Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Frequency measurement of the S21/2−F27/2 electric octupole transition in a single Y171b+ ion

Kazumoto Hosaka, Stephen A. Webster, A. F. B. Stannard, B. R. Walton, Helen S. Margolis, Patrick Robert Gill

Published Mar 10, 2009• 57 citations
Publisher

Abstract

We report on precision laser spectroscopy of the ${^{2}S}_{1/2}(F=0)\text{\ensuremath{-}}{^{2}F}_{7/2}(F=3,{m}_{F}=0)$ clock transition in a single ion of ${^{171}\text{Y}\text{b}}^{+}$. A linewidth of $<40\text{ }\text{Hz}$ is observed and frequency instability due to fluctuation of the ac Stark shift is reduced through improved stability of the beam alignment. The absolute value of the transition frequency, determined using an optical frequency comb, is $642\text{ }121\text{ }496\text{ }772\text{ }657\ifmmode\pm\else\textpm\fi{}12\text{ }\text{Hz}$ with a fractional uncertainty of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$. This is a factor of 50 better than the previously published value [Hosaka et al., IEEE Trans. Instrum. Meas. 54, 759 (2005)].

DOI
10.1103/physreva.79.033403

Related papers

Subkilohertz absolute-frequency measurement of the 467-nm electric octupole transition in 171Yb+

P. J. Blythe, Stephen A. Webster, Helen S. Margolis +6 more

The ${}^{2}{S}_{1/2}{(F=0)}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ transition at 467 nm in a single trapped, laser-cooled ion of ${}^{171}{\mathrm{Yb}}^{+}$ has been measured to be ${f}_{{\mathrm{Yb}}^{+}}=642121496771.26(23)\mathrm{kHz}$ using a femtosecond laser frequency comb generator. The measurement is limited by measurement statistics and by the ac Stark shift, both related to the 4.5 kHz linewidth of the probe laser at the time. The systematic shifts of the transition, including ac Stark, second-order Zeeman, quadrupole, and blackbody shifts, have been evaluated.

Physical Review A•Feb 10, 2003•39 citations

Frequency measurement of the 2S1/2 – 2D3/2 electric quadrupole transition in a single 171Yb+ ion

Stephen A. Webster, R. M. Godun, S. A. King +6 more

We report on precision laser spectroscopy of the2S1/2(F = 0) -2D3/2(F = 2, mF= 0) clock transition in a single ion of171Yb+. The absolute value of the transition frequency, determined using an optical frequency comb referenced to a hydrogen maser, is 688 358 979 309 310 plusmn 9 Hz. This corresponds to a fractional uncertainty of 1.3 times 10-14.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•0 citations

Frequency measurement of the 2S1/2_2D3/2 electric quadrupole transition in a single 171yb+ ion

Stephen A. Webster, R. M. Godun, S. A. King +6 more

We report on precision laser spectroscopy of the 2S(1/2)(F = 0)-2D(3/2) (F = 2, m(F) = 0) clock transition in a single ion of 171Yb+. The absolute value of the transition frequency, determined using an optical frequency comb referenced to a hydrogen maser, is 688358979309310 +/- 9 Hz. This corresponds to a fractional frequency uncertainty of 1.3 x 10(-14).

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2010•19 citations

Kilohertz-resolution spectroscopy of the 2S1/2−2F7/2 electric octupole transition in a single 171Yb+ ion

Stephen A. Webster, Philip H. Taylor, M. Roberts +2 more

Spectroscopy has been performed on $\mathrm{the}{}^{2}{S}_{1/2}(F=0,{m}_{F}{=0)\ensuremath{-}}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ electric octupole transition in ${}^{171}{\mathrm{Yb}}^{+}$ with kilohertz resolution. A quantum jump rate of more than one per second has been achieved, a factor of 100 improvement on previous work. Spectra including the sidebands at the trap secular frequency show the ion to be in the Lambe-Dicke regime and hence the Doppler effect has been eliminated to first order. The dynamic Stark shift is a significant perturbation to the frequency because of the high intensity required to drive the octupole transition. It has been measured as ${42}_{\ensuremath{-}10}^{+12} \ensuremath{\mu}\mathrm{Hz}{\mathrm{W}}^{\ensuremath{-}1}{\mathrm{m}}^{2}$ and with further reduction in the probe laser linewidth, it should be possible to reduce the relative uncertainty in this shift to the parts in ${10}^{18}$ level. The transition is free from the Zeeman effect to first order and has a measured second-order shift of $1.9(3) \mathrm{mHz}(\ensuremath{\mu}\mathrm{T}{)}^{\ensuremath{-}2}.$ It should be possible to reduce the relative uncertainty in this shift to below the part in ${10}^{18}$ level. The electric quadrupole shift may be the limiting systematic effect, but cannot yet be observed with the current resolution on the transition.

