An Interferometric Technique Of Density Measurement Applied To Alkali-metal Vapors Oriented By Optical Pumping.
Steven Jarrett
Abstract
III-8.Comparison of optical pumping signals for two spherical cells with different buffer gas pressures as a function of density times diameter of cell for equal D2/D1.60 IV-1.Energy level diagram showing hyperfine structure of Rb Di line.Units are 10*3 cm-1.67 IV-2.Equivalent circuit for rate equations involving ex change polarization.73 IV-3.Diagram of optical system for optical pumping of Rb. 83 IV-4.Block diagram of Rb optical pumping signal detection system.85 IV-5.Block diagram of Rb light detection system.90 IV-6.Typical photograph from which relaxation time measure ments are made..Time increases from left to right.Scale is 1 millisecond per division.92 IV-7.Lines determined from measurements on time dependence of Rb87 signals at 50°C for the two different light in tensities.Scatter of points is too small to be notice able on graph.93 A-1.Spectral profile of D1 radiation from a Varian spectral lamp containing natural Rb.Ill A-2.Spectral profile of Di radiation from a Varian spectral lamp containing Rb87.112 A-3-Spectral profile of Di radiation from a Varian spectral lamp containing Rb87 after filtering by an Rb85 absorption cell.113 vi CHAPTER I2 atomic ground states and the parameters of various relaxation processes of gaseous systems.These investigations led to the development of mag netometers of unique sensitivity.More recently, very precise frequency standards have been developed using the methods of optical pumping and the knowledge gained through their application.The present work was undertaken in the context of extending our knowledge of the dynamics of optical pumping methods and of exploiting these methods for the deter mination of an interesting atomic exchange cross section.Optical pumping may be considered as a specialized technique used in conjunction with magnetic resonance phenomena.All magnetic reso nance techniques depend upon obtaining an oriented (polarized) macro scopic sample of matter, that is, matter with a net magnetic moment.In the atomic beam magnetic resonance method, this is accomplished by sort ing out, spatially, atoms whose magnetic moments have a particular ori entation with respect to a magnetic field.In nuclear or electron para magnetic resonance work in solids, liquids, or gases, the small thermal equilibrium polarization that matter possesses in a magnetic field is exploited.Optical pumping enhances this equilibrium polarization through selective optical absorption, by a gaseous atomic system, of polarized resonance radiation.Optical pumping offers the great advan tage of experimental simplicity, as compared to other magnetic resonance techniques, but suffers from severe limitations in application.Since the original suggestion by Brossel and Nastier^ and subse quent development by many others, optical pumping, in conjunction with the transmission monitoring technique of signal detection, has became a standard technique in the study of alkali metal ground states.By far the greatest amount of work in optical pumping has been concerned with alkali metal vapors.Bell, Bloom/ and others^ have considered the process of the optical pumping of the alkalis with attention to the spec tral composition of the pumping light, that is, the resonance radiation incident on the alkali vapor.Colegrove and Franken? have recently dis cussed the complication in the analyses of optical pumping signals for Q helium when the helium absorption cell is optically thick.Hobart has considered this same complication for sodium.Prediction of signals must take into account the fact that the pumping light is absorbed ap proximately exponentially in the optical pumping absorption cell.This means that the absorption coefficient, which is proportional to the al kali density, times the length of the cell is a significant parameter in determining the strength of the signal.Similar calculations of the dependence of optical pumping signals on alkali density and spectral com position of the pumping light will be presented in this work.In order to test the signal predictions> a high resolution Fabry-Perot spectrometer was constructed.This instrument can be used for two purposes : the investigation of the intensity distribution of the pumping light, and, more importantly, determinations of the alkali vapor density in the absorption cell.The desired data are curves of optical pumping signals, for a typical sodium optical pumping experiment, as a function of density.It is often necessary to know these densities in order to is limited to the accuracy to which the density is known.Since the Fabry-Perot spectrometer used to measure sodium vapor densities in conjunction with the signal strength versus density meas urements can be applied to different systems, it was decided to make a determination of the rubidium 85-rubidium 87 spin exchange cross sec tion.The reasons for this choice are discussed in detail in Chapt.IV.In brief, work on rubidium exchange offered some experimental sim plifications and rubidium has previously been studied more thoroughly than other systems.