An rf wave applied to an optically pumped Na vapor in a high-density He+N2 buffer gas, situated in a magnetic field gradient, can produce localized bright fringes due to local rf magnetic resonance. We examine in this paper the features of optical pumping in a dense alkali-helium-nitrogen vapor mixture, and investigate how such systems can be optimized for use as a simple real-time rf spectrum analyzer (for broadcast rf waves) with a wide frequency range (dc to several GHz). We derive the optimum values of the optical pumping rate, helium density, sodium density, and nitrogen density which are necessary in order to produce sharp, high-contrast, and bright fringes, and have accurate and unambiguous rf frequency spectra determinations with fast dynamic response. Samples of observed rf frequency spectra are presented, and the observed spectrum of a sinusoidal FM wave compares satisfactorily with the theoretical spectrum. The observed rf resolution bandwidth is about equal to the optical pumping rate, which is about 1 kHz in this study (rf frequency ∼1 MHz). Similar resolution can be obtained in the microwave range.
An rf wave applied to an optically pumped Na vapor in a high-density He+N2 buffer gas, situated in a magnetic field gradient, can produce localized bright fringes due to local rf magnetic resonance. We examine in this paper the features of optical pumping in a dense alkali-helium-nitrogen vapor mixture, and investigate how such systems can be optimized for use as a simple real-time rf spectrum analyzer (for broadcast rf waves) with a wide frequency range (dc to several GHz). We derive the optimum values of the optical pumping rate, helium density, sodium density, and nitrogen density which are necessary in order to produce sharp, high-contrast, and bright fringes, and have accurate and unambiguous rf frequency spectra determinations with fast dynamic response. Samples of observed rf frequency spectra are presented, and the observed spectrum of a sinusoidal FM wave compares satisfactorily with the theoretical spectrum. The observed rf resolution bandwidth is about equal to the optical pumping rate, which is about 1 kHz in this study (rf frequency ∼1 MHz). Similar resolution can be obtained in the microwave range.
We report on broad instantaneous bandwidth microwave spectrum analysis with hot Rb 87 atoms in a microfabricated vapor cell in a large magnetic field gradient. The sensor is a MEMS atomic vapor cell filled with isotopically pure Rb 87 and N 2 buffer gas to localize the motion of the atoms. The microwave signals of interest are coupled through a coplanar waveguide to the cell, inducing spin-flip transitions between optically pumped ground states of the atoms. A static magnetic field with large gradient maps the frequency spectrum of the input microwave signals to a position-dependent spin-flip pattern on absorption images of the cell recorded with a laser beam onto a camera. In our proof-of-principle experiment, we demonstrate a microwave spectrum analyzer that has ≈ 1 GHz instantaneous bandwidth centered around 13 GHz, 3 MHz frequency resolution, 2 kHz refresh rate, and a − 23 dBm single-tone microwave power detection limit in 1 s measurement time. A theoretical model is constructed to simulate the image signals by considering the processes of optical pumping, microwave interaction, diffusion of Rb 87 atoms, and laser absorption. We expect to reach more than 25 GHz instantaneous bandwidth in an optimized setup, limited by the applied magnetic field gradient. Our demonstration offers a practical alternative to conventional microwave spectrum analyzers based on electronic heterodyne detection. Published by the American Physical Society 2024
III-8.Comparison of optical pumping signals for two spherical cells with different buffer gas pressures as a function of density times diameter of cell for equal D2/D1.60 IV-1.Energy level diagram showing hyperfine structure of Rb Di line.Units are 10*3 cm-1.67 IV-2.Equivalent circuit for rate equations involving ex change polarization.73 IV-3.Diagram of optical system for optical pumping of Rb. 83 IV-4.Block diagram of Rb optical pumping signal detection system.85 IV-5.Block diagram of Rb light detection system.90 IV-6.Typical photograph from which relaxation time measure ments are made..Time increases from left to right.Scale is 1 millisecond per division.92 IV-7.Lines determined from measurements on time dependence of Rb87 signals at 50°C for the two different light in tensities.Scatter of points is too small to be notice able on graph.93 A-1.Spectral profile of D1 radiation from a Varian spectral lamp containing natural Rb.Ill A-2.Spectral profile of Di radiation from a Varian spectral lamp containing Rb87.112 A-3-Spectral profile of Di radiation from a Varian spectral lamp containing Rb87 after filtering by an Rb85 absorption cell.113 vi CHAPTER I2 atomic ground states and the parameters of various relaxation processes of gaseous systems.These investigations led to the development of mag netometers of unique sensitivity.More recently, very precise frequency standards have been developed using the methods of optical pumping and the knowledge gained through their application.The present work was undertaken in the context of extending our knowledge of the dynamics of optical pumping methods and of exploiting these methods for the deter mination of an interesting atomic exchange cross section.Optical pumping may be considered as a specialized technique used in conjunction with magnetic resonance phenomena.All magnetic reso nance techniques depend upon obtaining an oriented (polarized) macro scopic sample of matter, that is, matter with a net magnetic moment.In the atomic beam magnetic resonance method, this is accomplished by sort ing out, spatially, atoms whose magnetic moments have a particular ori entation with respect to a magnetic field.In nuclear or electron para magnetic resonance work in solids, liquids, or gases, the small thermal equilibrium polarization that matter possesses in a magnetic field is exploited.Optical pumping enhances this equilibrium polarization through selective optical