Electromagnetically Induced Absorption for a Cesium Vapor-Cell Microwave Frequency Reference

Denis V. Brazhnikov, S M Ignatovich, V. I. Vishnyakov, Rodolphe Boudot, Mikhail N Skvortsov

Published Apr 21, 2020• 0 citations
OpenAlex

Abstract

The coherent population trapping (CPT) phenomenon1 has been widely used for the development of cell-based microwave frequency references, including the demonstration and even commercialization of chip-scale atomic clocks (MACs)2. In CPT physics, atoms are driven into adark state uncoupled from the excited state by making the atoms interact with a dual-frequency optical field such that the Raman detuning is null. CPT induces a reduction of the light field absorption in the vapor cell, leading to the detection of a resonance peak (increased transmission) in the bottom of the absorption line. The CPT dark resonance is usually excited in commercial MACs with a simple circularly polarized dualfrequency light field. Alternative excitation schemes have also been proposed.

Related papers

Advances in chip-scale atomic frequency references at NIST

Svenja A. Knappe, Vishal Shah, Alan S. Brannon +5 more

Coherent population trapping (CPT) resonances usually exhibit contrasts below 10% when interrogated with frequency modulated lasers. We discuss a relatively simple way to increase the resonance contrast to nearly 100% generating an additional light field through a nonlinear four-wave mixing interaction in the atomic vapor.1 A similar method can also be used to create a beat signal at the CPT resonance frequency that can injection-lock a low-power microwave oscillator at 3.4 GHz directly to the atomic resonance.2 This could lead to chip-scale atomic clocks (CSACs) with improved performance. Furthermore, we introduce a miniature microfabricated saturated absorption spectrometer3 that produces a signal for locking a laser frequency to optical transitions in alkali atoms. The Rb absorption spectra are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm3 and the volume of the entire spectrometer is around 0.1 cm3.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•9 citations

Light shift mitigation in microcell-based coherent-population-trapping atomic clocks in the field of two circularly polarized light beams

Denis V. Brazhnikov, S M Ignatovich, Mikhail N Skvortsov

State-of-the-art miniature atomic clocks (MACs) are based on the phenomenon of coherent population trapping (CPT) in alkali-metal atomic vapors ($\mathrm{Rb}$ or $\mathrm{Cs}$). Improving the stability of the clock frequency is a crucial issue; resolving it would result in significant progress in numerous applications. Here, we examine the configuration of the light field, which is composed of two bichromatic beams with opposing handedness of circular polarization. The beams are in resonance with optical transitions in the $\mathrm{Cs}$ ${D}_{1}$ line ($\ensuremath{\lambda}\ensuremath{\approx}895$ nm). This configuration has previously been shown to produce observed CPT resonances with higher contrast than a standard single-beam scheme; however, our scheme implements pump and probe beams that operate independently, with the transmission of the probe beam being monitored separately. This approach differs from previous studies. The experiments are carried out using a cubic $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\phantom{\rule{0.2em}{0ex}}{\mathrm{mm}}^{3}$ vapor cell filled with buffer gas. It is shown that the line shape of the resonance acquires an asymmetry that can be efficiently controlled by a microwave (Raman) phase between the beams. As a proof of concept, we study the way in which this asymmetry can help to mitigate the influence of the ac Stark (light) shift on the long-term frequency stability of CPT clocks based on vapor microcells ($V\ensuremath{\ll}1\phantom{\rule{0.2em}{0ex}}{\mathrm{cm}}^{3}$). Experimental verification is performed with both a distributed-Bragg-reflector laser and a vertical-cavity surface-emitting laser. The latter is of particular importance for the development of MACs. The experimental results are in qualitative agreement with the analytical theory based on a double-$\mathrm{\ensuremath{\Lambda}}$ scheme of atomic energy levels.

