Symposium on Frequency Standards and Metrology

AN OPTICAL CLOCK BASED ON A SINGLE TRAPPED 88 Sr + ION

Helen S. Margolis, G. P. Barwood, G. HUANG, Hugh A. Klein, S.N. Lea, Giuseppe Marra, Veronika Tsatourian, Barney Walton, P. GILL

Published May 1, 2009• 0 citations
Publisher

Abstract

The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.

DOI
10.1142/9789812838223_0027

Related papers

A STRONTIUM ION OPTICAL FREQUENCY STANDARD WITH Hz-LEVEL UNCERTAINTY

Helen S. Margolis, G. P. Barwood, Guozheng Huang +5 more

The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.

Laser Spectroscopy•Dec 1, 2005•1 citation

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•301 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations

HIGH RESOLUTION SPECTROSCOPY OF A SINGLE In + ION

Th. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as a reference for a highly stable optical frequency standard. We present recent results of our work with single indium ions, using the 5 s 2 1 S 0 - 5 s 5 p 3 P 0 transition at a wavelength of 237 nm as the clock transition. This resonance has a linewidth of only 0.8 Hz where systematic shifts should be controllable at the mHz level. A single In + ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 µK. The clock transition is excited using a frequency quadrupled Nd:YAG laser emitting at 946 nm. A fractional resolution of 1.3 × 10 -13 has been achieved so far (linewidth of 170 Hz at 1267 THz), limited by the frequency instability of the Nd :YAG laser. The absolute frequency of the clock transition has been measured with an uncertainty of 2 × 10 -13 using a phase-coherent frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated against an atomic cesium fountain clock.

Symposium on Frequency Standards and Metrology•May 1, 2002•1 citation

Indium single ion optical frequency standard

T. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•3 citations

Single Trapped Ions for Optical Frequency Standards

Hugh A. Klein, G. P. Barwood, Patrick Robert Gill +1 more

A number of laboratories are working towards developing optical frequency standards based on single trapped ions. The options are briefly reviewed. Recent progress using the singly ionised strontium system at the National Physical Laboratory (NPL) is outlined. A comparison of the frequency of the 2 S 1/2 – 2 D 5/2 transition at 674 nm in 88 Sr + , observed simultaneously in two traps, showed agreement at the 3 parts in 10 13 level. The possibility of cooling and probing 87 Sr + has recently been proposed because it offers a 674 nm transition between m F = 0 levels which is independent of magnetic field to first order. Trapping of 87 Sr + ions prepared using an oven containing an isotopically enriched strontium compound has been demonstrated at NPL.

Physica Scripta•Jan 1, 2000•5 citations
The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.
The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.
A single laser cooled ion in a radiofrequency trap can serve as a reference for a highly stable optical frequency standard. We present recent results of our work with single indium ions, using the 5 s 2 1 S 0 - 5 s 5 p 3 P 0 transition at a wavelength of 237 nm as the clock transition. This resonance has a linewidth of only 0.8 Hz where systematic shifts should be controllable at the mHz level. A single In + ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 µK. The clock transition is excited using a frequency quadrupled Nd:YAG laser emitting at 946 nm. A fractional resolution of 1.3 × 10 -13 has been achieved so far (linewidth of 170 Hz at 1267 THz), limited by the frequency instability of the Nd :YAG laser. The absolute frequency of the clock transition has been measured with an uncertainty of 2 × 10 -13 using a phase-coherent frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated against an atomic cesium fountain clock.
A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.
A number of laboratories are working towards developing optical frequency standards based on single trapped ions. The options are briefly reviewed. Recent progress using the singly ionised strontium system at the National Physical Laboratory (NPL) is outlined. A comparison of the frequency of the 2 S 1/2 – 2 D 5/2 transition at 674 nm in 88 Sr + , observed simultaneously in two traps, showed agreement at the 3 parts in 10 13 level. The possibility of cooling and probing 87 Sr + has recently been proposed because it offers a 674 nm transition between m F = 0 levels which is independent of magnetic field to first order. Trapping of 87 Sr + ions prepared using an oven containing an isotopically enriched strontium compound has been demonstrated at NPL.