Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Advances in chip-scale atomic frequency references at NIST

Svenja A. Knappe, Vishal Shah, Alan S. Brannon, Vladislav P. Gerginov, H. G. Robinson, Zoya B. Popovic, Leo W. Hollberg, John E. Kitching

Published Aug 29, 2007• 9 citations
Publisher

Abstract

Coherent population trapping (CPT) resonances usually exhibit contrasts below 10% when interrogated with frequency modulated lasers. We discuss a relatively simple way to increase the resonance contrast to nearly 100% generating an additional light field through a nonlinear four-wave mixing interaction in the atomic vapor.1 A similar method can also be used to create a beat signal at the CPT resonance frequency that can injection-lock a low-power microwave oscillator at 3.4 GHz directly to the atomic resonance.2 This could lead to chip-scale atomic clocks (CSACs) with improved performance. Furthermore, we introduce a miniature microfabricated saturated absorption spectrometer3 that produces a signal for locking a laser frequency to optical transitions in alkali atoms. The Rb absorption spectra are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm3 and the volume of the entire spectrometer is around 0.1 cm3.

DOI
10.1117/12.735024

Related papers

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations

Microfabricated Atomic Clocks at NIST

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +5 more

This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.

•Dec 1, 2004•3 citations

The Microfabricated Alkali Vapor Cell with High Hermeticity for Chip-Scale Atomic Clock

Shuo Jia, Zhiyuan Jiang, Binbin Jiao +4 more

Herein, a microfabricated millimeter-level vapor alkali cell with a high hermeticity is fabricated through a wet etching and single-chip anodic bonding process. The vapor cell, containing Rb and N2, was investigated in a coherent population trapping (CPT) setup for the application of a chip-scale atomic clock (CSAC). The contrast of CPT resonance is up to 1.1% within the only 1 mm length of light interacting with atom. The effects of some critical external parameters on the CPT resonance, such as laser intensity, cell temperature, and buffer gas pressure, are thoroughly studied and optimized. The improved microfabricated vapor cell also exhibited great potential for other chip-scale atomic devices.

Applied Sciences•Jan 3, 2022•21 citations

Stabilization method for atomic clocks to detect the maximum coherent-population-trapping resonance signal

Yusuke Odagiri, Satoshi Hatano, Yuichiro Yano +3 more

Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.

Japanese Journal of Applied Physics•Jun 1, 2025•2 citations

Electromagnetically Induced Absorption for a Cesium Vapor-Cell Microwave Frequency Reference

Denis V. Brazhnikov, S M Ignatovich, V. I. Vishnyakov +2 more

The coherent population trapping (CPT) phenomenon1 has been widely used for the development of cell-based microwave frequency references, including the demonstration and even commercialization of chip-scale atomic clocks (MACs)2. In CPT physics, atoms are driven into adark state uncoupled from the excited state by making the atoms interact with a dual-frequency optical field such that the Raman detuning is null. CPT induces a reduction of the light field absorption in the vapor cell, leading to the detection of a resonance peak (increased transmission) in the bottom of the absorption line. The CPT dark resonance is usually excited in commercial MACs with a simple circularly polarized dualfrequency light field. Alternative excitation schemes have also been proposed.

•Apr 21, 2020•0 citations

Ramsey-CPT spectroscopy for a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +3 more

We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks

•Jul 7, 2021•0 citations
Coherent population trapping (CPT) resonances usually exhibit contrasts below 10% when interrogated with frequency modulated lasers. We discuss a relatively simple way to increase the resonance contrast to nearly 100% generating an additional light field through a nonlinear four-wave mixing interaction in the atomic vapor.1 A similar method can also be used to create a beat signal at the CPT resonance frequency that can injection-lock a low-power microwave oscillator at 3.4 GHz directly to the atomic resonance.2 This could lead to chip-scale atomic clocks (CSACs) with improved performance. Furthermore, we introduce a miniature microfabricated saturated absorption spectrometer3 that produces a signal for locking a laser frequency to optical transitions in alkali atoms. The Rb absorption spectra are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm3 and the volume of the entire spectrometer is around 0.1 cm3.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.
Herein, a microfabricated millimeter-level vapor alkali cell with a high hermeticity is fabricated through a wet etching and single-chip anodic bonding process. The vapor cell, containing Rb and N2, was investigated in a coherent population trapping (CPT) setup for the application of a chip-scale atomic clock (CSAC). The contrast of CPT resonance is up to 1.1% within the only 1 mm length of light interacting with atom. The effects of some critical external parameters on the CPT resonance, such as laser intensity, cell temperature, and buffer gas pressure, are thoroughly studied and optimized. The improved microfabricated vapor cell also exhibited great potential for other chip-scale atomic devices.
Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.
The coherent population trapping (CPT) phenomenon1 has been widely used for the development of cell-based microwave frequency references, including the demonstration and even commercialization of chip-scale atomic clocks (MACs)2. In CPT physics, atoms are driven into adark state uncoupled from the excited state by making the atoms interact with a dual-frequency optical field such that the Raman detuning is null. CPT induces a reduction of the light field absorption in the vapor cell, leading to the detection of a resonance peak (increased transmission) in the bottom of the absorption line. The CPT dark resonance is usually excited in commercial MACs with a simple circularly polarized dualfrequency light field. Alternative excitation schemes have also been proposed.
We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks