Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Journal of Physics

The three-grating Mach Zehnder optical interferometer: a tutorial approach using particle optics

Alain Miffre, R. Delhuille, B. Viaris de Lesegno, M Büchner, Carlo Rizzo, J. Vigué

Published Oct 15, 2002• 10 citations
Publisher

Abstract

In this paper, we present a tutorial set-up based on an optical three-grating Mach–Zehnder interferometer. As this apparatus is very similar in its principle to the Mach–Zehnder interferometers used with matter waves (neutrons, atoms and molecules), it can be used to familiarize students with particle optics, and in our explanations, we use the complementary points of view of wave optics and particle optics. Finally, we have used this interferometer to measure the index of refraction of BK 7 glass for red light at 633 nm, with a technique equivalent to the one used to measure the index of refraction of solid matter for thermal neutrons. The dimensions of this interferometer and its cost make it very interesting for laboratory courses and the experiment described here can be reproduced by students.

DOI
10.1088/0143-0807/23/6/304

Related papers

The wave-particle duality of light: A demonstration experiment

Todorka L. Dimitrova, Antoine Weis

The wave-particle duality of light plays a fundamental role in introductory courses on quantum mechanics. Traditionally the wave and particle aspects of light are demonstrated in separate experiments which makes it difficult for students to understand their complementary nature. We present an experiment using a single apparatus that demonstrates the wave aspect, the particle aspect, and most importantly, their coexistence. The apparatus is based on a Mach-Zehnder interferometer in which a light beam is attenuated so that at each instant there is only a single photon in the interferometer. In this way the observation of single photon interference becomes possible. By integrating the single photon events in a storage oscilloscope the evolution toward classical interference fringes can be shown in real time. A second strong laser beam, derived from the same pointer, but slightly displaced, traverses the interferometer at the same time, allowing the simultaneous demonstration of wave aspects. Special features of the setup are low cost, simplicity, didactical power and suitability for presentations in large lecture halls using both multimedia projections and audible signals.

American Journal of Physics•Jan 12, 2008•92 citations

Atom Interferometry

Peter Hannaford

Matter - wave interferometry began with the development of electron interferometers and neutron interferometers in the 1950s and 1960s, but it wasn't until 1991 that the first atom matter - wave interferometer was realized. This was followed by a surge of activity sparked by the advent of sources of ultracold laser-cooled atoms. Some of the potential advantages of atom interferometry over neutron interferometry include: much higher particle fluxes, lower particle velocities, larger particle masses, particles with internal states, and laboratory-based sources. This volume is the first text on atom interferometry. It consists of ten comprehensive review articles by leading researchers in the field, many of whom pioneered the first atom interferometers in 1991. The articles describe the different types of atom interferometers developed to date, ranging from the three-grating Mach - Zehnder interferometer based on nanofabricated grating structures (MIT) or standing-wave light-field gratings (Innsbruck), to the Talbot - Lau atom interferometer (Berkeley and Michigan), to atom interferometers based on internal-state labelling such as separated light-field interferometers (PTB, Hannover and Paris-Nord) and light-pulse interferometers (Stanford). Some of the recent applications of atom interferometry described in the articles include high precision measurements of rotations, the gravitational acceleration, and the fine structure constant (Stanford); measurements of topological phases (PTB and Hannover); correlation experiments with atoms and photons (Konstanz) and with pairs of atoms (Tokyo); holographic manipulation of atoms (Tokyo); and experiments on the quantum theory of measurement (Garching, Harvard and Texas A&M). In summary, this volume provides an excellent up-to-date account of atom interferometry and is recommended as essential reading for all researchers and would-be researchers in the field. At the same time it contains sufficient background material and theory to serve as an excellent introduction for the non-specialist. The field is presently moving at such a rapid pace, however, that many of the latest results reported in this volume will already have been superseded by the time it reaches the library shelves.

Measurement Science and Technology•Sep 1, 1997•1 citation

Measuring decoherence and the matter-wave index of refraction with an improved atom interferometer

David A. Kokorowski

This thesis describes experiments performed using the MIT atom interferometer, which has recently been upgraded to provide increased experimental precision and flexibility. The three-gratings comprising our Mach-Zehnder interferometer have been installed on a vibration isolated platform which has reduced rms motion of the gratings by a factor of two. The arrangement of gratings on the platform can be reconfigured at will, and the entire platform removed from the vacuum chamber for purposes of alignment. We have performed a series of experiments related to decoherence in an atom interferometer. We have explored decoherence due to photon scattering, in particular the transition from single- to multiple-photon decoherence, and have quantitatively verified the decoherence rate constant in the many-photon regime. We have also examined decoherence due to background gas scattering. Finally, we have investigated the distinction between decoherence and classical dephasing by comparing experiments which illustrate each of these phenomena. We have made new measurements of the index of refraction of argon for sodium matter-waves. Our results are twice as precise previous measurements but suffer from significant systematic error. A detailed study of systematics is presented along with concrete proposals for minimizing their effect in future matter-wave index of refraction measurements.

•Jan 1, 2001•2 citations

Measurement of the refraction index for atom waves

Marion Jacquey, M Büchner, G. Trénec +1 more

We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.