Physical Review A•Apr 15, 2002•33 citations

Precision frequency measurement of the 2S1/2 — 2F7/2 electric octupole transition in a single 171Yb+ ion

Stephen A. Webster, Kazumoto Hosaka, Barney Walton +2 more

We report precision laser spectroscopy of the2S1/2(F = 0, mF=0)-2F7/2(F =3, mF= 0) clock transition in a single, trapped, laser cooled ion of171Yb+. The absolute frequency is measured to be 642 121 496 772 656 (12) Hz, a factor of 20 more accurate than previous measurements.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•5 citations

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations
We report on precision laser spectroscopy of the 2S1/2(F=0)\ensuremath-2F7/2(F=3,mF=0){^{2}S}_{1/2}(F=0)\text{\ensuremath{-}}{^{2}F}_{7/2}(F=3,{m}_{F}=0)2S1/2​(F=0)\ensuremath-2F7/2​(F=3,mF​=0) clock transition in a single ion of 171Yb+{^{171}\text{Y}\text{b}}^{+}171Yb+. A linewidth of <40 Hz<40\text{ }\text{Hz}<40 Hz is observed and frequency instability due to fluctuation of the ac Stark shift is reduced through improved stability of the beam alignment. The absolute value of the transition frequency, determined using an optical frequency comb, is 642 121 496 772 657\ifmmode±\else\textpm\fi12 Hz642\text{ }121\text{ }496\text{ }772\text{ }657\ifmmode\pm\else\textpm\fi{}12\text{ }\text{Hz}642 121 496 772 657\ifmmode±\else\textpm\fi12 Hz with a fractional uncertainty of 2\ifmmode×\else\texttimes\fi10\ensuremath−142\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}2\ifmmode×\else\texttimes\fi10\ensuremath−14. This is a factor of 50 better than the previously published value [Hosaka et al., IEEE Trans. Instrum. Meas. 54, 759 (2005)].
The 2S1/2(F=0)2F7/2(F=3,mF=0){}^{2}{S}_{1/2}{(F=0)}^{2}{F}_{7/2}{(F=3,m}_{F}=0)2S1/2​(F=0)2F7/2​(F=3,mF​=0) transition at 467 nm in a single trapped, laser-cooled ion of 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+ has been measured to be fYb+=642121496771.26(23)kHz{f}_{{\mathrm{Yb}}^{+}}=642121496771.26(23)\mathrm{kHz}fYb+​=642121496771.26(23)kHz using a femtosecond laser frequency comb generator. The measurement is limited by measurement statistics and by the ac Stark shift, both related to the 4.5 kHz linewidth of the probe laser at the time. The systematic shifts of the transition, including ac Stark, second-order Zeeman, quadrupole, and blackbody shifts, have been evaluated.
Spectroscopy has been performed on $\mathrm{the}{}^{2}{S}_{1/2}(F=0,{m}_{F}{=0)\ensuremath{-}}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ electric octupole transition in 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+ with kilohertz resolution. A quantum jump rate of more than one per second has been achieved, a factor of 100 improvement on previous work. Spectra including the sidebands at the trap secular frequency show the ion to be in the Lambe-Dicke regime and hence the Doppler effect has been eliminated to first order. The dynamic Stark shift is a significant perturbation to the frequency because of the high intensity required to drive the octupole transition. It has been measured as ${42}_{\ensuremath{-}10}^{+12} \ensuremath{\mu}\mathrm{Hz}{\mathrm{W}}^{\ensuremath{-}1}{\mathrm{m}}^{2}$ and with further reduction in the probe laser linewidth, it should be possible to reduce the relative uncertainty in this shift to the parts in 1018{10}^{18}1018 level. The transition is free from the Zeeman effect to first order and has a measured second-order shift of $1.9(3) \mathrm{mHz}(\ensuremath{\mu}\mathrm{T}{)}^{\ensuremath{-}2}.$ It should be possible to reduce the relative uncertainty in this shift to below the part in 1018{10}^{18}1018 level. The electric quadrupole shift may be the limiting systematic effect, but cannot yet be observed with the current resolution on the transition.
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.