Physical Review A

Subkilohertz absolute-frequency measurement of the 467-nm electric octupole transition in 171Yb+

P. J. Blythe, Stephen A. Webster, Helen S. Margolis, S.N. Lea, Guozheng Huang, Sang-Kyung Choi, W. R. C. Rowley, Patrick Robert Gill, Robert S. Windeler

Published Feb 10, 2003• 39 citations
Publisher

Abstract

The ${}^{2}{S}_{1/2}{(F=0)}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ transition at 467 nm in a single trapped, laser-cooled ion of ${}^{171}{\mathrm{Yb}}^{+}$ has been measured to be ${f}_{{\mathrm{Yb}}^{+}}=642121496771.26(23)\mathrm{kHz}$ using a femtosecond laser frequency comb generator. The measurement is limited by measurement statistics and by the ac Stark shift, both related to the 4.5 kHz linewidth of the probe laser at the time. The systematic shifts of the transition, including ac Stark, second-order Zeeman, quadrupole, and blackbody shifts, have been evaluated.

DOI
10.1103/physreva.67.020501

Related papers

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Kilohertz-resolution spectroscopy of the 2S1/2−2F7/2 electric octupole transition in a single 171Yb+ ion

Stephen A. Webster, Philip H. Taylor, M. Roberts +2 more

Spectroscopy has been performed on $\mathrm{the}{}^{2}{S}_{1/2}(F=0,{m}_{F}{=0)\ensuremath{-}}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ electric octupole transition in ${}^{171}{\mathrm{Yb}}^{+}$ with kilohertz resolution. A quantum jump rate of more than one per second has been achieved, a factor of 100 improvement on previous work. Spectra including the sidebands at the trap secular frequency show the ion to be in the Lambe-Dicke regime and hence the Doppler effect has been eliminated to first order. The dynamic Stark shift is a significant perturbation to the frequency because of the high intensity required to drive the octupole transition. It has been measured as ${42}_{\ensuremath{-}10}^{+12} \ensuremath{\mu}\mathrm{Hz}{\mathrm{W}}^{\ensuremath{-}1}{\mathrm{m}}^{2}$ and with further reduction in the probe laser linewidth, it should be possible to reduce the relative uncertainty in this shift to the parts in ${10}^{18}$ level. The transition is free from the Zeeman effect to first order and has a measured second-order shift of $1.9(3) \mathrm{mHz}(\ensuremath{\mu}\mathrm{T}{)}^{\ensuremath{-}2}.$ It should be possible to reduce the relative uncertainty in this shift to below the part in ${10}^{18}$ level. The electric quadrupole shift may be the limiting systematic effect, but cannot yet be observed with the current resolution on the transition.

Physical Review A•Apr 15, 2002•33 citations

Frequency measurement of the S21/2−F27/2 electric octupole transition in a single Y171b+ ion

Kazumoto Hosaka, Stephen A. Webster, A. F. B. Stannard +3 more

We report on precision laser spectroscopy of the ${^{2}S}_{1/2}(F=0)\text{\ensuremath{-}}{^{2}F}_{7/2}(F=3,{m}_{F}=0)$ clock transition in a single ion of ${^{171}\text{Y}\text{b}}^{+}$. A linewidth of $<40\text{ }\text{Hz}$ is observed and frequency instability due to fluctuation of the ac Stark shift is reduced through improved stability of the beam alignment. The absolute value of the transition frequency, determined using an optical frequency comb, is $642\text{ }121\text{ }496\text{ }772\text{ }657\ifmmode\pm\else\textpm\fi{}12\text{ }\text{Hz}$ with a fractional uncertainty of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$. This is a factor of 50 better than the previously published value [Hosaka et al., IEEE Trans. Instrum. Meas. 54, 759 (2005)].

Physical Review A•Mar 10, 2009•57 citations

An optical frequency standard based on the 2 S 1/2 — 2 F 7/2 transition in 171 Yb +

Stephen A. Webster, A. F. B. Stannard, Kazumoto Hosaka +1 more

The 2S1/2 (F = 0) - 2F7/2 (F = 3, m F = 0) transition at 467 nm in a single, trapped, laser cooled ion of 171Yb+ has the potential to be an extremely accurate optical frequency reference. Systematic shifts have been evaluated and are currently dominated by the ac-Stark shift. However, this is not expected to be the case as probe laser linewidth is reduced. A heterodyne measurement of the probe laser shows it to have a width of 20 Hz on a 1 minute timescale. The atomic spectrum on the other hand, has been found to have a broadened width of 200 Hz. Using heterodyne detection of light reflected from the trap electrodes, Doppler shifting due to vibration of the trap is identified as the additional source of broadening.

