Applied Physics Letters

Single-electron transistor as a radio-frequency mixer

Robert G. Knobel, Christopher S. Yung, Andrew N. Cleland

Published Jul 15, 2002• 56 citations
Publisher

Abstract

We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.

DOI
10.1063/1.1493221

Related papers

An ultrasensitive radio-frequency single-electron transistor working up to 4.2 K

Henrik Brenning, Sergey G. Kafanov, T. Duty +2 more

We present the measurement of a radio-frequency single-electron transistor that displays a very high charge sensitivity of 1.9 μe∕Hz at 4.2 K. At 40 mK, the charge sensitivity is 0.9 and 1.0 μe∕Hz in the superconducting and normal state, respectively. The sensitivity was measured as a function of radio frequency amplitude at three different temperatures; 40 mK, 1.8, and 4.2 K.

arXiv:cond-mat/0602518•Journal of Applied Physics•Dec 1, 2006•77 citations

Mixing with the radio frequency single-electron transistor

Loren J. Swenson, Daniel R. Schmidt, J. S. Aldridge +2 more

By configuring a radio frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultimately this device is limited in center frequency by the RC time of the transistor’s center island, which for our device is ∼1.6GHz, close to the measured value. The measurement bandwidth is determined by the quality factor of the readout tank circuit.

arXiv:cond-mat/0501623•Applied Physics Letters•Apr 20, 2005•7 citations

Radio-frequency single-electron transistor: Toward the shot-noise limit

A. Aassime, David Gunnarsson, Kevin Bladh +2 more

We have fabricated an aluminum single-electron transistor and characterized it at frequencies up to 10 MHz by measuring the reflected signal from a resonant tank in which the transistor is embedded. We measured the charge sensitivity of this radio-frequency single-electron transistor to be 3.2×10−6 e/Hz, which corresponds to the uncoupled energy sensitivity of 4.8 ℏ. Our measurements indicate that with further improvements, the radio-frequency single-electron transistor could reach the shot-noise limit estimated to be about 1 ℏ.

Applied Physics Letters•Dec 10, 2001•87 citations

The Radio-Frequency Single-Electron Transistor (RF-SET): A Fast and Ultrasensitive Electrometer

R. J. Schoelkopf, Paula Wahlgren, A. A. Kozhevnikov +2 more

A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.

Science•May 22, 1998•770 citations

Inductive Single-Electron Transistor

Mika A. Sillanpää, Leif Roschier, Pertti Juhani Hakonen

We demonstrate a sensitive method of charge detection based on radio-frequency readout of the Josephson inductance of a superconducting single-electron transistor. Charge sensitivity 1.4 x 10(-4) e/square root Hz, limited by a preamplifier, is achieved in an operation mode which takes advantage of the nonlinearity of the Josephson potential. Owing to reactive readout, our setup has more than 2 orders of magnitude lower dissipation than the existing method of radio-frequency electrometry. With an optimized sample, we expect uncoupled energy sensitivity below variant Planck's over h in the same experimental scheme.

arXiv:cond-mat/0402045•Physical Review Letters•Aug 6, 2004•48 citations

Development and operation of the twin radio frequency single electron transistor for cross-correlated charge detection

Tilo M. Buehler, D. J. Reilly, R.P. Starrett +4 more

Ultrasensitive detectors and readout devices based on the radio frequency single electron transistor (rf-SET) combine near quantum-limited sensitivity with fast operation. Here we describe a twin rf-SET detector that uses two superconducting rf-SETs to perform fast, real-time cross-correlated measurements in order to distinguish subelectron signals from charge noise on microsecond time scales. The twin rf-SET makes use of two tuned resonance circuits to simultaneously and independently address both rf-SETs using wavelength division multiplexing and a single cryogenic amplifier. We focus on the operation of the twin rf-SET as a charge detector and evaluate the cross talk between the two resonance circuits. Real-time suppression of charge noise is demonstrated by cross correlating the signals from the two rf-SETs. For the case of simultaneous operation, the rf-SETs had charge sensitivities of δqSET1=7.5μe∕Hz and δqSET2=4.4μe∕Hz.

arXiv:cond-mat/0302085•Journal of Applied Physics•Oct 4, 2004•27 citations
We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.
By configuring a radio frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultimately this device is limited in center frequency by the RC time of the transistor’s center island, which for our device is ∼1.6GHz, close to the measured value. The measurement bandwidth is determined by the quality factor of the readout tank circuit.
We have fabricated an aluminum single-electron transistor and characterized it at frequencies up to 10 MHz by measuring the reflected signal from a resonant tank in which the transistor is embedded. We measured the charge sensitivity of this radio-frequency single-electron transistor to be 3.2×10−6 e/Hz, which corresponds to the uncoupled energy sensitivity of 4.8 ℏ. Our measurements indicate that with further improvements, the radio-frequency single-electron transistor could reach the shot-noise limit estimated to be about 1 ℏ.
A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.
We demonstrate a sensitive method of charge detection based on radio-frequency readout of the Josephson inductance of a superconducting single-electron transistor. Charge sensitivity 1.4 x 10(-4) e/square root Hz, limited by a preamplifier, is achieved in an operation mode which takes advantage of the nonlinearity of the Josephson potential. Owing to reactive readout, our setup has more than 2 orders of magnitude lower dissipation than the existing method of radio-frequency electrometry. With an optimized sample, we expect uncoupled energy sensitivity below variant Planck's over h in the same experimental scheme.
Ultrasensitive detectors and readout devices based on the radio frequency single electron transistor (rf-SET) combine near quantum-limited sensitivity with fast operation. Here we describe a twin rf-SET detector that uses two superconducting rf-SETs to perform fast, real-time cross-correlated measurements in order to distinguish subelectron signals from charge noise on microsecond time scales. The twin rf-SET makes use of two tuned resonance circuits to simultaneously and independently address both rf-SETs using wavelength division multiplexing and a single cryogenic amplifier. We focus on the operation of the twin rf-SET as a charge detector and evaluate the cross talk between the two resonance circuits. Real-time suppression of charge noise is demonstrated by cross correlating the signals from the two rf-SETs. For the case of simultaneous operation, the rf-SETs had charge sensitivities of δqSET1=7.5μe∕Hz and δqSET2=4.4μe∕Hz.