Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser Spectroscopy

A STRONTIUM ION OPTICAL FREQUENCY STANDARD WITH Hz-LEVEL UNCERTAINTY

Helen S. Margolis, G. P. Barwood, Guozheng Huang, Hugh A. Klein, S.N. Lea, K. HOSAKA, K. Szymaniec, Patrick Robert Gill

Published Dec 1, 2005• 1 citation
Publisher

Abstract

The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.

DOI
10.1142/9789812701473_0033

Related papers

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•301 citations

AN OPTICAL CLOCK BASED ON A SINGLE TRAPPED 88 Sr + ION

Helen S. Margolis, G. P. Barwood, G. HUANG +6 more

The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations

Measurement of the Electric Quadrupole Moment of the 4d D5/22 Level in Sr+88

G. P. Barwood, Helen S. Margolis, Guozheng Huang +2 more

The quadrupole moment of the 4d (2)D(5/2) level in 88Sr+ has been measured to be 2.6(3)ea(2)(0), where a(0) is the Bohr radius and e the elementary charge. A single laser-cooled strontium ion was confined in an end cap trap with a variable dc quadrupole potential, and measurements were made on the 5s (2)S(1/2)-4d (2)D(5/2) transition at 674 nm using a femtosecond optical frequency comb. This work shows that measurements of the unperturbed 88Sr+ transition frequency with sub-Hz uncertainty are possible and is important in understanding the reproducibility of ion trap optical frequency standards.

Physical Review Letters•Sep 22, 2004•79 citations

Single Trapped Ions for Optical Frequency Standards

Hugh A. Klein, G. P. Barwood, Patrick Robert Gill +1 more

A number of laboratories are working towards developing optical frequency standards based on single trapped ions. The options are briefly reviewed. Recent progress using the singly ionised strontium system at the National Physical Laboratory (NPL) is outlined. A comparison of the frequency of the 2 S 1/2 – 2 D 5/2 transition at 674 nm in 88 Sr + , observed simultaneously in two traps, showed agreement at the 3 parts in 10 13 level. The possibility of cooling and probing 87 Sr + has recently been proposed because it offers a 674 nm transition between m F = 0 levels which is independent of magnetic field to first order. Trapping of 87 Sr + ions prepared using an oven containing an isotopically enriched strontium compound has been demonstrated at NPL.

Physica Scripta•Jan 1, 2000•5 citations

Optical frequency standard based on a trapped171Yb+ion

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 2003•0 citations
The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.
The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.
The quadrupole moment of the 4d (2)D(5/2) level in 88Sr+ has been measured to be 2.6(3)ea(2)(0), where a(0) is the Bohr radius and e the elementary charge. A single laser-cooled strontium ion was confined in an end cap trap with a variable dc quadrupole potential, and measurements were made on the 5s (2)S(1/2)-4d (2)D(5/2) transition at 674 nm using a femtosecond optical frequency comb. This work shows that measurements of the unperturbed 88Sr+ transition frequency with sub-Hz uncertainty are possible and is important in understanding the reproducibility of ion trap optical frequency standards.
A number of laboratories are working towards developing optical frequency standards based on single trapped ions. The options are briefly reviewed. Recent progress using the singly ionised strontium system at the National Physical Laboratory (NPL) is outlined. A comparison of the frequency of the 2 S 1/2 – 2 D 5/2 transition at 674 nm in 88 Sr + , observed simultaneously in two traps, showed agreement at the 3 parts in 10 13 level. The possibility of cooling and probing 87 Sr + has recently been proposed because it offers a 674 nm transition between m F = 0 levels which is independent of magnetic field to first order. Trapping of 87 Sr + ions prepared using an oven containing an isotopically enriched strontium compound has been demonstrated at NPL.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.