Applied Physics Letters

Radio-frequency single-electron transistor: Toward the shot-noise limit

A. Aassime, David Gunnarsson, Kevin Bladh, Per Delsing, R. J. Schoelkopf

Published Dec 10, 2001• 87 citations
Publisher

Abstract

We have fabricated an aluminum single-electron transistor and characterized it at frequencies up to 10 MHz by measuring the reflected signal from a resonant tank in which the transistor is embedded. We measured the charge sensitivity of this radio-frequency single-electron transistor to be 3.2×10−6 e/Hz, which corresponds to the uncoupled energy sensitivity of 4.8 ℏ. Our measurements indicate that with further improvements, the radio-frequency single-electron transistor could reach the shot-noise limit estimated to be about 1 ℏ.

DOI
10.1063/1.1424477

Related papers

Single-electron transistor as a radio-frequency mixer

Robert G. Knobel, Christopher S. Yung, Andrew N. Cleland

We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.

Applied Physics Letters•Jul 15, 2002•56 citations

Mixing with the radio frequency single-electron transistor

Loren J. Swenson, Daniel R. Schmidt, J. S. Aldridge +2 more

By configuring a radio frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultimately this device is limited in center frequency by the RC time of the transistor’s center island, which for our device is ∼1.6GHz, close to the measured value. The measurement bandwidth is determined by the quality factor of the readout tank circuit.

arXiv:cond-mat/0501623•Applied Physics Letters•Apr 20, 2005•7 citations

Towards shot noise-limited detection of a Single-Electron Transistor

Benedetta Camarota

A Single-Electron Transistor (SET) is a highly sensitive charge amplifier based on the Coulomb blockade that can operate near the quantum limit: amplification can be accomplished with a back-action close to that required by the uncertainty principle. Its charge sensitivity is ultimately limited to about 1micre/sqrt(Hz) by the shot noise in the source-drain current. Despite the fact that such sensitivity has been approached by some, the shot-noise limit has yet to be reached for either the SET and its RF version, the RF-SET. A scheme is proposed and realized in this thesis for the shot noise-limited detection of a Single-Electron Transistor, based on a DC-SQUID impedance-matched with a DC-biased SET. SQUIDs can operate at the quantum limit, and a microstrip SQUID amplifier has already been demonstrated to operate at almost twice the quantum-limited noise temperature at about 500MHz by M. Muck and collaborators, with a sensitivity sufficient to resolve the SET shot noise. The device has been fabricated and characterized. A 50KOhm resistor has been used as a noise source at low temperature and the measured noise levels have been estimated. Moreover, the detection noise temperature of about 110mK was derived corresponding to a current sensitivity of about 8fA/sqrt(Hz) for the detection of a 100KOhm resistor.

•Jan 8, 2008•0 citations

Numerical analysis of radio-frequency single-electron transistor operation

Valentin Olegovich Turin, Alexander N. Korotkov

We have analyzed numerically the response and noise-limited charge sensitivity of a radio-frequency single-electron transistor (RF-SET) in a nonsuperconducting state using the orthodox theory. In particular, we have studied the performance dependence on the quality factor Q of the tank circuit for Q both below and above the value corresponding to the impedance matching between the coaxial cable and SET.

arXiv:cond-mat/0308218•Physical Review B•May 21, 2004•11 citations

An ultrasensitive radio-frequency single-electron transistor working up to 4.2 K

Henrik Brenning, Sergey G. Kafanov, T. Duty +2 more

We present the measurement of a radio-frequency single-electron transistor that displays a very high charge sensitivity of 1.9 μe∕Hz at 4.2 K. At 40 mK, the charge sensitivity is 0.9 and 1.0 μe∕Hz in the superconducting and normal state, respectively. The sensitivity was measured as a function of radio frequency amplitude at three different temperatures; 40 mK, 1.8, and 4.2 K.

arXiv:cond-mat/0602518•Journal of Applied Physics•Dec 1, 2006•77 citations

The Radio-Frequency Single-Electron Transistor (RF-SET): A Fast and Ultrasensitive Electrometer

R. J. Schoelkopf, Paula Wahlgren, A. A. Kozhevnikov +2 more

A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.

Science•May 22, 1998•770 citations
We have fabricated an aluminum single-electron transistor and characterized it at frequencies up to 10 MHz by measuring the reflected signal from a resonant tank in which the transistor is embedded. We measured the charge sensitivity of this radio-frequency single-electron transistor to be 3.2×10−6 e/Hz, which corresponds to the uncoupled energy sensitivity of 4.8 ℏ. Our measurements indicate that with further improvements, the radio-frequency single-electron transistor could reach the shot-noise limit estimated to be about 1 ℏ.
We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.
By configuring a radio frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultimately this device is limited in center frequency by the RC time of the transistor’s center island, which for our device is ∼1.6GHz, close to the measured value. The measurement bandwidth is determined by the quality factor of the readout tank circuit.
A Single-Electron Transistor (SET) is a highly sensitive charge amplifier based on the Coulomb blockade that can operate near the quantum limit: amplification can be accomplished with a back-action close to that required by the uncertainty principle. Its charge sensitivity is ultimately limited to about 1micre/sqrt(Hz) by the shot noise in the source-drain current. Despite the fact that such sensitivity has been approached by some, the shot-noise limit has yet to be reached for either the SET and its RF version, the RF-SET. A scheme is proposed and realized in this thesis for the shot noise-limited detection of a Single-Electron Transistor, based on a DC-SQUID impedance-matched with a DC-biased SET. SQUIDs can operate at the quantum limit, and a microstrip SQUID amplifier has already been demonstrated to operate at almost twice the quantum-limited noise temperature at about 500MHz by M. Muck and collaborators, with a sensitivity sufficient to resolve the SET shot noise. The device has been fabricated and characterized. A 50KOhm resistor has been used as a noise source at low temperature and the measured noise levels have been estimated. Moreover, the detection noise temperature of about 110mK was derived corresponding to a current sensitivity of about 8fA/sqrt(Hz) for the detection of a 100KOhm resistor.
A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.