Wide bandwidth instantaneous radio frequency spectrum analyzer based on nitrogen vacancy centers in diamond

Mayeul Chipaux, Loïc Toraille, C. Larat, Loïc Morvan, Sébastien Pezzagna, J. Meijer, Thierry Debuisschert

Published Dec 7, 2015• 60 citations
arXivHTMLPDF

Abstract

We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.

DOI
10.1063/1.4936758

Related papers

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•1 citation

Spectral analysis of amplitude-modulated microwave signals with nitrogen-vacancy centers in diamond

Yang Zhitao, Feifei Zhou, Jianghang Yu +4 more

Microwave (MW) magnetometry utilizing nitrogen-vacancy (NV) centers in diamond offers a broad, tunable detection bandwidth enabled by the magnetic-field-dependent electron spin resonances (ESR) of the NV centers. In this work, we present and experimentally demonstrate two NV-based protocols for spectral analysis of amplitude-modulated (MW) signals. The first protocol employs the NV center as a bandpass filter and reconstructs frequency-domain information of MW signals by sweeping the MW carrier frequency. The second protocol achieves optical imaging of the MW spectrum using an NV-based quantum spectrum analyzer, wherein a magnetic field gradient spatially maps the ESR frequencies of the NV centers, enabling parallel detection of multiple spectral components over a wide instantaneous bandwidth. Both protocols show results that agree well with reference measurements from a classical spectrum analyzer. Our approaches extend the application of spin-based quantum sensors to the field of modern communications and can be adapted for other spin-based quantum sensors.

Review of Scientific Instruments•Feb 1, 2026•1 citation

A compact radiofrequency spectrum analyzer based on nitrogen-vacancy centers in diamond

Ludovic Mayer, Simone Magaletti, Ovidiu Brinza +4 more

We have realized a compact radiofrequency spectrum analyzer based on nitrogen-vacancy (NV) color centers in diamond. The RF spectral components are spatially encoded by means of a Zeeman shift of the NV resonances induced by a magnetic field gradient. The fluorescence of the NV centers is imaged on a CMOS detector array using a gradient index lens. The spectral components of the signal are revealed by the appearance of dark lines in the image. We observed frequencies up to 10 GHz, with a resolution of a few MHz and a RF sensitivity of the order of 100 µW.

Quantum Sensing and Nano Electronics and Photonics•Mar 15, 2023•0 citations

Simultaneous Identification of Multiple Microwave Signals in 313-MHz Continuous Bandwidth Using Nitrogen-Vacancy Centers in Diamond

Y. W. Jin, Huan Fei Wen, Ding Wang +8 more

The efficient and reliable detection of microwave signals is a key element of the breakthrough in new-generation communication technology. In this article, we proposed an approach for the simultaneous identification of multiple microwave signals in a continuous frequency range based on the spectral hole-burning effect of nitrogen-vacancy (NV) centers. The protocol combines the quantum wide-field imaging method with magnetic gradient means, breaking the narrowband and discrete detection limitations of conventional optically detected magnetic resonance (ODMR) techniques. The frequencies of multiple microwave signals can be accurately decoupled by locating the relevant gaps on resonance frequency curves. Meanwhile, the effects induced by fixed-frequency signals with different powers on the resonance frequency curves were systematically analyzed. The experimental results indicated that the system realized a multiple-frequency resolution of 1 MHz and a minimum detectable power of 1 mW over a continuous bandwidth of 313-MHz. This proposal is capable of real-time and simultaneous detection of multiple microwave signals, which remarkably improves the utilization efficiency of spectrum resources.

IEEE Transactions on Microwave Theory and Techniques•Jul 30, 2024•0 citations

A quantum radio frequency signal analyzer based on nitrogen vacancy centers in diamond

Simone Magaletti, Ludovic Mayer, Jean-François Roch +1 more

Abstract The rapid development of radio-frequency (RF) technologies requires tools which can efficiently monitor the electromagnetic landscape. Broadband real-time RF spectral analyzers need to operate at room temperature, with low power consumption and have a compact design for on-board device integration. Here we describe a Quantum Diamond Signal Analyzer (Q-DiSA) which detects RF signals over a tunable frequency range of 25 GHz with frequency resolution down to 1 MHz, a millisecond temporal resolution and a large dynamic range (40 dB). This approach exploits the room temperature spin properties of an ensemble of nitrogen-vacancy (NV) centers in diamond. Performance is enabled via our analyzer architecture which combines a specific diamond crystallographic cut with a simplified magnetic arrangement. This allows us to maintain the alignment of the magnetic field along the nitrogen-vacancy center axis whilst frequency tuning. These results demonstrate the potential of the Q-DiSA method for real-time broadband spectral analysis.

