Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1111.2446 · Physical Review Letters

High-Accuracy Optical Clock Based on the Octupole Transition in Yb+171

Nils Huntemann, Maksim V. Okhapkin, B. Lipphardt, S. Weyers, Chr. Tamm, E. Peik

Published Feb 29, 2012• 252 citations
arXivHTMLPDF

Abstract

We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.

DOI
10.1103/physrevlett.108.090801

Related papers

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

SPECTROSCOPY AND PRECISION FREQUENCY MEASUREMENT OF THE 435.5 nm CLOCK TRANSITION OF 171 Yb +

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .

Symposium on Frequency Standards and Metrology•May 1, 2002•3 citations

Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty

Nils Huntemann, Christian Sanner, B. Lipphardt +2 more

We experimentally investigate an optical frequency standard based on the (2)S1/2(F=0)→(2)F7/2(F=3) electric octupole (E3) transition of a single trapped (171)Yb+ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy, which reduces the related relative frequency uncertainty to 1.1×10(-18). To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the E3 transition as 0.888(16)×10(-40) J m(2)/V(2) and a dynamic correction η(300 K)=-0.0015(7). This reduces the uncertainty due to thermal radiation to 1.8×10(-18). The residual motion of the ion yields the largest contribution (2.1×10(-18)) to the total systematic relative uncertainty of the clock of 3.2×10(-18).

arXiv:1602.03908•Physical Review Letters•Feb 8, 2016•702 citations

Stray-field-induced quadrupole shift and absolute frequency of the 688-THz Y171b+ single-ion optical frequency standard

Chr. Tamm, S. Weyers, B. Lipphardt +1 more

We report experimental investigations of a single-ion optical frequency standard based on ${^{171}\text{Y}\text{b}}^{+}$. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the ${^{2}S}_{1/2}(F=0)--{^{2}D}_{3/2}({F}^{\ensuremath{'}}=2)$ electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the interaction of the electric quadrupole moment of the ${^{2}D}_{3/2}$ state with the gradient of the electrostatic stray field in the trap. We determine an upper limit for the instability of the quadrupole shift over times between 100 s to 20 h. We also observe the variations in the shift and in the applied stray-field compensation voltages that result from loading a new ion into the trap and during a subsequent storage period of 74 days. This information is utilized to measure the absolute frequency of the reference transition with an uncertainty that is a factor of 3 smaller than that of the previous measurement. Using a fiber laser based optical frequency comb generator and the cesium fountain clock CSF1 of PTB (Physikalisch-Technische Bundesanstalt), the frequency at 300 K temperature is determined as $688\text{ }358\text{ }979\text{ }309\text{ }306.62\ifmmode\pm\else\textpm\fi{}0.73\text{ }\text{Hz}$.

Physical Review A•Oct 6, 2009•103 citations

Progress toward a single ytterbium ion optical clock

Paul Taylor, Stephen A. Webster, Matthew Roberts +3 more

Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations

Yb+ single-ion optical frequency standard with systematic uncertainty at the 10−17 level

Nils Huntemann, B. Lipphardt, Maksim V. Okhapkin +2 more

The171Yb+ion possesses two transitions that are applicable as references for optical frequency standards and several general features make this ion attractive: All relevant radiations for cooling and excitation can be generated from diode lasers. A nuclear spin of 1/2 ensures a simple sublevel structure. Long storage times of Yb+in ion traps are easily obtained. The2S1/2(F = 0) →2D3/2(F = 2, mF= 0) electric quadrupole transition at 436 nm with a natural linewidth of 3.1 Hz provides a quantum noise limited instability of a single-ion frequency standard of about 2 × 10-15in 1 s. The electric octupole transition2S1/2(F = 0)→2F7/2(F = 3, mF= 0) at 467 nm with a natural linewidth in the nHz range will allow to surpass that instability level. It also possesses a lower sensitivity to field-induced frequency shifts. In this system the Fourier-limited interrogation linewidth can be adapted to that of the best available laser sources, which are presently at the level below 1 Hz. Both transitions have been recommended as secondary representations of the SI second.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2013•0 citations
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .
We experimentally investigate an optical frequency standard based on the (2)S1/2(F=0)→(2)F7/2(F=3) electric octupole (E3) transition of a single trapped (171)Yb+ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy, which reduces the related relative frequency uncertainty to 1.1×10(-18). To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the E3 transition as 0.888(16)×10(-40) J m(2)/V(2) and a dynamic correction η(300 K)=-0.0015(7). This reduces the uncertainty due to thermal radiation to 1.8×10(-18). The residual motion of the ion yields the largest contribution (2.1×10(-18)) to the total systematic relative uncertainty of the clock of 3.2×10(-18).
We report experimental investigations of a single-ion optical frequency standard based on 171Yb+{^{171}\text{Y}\text{b}}^{+}171Yb+. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the ${^{2}S}_{1/2}(F=0)--{^{2}D}_{3/2}({F}^{\ensuremath{'}}=2)$ electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the interaction of the electric quadrupole moment of the 2D3/2{^{2}D}_{3/2}2D3/2​ state with the gradient of the electrostatic stray field in the trap. We determine an upper limit for the instability of the quadrupole shift over times between 100 s to 20 h. We also observe the variations in the shift and in the applied stray-field compensation voltages that result from loading a new ion into the trap and during a subsequent storage period of 74 days. This information is utilized to measure the absolute frequency of the reference transition with an uncertainty that is a factor of 3 smaller than that of the previous measurement. Using a fiber laser based optical frequency comb generator and the cesium fountain clock CSF1 of PTB (Physikalisch-Technische Bundesanstalt), the frequency at 300 K temperature is determined as $688\text{ }358\text{ }979\text{ }309\text{ }306.62\ifmmode\pm\else\textpm\fi{}0.73\text{ }\text{Hz}$.
Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.
The171Yb+ion possesses two transitions that are applicable as references for optical frequency standards and several general features make this ion attractive: All relevant radiations for cooling and excitation can be generated from diode lasers. A nuclear spin of 1/2 ensures a simple sublevel structure. Long storage times of Yb+in ion traps are easily obtained. The2S1/2(F = 0) →2D3/2(F = 2, mF= 0) electric quadrupole transition at 436 nm with a natural linewidth of 3.1 Hz provides a quantum noise limited instability of a single-ion frequency standard of about 2 × 10-15in 1 s. The electric octupole transition2S1/2(F = 0)→2F7/2(F = 3, mF= 0) at 467 nm with a natural linewidth in the nHz range will allow to surpass that instability level. It also possesses a lower sensitivity to field-induced frequency shifts. In this system the Fourier-limited interrogation linewidth can be adapted to that of the best available laser sources, which are presently at the level below 1 Hz. Both transitions have been recommended as secondary representations of the SI second.