Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Frequency stability characterisation of a strontium trapped ion optical frequency standard

G. P. Barwood, Patrick Robert Gill, Guozheng Huang, Hugh A. Klein

Published Jun 1, 2008• 0 citations
Publisher

Abstract

Two 674-nm optical frequency standards based on the2S1/2-2D5/2transition in88Sr+are under development at NPL. Comparison of the standards allows determination of the frequency stability and reproducibility via difference frequency measurements. A relative frequency stability between the traps of ap3times10-15over a 100 s averaging time has been observed. A compact, transportable system is also being developed, which could find application in ground stations or as an optical frequency clock in space.

DOI
10.1109/cpem.2008.4574653

Related papers

Single Trapped Ions for Optical Frequency Standards

Hugh A. Klein, G. P. Barwood, Patrick Robert Gill +1 more

A number of laboratories are working towards developing optical frequency standards based on single trapped ions. The options are briefly reviewed. Recent progress using the singly ionised strontium system at the National Physical Laboratory (NPL) is outlined. A comparison of the frequency of the 2 S 1/2 – 2 D 5/2 transition at 674 nm in 88 Sr + , observed simultaneously in two traps, showed agreement at the 3 parts in 10 13 level. The possibility of cooling and probing 87 Sr + has recently been proposed because it offers a 674 nm transition between m F = 0 levels which is independent of magnetic field to first order. Trapping of 87 Sr + ions prepared using an oven containing an isotopically enriched strontium compound has been demonstrated at NPL.

Physica Scripta•Jan 1, 2000•5 citations

A STRONTIUM ION OPTICAL FREQUENCY STANDARD WITH Hz-LEVEL UNCERTAINTY

Helen S. Margolis, G. P. Barwood, Guozheng Huang +5 more

The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.

Laser Spectroscopy•Dec 1, 2005•1 citation

AN OPTICAL CLOCK BASED ON A SINGLE TRAPPED 88 Sr + ION

Helen S. Margolis, G. P. Barwood, G. HUANG +6 more

The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Extended precision measurements of a strontium single ion optical frequency standard and its development as an optical atomic clock

Alan A. Madej, P. Dubé, J. E. Bernard +4 more

We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•0 citations

Trapped Ion Optical Clocks at NPL

Helen S. Margolis, G. P. Barwood, K. Hosaka +7 more

Forbidden transitions in single laser‐cooled trapped ions provide highly stable and accurate references for optical frequency standards. This paper describes recent progress on strontium and ytterbium ion optical frequency standards under development at NPL.

AIP conference proceedings•Jan 1, 2006•5 citations

Study for a 43Ca+ Optical Frequency Standard

K. Matsubara, Kenji Toyoda, Y. Li +5 more

The authors proceed with a research and development of an optical frequency standard based on the2S1/2-2D5/2transition of43Ca+in a RF trap. For this purpose, motional sidebands of a single40Ca+ion were observed and a stable laser-diode system for spectroscopy of43Ca+are being developed

Conference on Precision Electromagnetic Measurements•Jun 1, 2004•3 citations
Two 674-nm optical frequency standards based on the2S1/2-2D5/2transition in88Sr+are under development at NPL. Comparison of the standards allows determination of the frequency stability and reproducibility via difference frequency measurements. A relative frequency stability between the traps of ap3times10-15over a 100 s averaging time has been observed. A compact, transportable system is also being developed, which could find application in ground stations or as an optical frequency clock in space.
A number of laboratories are working towards developing optical frequency standards based on single trapped ions. The options are briefly reviewed. Recent progress using the singly ionised strontium system at the National Physical Laboratory (NPL) is outlined. A comparison of the frequency of the 2 S 1/2 – 2 D 5/2 transition at 674 nm in 88 Sr + , observed simultaneously in two traps, showed agreement at the 3 parts in 10 13 level. The possibility of cooling and probing 87 Sr + has recently been proposed because it offers a 674 nm transition between m F = 0 levels which is independent of magnetic field to first order. Trapping of 87 Sr + ions prepared using an oven containing an isotopically enriched strontium compound has been demonstrated at NPL.
The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.
The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.
We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.