixed-tuned mixers, have uncorrected DSB receiver noise temperature around 5hv/kb to 700 GHz, and better than 540 K at 808 GHz. An Al-wiring mixer designed for 1050 GHz band has an uncorrected DSB receiver noise temperature 840 K at 1042 GHz and 2.5 K bath temperature. Mixer performance analysis shows that Nb junctions can work well up to twice the gap frequency and the major cause of loss above the gap frequency is the rf losses in the microstrip tuning structures. Further advances in THz SIS mixers may be possible using circuits fabricated with higher-gap superconductors such as NbN. However, this will require high-quality films with low RF surface resistance at THz frequencies.
A heterodyne receiver using an SIS (superconductor-insulator-superconductor) waveguide mixer with two mechanical tuners has been built and characterized over the frequency range of 460 GHz to 630 GHz. This receiver is designed for radioastronomy applications. The mixer uses high-current-density, 0.25- mu m/sup 2/, Nb/AlO/sub x//Nb SIS tunnel junctions with integrated superconductive RF circuits to tune the junction capacitance. A DSB (double sideband) receiver noise temperature as low as 200+or-17 K has been obtained at 540 GHz. In addition, negative differential resistance has been observed in the DC I-V (current-voltage) curve at 487-491 GHz.>
We present the design and the performance of a fixed-tuned, all niobium (Nb) Superconductor-Insulator-Superconductor (SIS) mixer covering RF frequencies from 163 to 211 GHz with 4-8 GHz IF bandwidth. The mixer uses two Nb/Al-AlOx/Nb junctions of size 3 μm2each with theRnAproduct of 30 Ω·μm2, in a twin junction configuration. An local oscillator (LO) directional coupler made of superconducting lines with slots in the ground plane is integrated on the SIS mixer chip. The isolated port of the LO coupler is terminated using a wide-band resistive load with a sheet resistance of 12 Ω/□. The SIS tuning circuitry is optimized to achieve best power match between the twin junctions and the embedding circuitry. The measurement of the double sideband mixer noise at 171 GHz shows that the receiver noise temperature is approximately 17 K, which is just 2hf/k. The estimated noise contribution from the RF loss and the IF chain at 176 GHz LO frequency is 8 K and 7.5 K respectively, resulting in a SIS mixer noise ofhf/2k. The mixer noise performance across the entire RF band varies between 19 to 25 K. This is to our knowledge the best reported noise temperature at these frequencies till now.
We report on the design and development of a heterodyne receiver, designed to cover the frequency range 176-256 GHz. This receiver incorporates a niobium superconductor-insulator-superconductor (SIS) tunnel junction mixer, which, chiefly for reasons of reliability and ease of operation, is a fixed-tuned waveguide design. On-chip tuning is provided to resonate out the junction's geometric capacitance and produce a good match to the waveguide circuit. Laboratory measurements on the first test receiver indicate that the required input bandwidth (about 40%) is achieved with an average receiver noise temperature of below 50 K. Mixer conversion gain is observed at some frequencies, and the lowest measured receiver noise is less than 30 K. Furthermore, the SIS mixer used in this receiver is of simple construction, is easy to assemble and is therefore a good candidate for duplication.>