arXiv:2311.00461•Physical Review Applied•May 23, 2024•9 citations

A frequency reference based in VCSEL-driven dark line resonances in Cs vapor

John E. Kitching, N. Vukičević, Weidermann +5 more

Summary form only given. We report on recent experiments to use dark line coherent population trapping (CPT) resonances in cesium vapor as the basis for a compact frequency reference. The resonance is excited by directly modulating the injection current of a VCSEL at one-half the ground state hyperfine transition of Cs (4.6 GHz) to produce RF sidebands on the optical carrier. The laser output is then passed through a room-temperature cell containing Cs at its vapor pressure together with 8.7 kPa of Neon buffer gas and the transmitted optical power is detected in a photodiode. When the laser carrier is tuned half way between the two hyperfine components of the D/sub 2/ line at 852 nm, and the RF modulation frequency is adjusted to be equal to one-half the hyperfine splitting, the absorption of the sidebands through the cell is slightly reduced due to the CPT effect. As the RF frequency is scanned over the resonance, lock-in detection is used to produce a /spl sim/1 kHz wide dispersive error signal which is in turn used to stabilize the modulation frequency. The narrow signal is the result of the buffer gas, which reduces the time-of-flight broadening of the transition.

Quantum Electronics and Laser Science Conference•Jan 1, 2000•1 citation

Frequency Shifts in a Coherent Population Trapping Cs Vapor Cell Atomic Clock

Juliette Breurec, Moustafa Abdel Hafiz, Claudio Eligio Calosso +2 more

We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•May 29, 2025•4 citations

Microwave phase detection of coherent population trapping resonance in a Cs vapor cell

Michael Petersen, Moustafa Abdel Hafiz, Emeric de Clercq +1 more

We report a phase-sensitive microwave detection setup for spectroscopy of coherent population trapping (CPT) resonance in a Cs vapor cell. In this scheme, the optically carried microwave interrogation signal that interacts with atoms is detected by a fast photodiode at the cell output and is then mixed with the local oscillator microwave signal itself. This detection scheme produces at the output of the microwave mixer a dispersive CPT signal that can be directly used for correction of the local oscillator frequency onto the atomic resonance. The evolution of the dispersive CPT resonance signal with the laser power is briefly reported. With this detection scheme, we demonstrate the operation of a CPT atomic clock with a short-term fractional frequency stability of 1 × 10 − 11 at 1 s, which is in good agreement with the slope of the frequency discriminator and the residual microwave phase noise of the setup.

Journal of the Optical Society of America B•Feb 3, 2022•3 citations

Lin || lin coherent population trapping and its application for vapor-cell-atomic-clocks