arXiv:2206.06734•Communications Engineering•Jul 27, 2022•47 citations

Imaging Frequency-Modulated Microwaves Using a Robust Quantum Spectrum Analyzer

Feifei Zhou, Yang Zhitao, Jae Su Yu +6 more

Spin-based quantum sensors have been applied to the quantum sensing of magnetic fields from DC to GHz with various schemes. The recently developed quantum spectrum analyzer (QSA) technique based on the nitrogen-vacancy (NV) centers in diamond shows an ultrawide frequency bandwidth in this application. Here, we improve this technique and develop a robust QSA via diamond engineering. This QSA exploits the electron spin resonance of NV centers in an engineered {111} industrial diamond, which cancels the complex process of magnetic arrangement and significantly enhances the robustness of QSA against spin mixing under high magnetic fields in practice. A tunable frequency bandwidth of up to 18 GHz with a maximum instantaneous bandwidth of 2 GHz is achieved as well as a frequency resolution of several MHz and a large dynamic range of 65 dB. Using this QSA, we realize the optical imaging of frequency-modulated microwaves. Our work provides a promising rapid-deployment architecture for QSA and extends its application to spectral analysis in modern communications.

ACS Photonics•Nov 26, 2025•1 citation
We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
Microwave (MW) magnetometry utilizing nitrogen-vacancy (NV) centers in diamond offers a broad, tunable detection bandwidth enabled by the magnetic-field-dependent electron spin resonances (ESR) of the NV centers. In this work, we present and experimentally demonstrate two NV-based protocols for spectral analysis of amplitude-modulated (MW) signals. The first protocol employs the NV center as a bandpass filter and reconstructs frequency-domain information of MW signals by sweeping the MW carrier frequency. The second protocol achieves optical imaging of the MW spectrum using an NV-based quantum spectrum analyzer, wherein a magnetic field gradient spatially maps the ESR frequencies of the NV centers, enabling parallel detection of multiple spectral components over a wide instantaneous bandwidth. Both protocols show results that agree well with reference measurements from a classical spectrum analyzer. Our approaches extend the application of spin-based quantum sensors to the field of modern communications and can be adapted for other spin-based quantum sensors.
We have realized a compact radiofrequency spectrum analyzer based on nitrogen-vacancy (NV) color centers in diamond. The RF spectral components are spatially encoded by means of a Zeeman shift of the NV resonances induced by a magnetic field gradient. The fluorescence of the NV centers is imaged on a CMOS detector array using a gradient index lens. The spectral components of the signal are revealed by the appearance of dark lines in the image. We observed frequencies up to 10 GHz, with a resolution of a few MHz and a RF sensitivity of the order of 100 µW.
The efficient and reliable detection of microwave signals is a key element of the breakthrough in new-generation communication technology. In this article, we proposed an approach for the simultaneous identification of multiple microwave signals in a continuous frequency range based on the spectral hole-burning effect of nitrogen-vacancy (NV) centers. The protocol combines the quantum wide-field imaging method with magnetic gradient means, breaking the narrowband and discrete detection limitations of conventional optically detected magnetic resonance (ODMR) techniques. The frequencies of multiple microwave signals can be accurately decoupled by locating the relevant gaps on resonance frequency curves. Meanwhile, the effects induced by fixed-frequency signals with different powers on the resonance frequency curves were systematically analyzed. The experimental results indicated that the system realized a multiple-frequency resolution of 1 MHz and a minimum detectable power of 1 mW over a continuous bandwidth of 313-MHz. This proposal is capable of real-time and simultaneous detection of multiple microwave signals, which remarkably improves the utilization efficiency of spectrum resources.
Abstract The rapid development of radio-frequency (RF) technologies requires tools which can efficiently monitor the electromagnetic landscape. Broadband real-time RF spectral analyzers need to operate at room temperature, with low power consumption and have a compact design for on-board device integration. Here we describe a Quantum Diamond Signal Analyzer (Q-DiSA) which detects RF signals over a tunable frequency range of 25 GHz with frequency resolution down to 1 MHz, a millisecond temporal resolution and a large dynamic range (40 dB). This approach exploits the room temperature spin properties of an ensemble of nitrogen-vacancy (NV) centers in diamond. Performance is enabled via our analyzer architecture which combines a specific diamond crystallographic cut with a simplified magnetic arrangement. This allows us to maintain the alignment of the magnetic field along the nitrogen-vacancy center axis whilst frequency tuning. These results demonstrate the potential of the Q-DiSA method for real-time broadband spectral analysis.
Spin-based quantum sensors have been applied to the quantum sensing of magnetic fields from DC to GHz with various schemes. The recently developed quantum spectrum analyzer (QSA) technique based on the nitrogen-vacancy (NV) centers in diamond shows an ultrawide frequency bandwidth in this application. Here, we improve this technique and develop a robust QSA via diamond engineering. This QSA exploits the electron spin resonance of NV centers in an engineered {111} industrial diamond, which cancels the complex process of magnetic arrangement and significantly enhances the robustness of QSA against spin mixing under high magnetic fields in practice. A tunable frequency bandwidth of up to 18 GHz with a maximum instantaneous bandwidth of 2 GHz is achieved as well as a frequency resolution of several MHz and a large dynamic range of 65 dB. Using this QSA, we realize the optical imaging of frequency-modulated microwaves. Our work provides a promising rapid-deployment architecture for QSA and extends its application to spectral analysis in modern communications.