European Frequency and Time Forum•Jan 1, 2006•0 citations

SPECTROSCOPY AND PRECISION FREQUENCY MEASUREMENT OF THE 435.5 nm CLOCK TRANSITION OF 171 Yb +

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .

Symposium on Frequency Standards and Metrology•May 1, 2002•3 citations

High-Accuracy Optical Clock Based on the Octupole Transition in Yb+171

Nils Huntemann, Maksim V. Okhapkin, B. Lipphardt +3 more

We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.

arXiv:1111.2446•Physical Review Letters•Feb 29, 2012•252 citations
The 2S1/2(F=0)2F7/2(F=3,mF=0){}^{2}{S}_{1/2}{(F=0)}^{2}{F}_{7/2}{(F=3,m}_{F}=0)2S1/2​(F=0)2F7/2​(F=3,mF​=0) transition at 467 nm in a single trapped, laser-cooled ion of 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+ has been measured to be fYb+=642121496771.26(23)kHz{f}_{{\mathrm{Yb}}^{+}}=642121496771.26(23)\mathrm{kHz}fYb+​=642121496771.26(23)kHz using a femtosecond laser frequency comb generator. The measurement is limited by measurement statistics and by the ac Stark shift, both related to the 4.5 kHz linewidth of the probe laser at the time. The systematic shifts of the transition, including ac Stark, second-order Zeeman, quadrupole, and blackbody shifts, have been evaluated.
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.
Spectroscopy has been performed on $\mathrm{the}{}^{2}{S}_{1/2}(F=0,{m}_{F}{=0)\ensuremath{-}}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ electric octupole transition in 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+ with kilohertz resolution. A quantum jump rate of more than one per second has been achieved, a factor of 100 improvement on previous work. Spectra including the sidebands at the trap secular frequency show the ion to be in the Lambe-Dicke regime and hence the Doppler effect has been eliminated to first order. The dynamic Stark shift is a significant perturbation to the frequency because of the high intensity required to drive the octupole transition. It has been measured as ${42}_{\ensuremath{-}10}^{+12} \ensuremath{\mu}\mathrm{Hz}{\mathrm{W}}^{\ensuremath{-}1}{\mathrm{m}}^{2}$ and with further reduction in the probe laser linewidth, it should be possible to reduce the relative uncertainty in this shift to the parts in 1018{10}^{18}1018 level. The transition is free from the Zeeman effect to first order and has a measured second-order shift of $1.9(3) \mathrm{mHz}(\ensuremath{\mu}\mathrm{T}{)}^{\ensuremath{-}2}.$ It should be possible to reduce the relative uncertainty in this shift to below the part in 1018{10}^{18}1018 level. The electric quadrupole shift may be the limiting systematic effect, but cannot yet be observed with the current resolution on the transition.
We report on precision laser spectroscopy of the ${^{2}S}_{1/2}(F=0)\text{\ensuremath{-}}{^{2}F}_{7/2}(F=3,{m}_{F}=0)$ clock transition in a single ion of 171Yb+{^{171}\text{Y}\text{b}}^{+}171Yb+. A linewidth of <40 Hz<40\text{ }\text{Hz}<40 Hz is observed and frequency instability due to fluctuation of the ac Stark shift is reduced through improved stability of the beam alignment. The absolute value of the transition frequency, determined using an optical frequency comb, is $642\text{ }121\text{ }496\text{ }772\text{ }657\ifmmode\pm\else\textpm\fi{}12\text{ }\text{Hz}$ with a fractional uncertainty of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$. This is a factor of 50 better than the previously published value [Hosaka et al., IEEE Trans. Instrum. Meas. 54, 759 (2005)].
The 2S1/2 (F = 0) - 2F7/2 (F = 3, m F = 0) transition at 467 nm in a single, trapped, laser cooled ion of 171Yb+ has the potential to be an extremely accurate optical frequency reference. Systematic shifts have been evaluated and are currently dominated by the ac-Stark shift. However, this is not expected to be the case as probe laser linewidth is reduced. A heterodyne measurement of the probe laser shows it to have a width of 20 Hz on a 1 minute timescale. The atomic spectrum on the other hand, has been found to have a broadened width of 200 Hz. Using heterodyne detection of light reflected from the trap electrodes, Doppler shifting due to vibration of the trap is identified as the additional source of broadening.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.