Evelina Breschi, Georgy A. Kazakov, Roland Lammegger +3 more

The authors presented investigations on the application of CPT effect as alternative to the traditional optical microwave double resonance in small atomic clocks. An important factor which may limit the performances of CPT-based atomic clocks is the reduced signal contrast as compared to optical pumping. To overcome this limit, several excitation schemes have been proposed in the last years. Particularly, a significant enhancement of the CPT contrast can be obtained when co-propagating laser waves with parallel linear polarization (lin | | lin CPT) are resonant with the excited state Fe=l of alkali atoms.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•2 citations
The coherent population trapping (CPT) phenomenon1 has been widely used for the development of cell-based microwave frequency references, including the demonstration and even commercialization of chip-scale atomic clocks (MACs)2. In CPT physics, atoms are driven into adark state uncoupled from the excited state by making the atoms interact with a dual-frequency optical field such that the Raman detuning is null. CPT induces a reduction of the light field absorption in the vapor cell, leading to the detection of a resonance peak (increased transmission) in the bottom of the absorption line. The CPT dark resonance is usually excited in commercial MACs with a simple circularly polarized dualfrequency light field. Alternative excitation schemes have also been proposed.
Coherent population trapping (CPT) resonances usually exhibit contrasts below 10% when interrogated with frequency modulated lasers. We discuss a relatively simple way to increase the resonance contrast to nearly 100% generating an additional light field through a nonlinear four-wave mixing interaction in the atomic vapor.1 A similar method can also be used to create a beat signal at the CPT resonance frequency that can injection-lock a low-power microwave oscillator at 3.4 GHz directly to the atomic resonance.2 This could lead to chip-scale atomic clocks (CSACs) with improved performance. Furthermore, we introduce a miniature microfabricated saturated absorption spectrometer3 that produces a signal for locking a laser frequency to optical transitions in alkali atoms. The Rb absorption spectra are comparable to signals obtained with standard table-top setups, although the rubidium vapor cell has an interior volume of only 1 mm3 and the volume of the entire spectrometer is around 0.1 cm3.
State-of-the-art miniature atomic clocks (MACs) are based on the phenomenon of coherent population trapping (CPT) in alkali-metal atomic vapors (Rb\mathrm{Rb}Rb or Cs\mathrm{Cs}Cs). Improving the stability of the clock frequency is a crucial issue; resolving it would result in significant progress in numerous applications. Here, we examine the configuration of the light field, which is composed of two bichromatic beams with opposing handedness of circular polarization. The beams are in resonance with optical transitions in the Cs\mathrm{Cs}Cs D1{D}_{1}D1​ line ($\ensuremath{\lambda}\ensuremath{\approx}895$ nm). This configuration has previously been shown to produce observed CPT resonances with higher contrast than a standard single-beam scheme; however, our scheme implements pump and probe beams that operate independently, with the transmission of the probe beam being monitored separately. This approach differs from previous studies. The experiments are carried out using a cubic $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\phantom{\rule{0.2em}{0ex}}{\mathrm{mm}}^{3}$ vapor cell filled with buffer gas. It is shown that the line shape of the resonance acquires an asymmetry that can be efficiently controlled by a microwave (Raman) phase between the beams. As a proof of concept, we study the way in which this asymmetry can help to mitigate the influence of the ac Stark (light) shift on the long-term frequency stability of CPT clocks based on vapor microcells ($V\ensuremath{\ll}1\phantom{\rule{0.2em}{0ex}}{\mathrm{cm}}^{3}$). Experimental verification is performed with both a distributed-Bragg-reflector laser and a vertical-cavity surface-emitting laser. The latter is of particular importance for the development of MACs. The experimental results are in qualitative agreement with the analytical theory based on a double-$\mathrm{\ensuremath{\Lambda}}$ scheme of atomic energy levels.
Summary form only given. We report on recent experiments to use dark line coherent population trapping (CPT) resonances in cesium vapor as the basis for a compact frequency reference. The resonance is excited by directly modulating the injection current of a VCSEL at one-half the ground state hyperfine transition of Cs (4.6 GHz) to produce RF sidebands on the optical carrier. The laser output is then passed through a room-temperature cell containing Cs at its vapor pressure together with 8.7 kPa of Neon buffer gas and the transmitted optical power is detected in a photodiode. When the laser carrier is tuned half way between the two hyperfine components of the D/sub 2/ line at 852 nm, and the RF modulation frequency is adjusted to be equal to one-half the hyperfine splitting, the absorption of the sidebands through the cell is slightly reduced due to the CPT effect. As the RF frequency is scanned over the resonance, lock-in detection is used to produce a /spl sim/1 kHz wide dispersive error signal which is in turn used to stabilize the modulation frequency. The narrow signal is the result of the buffer gas, which reduces the time-of-flight broadening of the transition.
We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.
We report a phase-sensitive microwave detection setup for spectroscopy of coherent population trapping (CPT) resonance in a Cs vapor cell. In this scheme, the optically carried microwave interrogation signal that interacts with atoms is detected by a fast photodiode at the cell output and is then mixed with the local oscillator microwave signal itself. This detection scheme produces at the output of the microwave mixer a dispersive CPT signal that can be directly used for correction of the local oscillator frequency onto the atomic resonance. The evolution of the dispersive CPT resonance signal with the laser power is briefly reported. With this detection scheme, we demonstrate the operation of a CPT atomic clock with a short-term fractional frequency stability of 1 × 10 − 11 at 1 s, which is in good agreement with the slope of the frequency discriminator and the residual microwave phase noise of the setup.
The authors presented investigations on the application of CPT effect as alternative to the traditional optical microwave double resonance in small atomic clocks. An important factor which may limit the performances of CPT-based atomic clocks is the reduced signal contrast as compared to optical pumping. To overcome this limit, several excitation schemes have been proposed in the last years. Particularly, a significant enhancement of the CPT contrast can be obtained when co-propagating laser waves with parallel linear polarization (lin | | lin CPT) are resonant with the excited state Fe=l of alkali atoms.