absorption, by a gaseous atomic system, of polarized resonance radiation.Optical pumping offers the great advan tage of experimental simplicity, as compared to other magnetic resonance techniques, but suffers from severe limitations in application.Since the original suggestion by Brossel and Nastier^ and subse quent development by many others, optical pumping, in conjunction with the transmission monitoring technique of signal detection, has became a standard technique in the study of alkali metal ground states.By far the greatest amount of work in optical pumping has been concerned with alkali metal vapors.Bell, Bloom/ and others^ have considered the process of the optical pumping of the alkalis with attention to the spec tral composition of the pumping light, that is, the resonance radiation incident on the alkali vapor.Colegrove and Franken? have recently dis cussed the complication in the analyses of optical pumping signals for Q helium when the helium absorption cell is optically thick.Hobart has considered this same complication for sodium.Prediction of signals must take into account the fact that the pumping light is absorbed ap proximately exponentially in the optical pumping absorption cell.This means that the absorption coefficient, which is proportional to the al kali density, times the length of the cell is a significant parameter in determining the strength of the signal.Similar calculations of the dependence of optical pumping signals on alkali density and spectral com position of the pumping light will be presented in this work.In order to test the signal predictions> a high resolution Fabry-Perot spectrometer was constructed.This instrument can be used for two purposes : the investigation of the intensity distribution of the pumping light, and, more importantly, determinations of the alkali vapor density in the absorption cell.The desired data are curves of optical pumping signals, for a typical sodium optical pumping experiment, as a function of density.It is often necessary to know these densities in order to is limited to the accuracy to which the density is known.Since the Fabry-Perot spectrometer used to measure sodium vapor densities in conjunction with the signal strength versus density meas urements can be applied to different systems, it was decided to make a determination of the rubidium 85-rubidium 87 spin exchange cross sec tion.The reasons for this choice are discussed in detail in Chapt.IV.In brief, work on rubidium exchange offered some experimental sim plifications and rubidium has previously been studied more thoroughly than other systems.
Abstract : A method for the optical observation of nutational resonance in optically pumped rubidium vapor has been studied both experimentally and theoretically. The method consists of pulsemodulating an rf magnetic field a one of the Zeeman resonance frequencies of the vapor and observing the resulting damped transient modulation in the transmitted light intensity. Of particular interest is the application of this method to a study of the spin relaxation of vapor atoms as influenced by the physical parameters of the system, in the case where the applied steady magnetic field is intense enough to cause individual Zeeman intervals to become noticeably unequal. Both single and double quantum resonances at a wide spectrum of Zeeman transitions of Rb-85 vapor diffusing through neon and helium buffer gases have been observed and identified, and the damping of the transient nutations in light intensity has been recorded under a variety of conditions. (Author)
A mixture of dense sodium vapor (number density [Na] \ensuremath{\sim} 1013 ${\mathrm{cm}}^{\ensuremath{-}3}$), and buffer gases helium, xenon, and nitrogen is optically pumped to a high degree of spin polarization using a single-frequency single-mode tunable dye laser. The relaxation in the "dark" of the variables 〈Sz〉 and $〈\stackrel{\ensuremath{\rightarrow}}{I}\ifmmode\cdot\else\textperiodcentered\fi{}\stackrel{\ensuremath{\rightarrow}}{S}〉$ is studied as a function of [Na] and buffergas pressures. For lower helium pressures (46-torr helium and 2-torr Xe) the dominant contribution to the relaxation of 〈Sz〉 in the presence of Xe comes from the "sticking" three-body collisions with He acting as the third body. This is further confirmed by studying the longitudinal magnetic field dependence of the spin-relaxation rate. At higher helium pressures (He 700 torr, and Xe 2 torr) the relaxation of 〈Sz〉 in the presence of Xe is mainly due to the "sudden" binary collisions between the Na and Xe, and the relaxation rate of 〈Sz〉 is independent of the longitudinal magnetic field. Significant hyperfine pumping is achieved by proper tuning of the laser. The temperature dependence of the relaxation of $〈\stackrel{\ensuremath{\rightarrow}}{I}\ifmmode\cdot\else\textperiodcentered\fi{}\stackrel{\ensuremath{\rightarrow}}{S}〉$ and 〈Sz〉 is also discussed.
We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.
When sodium vapor is irradiated with a single-frequency dye laser (pump) tuned in the vicinity of either of the Doppler-broadened D lines and enclosed in an optical cavity, Raman shifted oscillation builds up, which is blue shifted for a blue-detuned pump and red shifted for a red-detuned pump by 1.772 GHz (sodium ground-state hyperfine splitting).1 The gain mechanism responsible for this Raman-laser action can be understood by modeling sodium as a three-level atom. The Raman laser frequency is highly correlated with that of the pump as demonstrated earlier by observing a beat frequency bandwidth between the two lasers of as low as 17 kHz.2 (The pump had rms frequency fluctuation of the order of 10 MHz.) For spectroscopic applications, for example, frequency correlated laser beams are commonly generated using acoustooptic techniques which are difficult to implement beyond the gigahertz region. The Raman laser technique is extendable, in principle, even to the millimeter range. Here we present measurements of the sodium-density and pump-intensity dependence of the Raman-laser output and compare the results with those predicted by the three-level-atom model.