Annales de Physique•Jan 1, 2007•0 citations

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

Oxford University Press eBooks•Aug 10, 2000•0 citations

Electron matter optics and an electron Mach -Zehnder interferometer

Glen Gronniger

The diffraction of electrons by natural crystal structures was first observed in 1927. Before the start of this work, it was not clear whether or not the high quality gratings currently available could be used for electron diffraction due to image charge and other electron grating interactions. We observe for the first time electron diffraction from man made diffraction gratings of 100 nm periodicity. The high quality of diffraction and the ability to "pick" the periodicity allowed us to construct the first Mach-Zehnder electron interferometer using these gratings. Multiple approaches, including a prototype of our current interferometer and the combination of a grating with an electron bi-prism, were unsuccessful. Many stabilization issues must be overcome to observe electron interference fringes in the interferometer. Many experimental design ideas were used to reach proper stabilization requirements. The final interferometer design constructed was the only interferometer to obtain electron interference fringes. The theoretical model used to analyze the data is based on the path integral formalism. This calculates the amplitude associated with all classical paths through the experimental device. The sum of all amplitudes, the path integral, yields the resulting probability at the detection screen. We obtain good fits between our path integral calculations and experimental data. Alternate explanations of our data, such as the possibilities of Talbot Lau and classical Moiré interferometers are ruled out in favor of the Mach-Zehnder explanation. This type of interferometer could be used for future experiments. An experiment for which the fundamental quantum mechanical experiment has never been done; observing the dispersion-less nature of the Aharonov-Bohm Effect, may lend itself to the characteristics of this type of interferometer. Preliminary calculations have been performed to investigate the feasibility of using the grating technology to perform the required experiment.

•Jan 1, 2006•0 citations
In this paper, we present a tutorial set-up based on an optical three-grating Mach–Zehnder interferometer. As this apparatus is very similar in its principle to the Mach–Zehnder interferometers used with matter waves (neutrons, atoms and molecules), it can be used to familiarize students with particle optics, and in our explanations, we use the complementary points of view of wave optics and particle optics. Finally, we have used this interferometer to measure the index of refraction of BK 7 glass for red light at 633 nm, with a technique equivalent to the one used to measure the index of refraction of solid matter for thermal neutrons. The dimensions of this interferometer and its cost make it very interesting for laboratory courses and the experiment described here can be reproduced by students.
The wave-particle duality of light plays a fundamental role in introductory courses on quantum mechanics. Traditionally the wave and particle aspects of light are demonstrated in separate experiments which makes it difficult for students to understand their complementary nature. We present an experiment using a single apparatus that demonstrates the wave aspect, the particle aspect, and most importantly, their coexistence. The apparatus is based on a Mach-Zehnder interferometer in which a light beam is attenuated so that at each instant there is only a single photon in the interferometer. In this way the observation of single photon interference becomes possible. By integrating the single photon events in a storage oscilloscope the evolution toward classical interference fringes can be shown in real time. A second strong laser beam, derived from the same pointer, but slightly displaced, traverses the interferometer at the same time, allowing the simultaneous demonstration of wave aspects. Special features of the setup are low cost, simplicity, didactical power and suitability for presentations in large lecture halls using both multimedia projections and audible signals.
Matter - wave interferometry began with the development of electron interferometers and neutron interferometers in the 1950s and 1960s, but it wasn't until 1991 that the first atom matter - wave interferometer was realized. This was followed by a surge of activity sparked by the advent of sources of ultracold laser-cooled atoms. Some of the potential advantages of atom interferometry over neutron interferometry include: much higher particle fluxes, lower particle velocities, larger particle masses, particles with internal states, and laboratory-based sources. This volume is the first text on atom interferometry. It consists of ten comprehensive review articles by leading researchers in the field, many of whom pioneered the first atom interferometers in 1991. The articles describe the different types of atom interferometers developed to date, ranging from the three-grating Mach - Zehnder interferometer based on nanofabricated grating structures (MIT) or standing-wave light-field gratings (Innsbruck), to the Talbot - Lau atom interferometer (Berkeley and Michigan), to atom interferometers based on internal-state labelling such as separated light-field interferometers (PTB, Hannover and Paris-Nord) and light-pulse interferometers (Stanford). Some of the recent applications of atom interferometry described in the articles include high precision measurements of rotations, the gravitational acceleration, and the fine structure constant (Stanford); measurements of topological phases (PTB and Hannover); correlation experiments with atoms and photons (Konstanz) and with pairs of atoms (Tokyo); holographic manipulation of atoms (Tokyo); and experiments on the quantum theory of measurement (Garching, Harvard and Texas A&M). In summary, this volume provides an excellent up-to-date account of atom interferometry and is recommended as essential reading for all researchers and would-be researchers in the field. At the same time it contains sufficient background material and theory to serve as an excellent introduction for the non-specialist. The field is presently moving at such a rapid pace, however, that many of the latest results reported in this volume will already have been superseded by the time it reaches the library shelves.
This thesis describes experiments performed using the MIT atom interferometer, which has recently been upgraded to provide increased experimental precision and flexibility. The three-gratings comprising our Mach-Zehnder interferometer have been installed on a vibration isolated platform which has reduced rms motion of the gratings by a factor of two. The arrangement of gratings on the platform can be reconfigured at will, and the entire platform removed from the vacuum chamber for purposes of alignment. We have performed a series of experiments related to decoherence in an atom interferometer. We have explored decoherence due to photon scattering, in particular the transition from single- to multiple-photon decoherence, and have quantitatively verified the decoherence rate constant in the many-photon regime. We have also examined decoherence due to background gas scattering. Finally, we have investigated the distinction between decoherence and classical dephasing by comparing experiments which illustrate each of these phenomena. We have made new measurements of the index of refraction of argon for sodium matter-waves. Our results are twice as precise previous measurements but suffer from significant systematic error. A detailed study of systematics is presented along with concrete proposals for minimizing their effect in future matter-wave index of refraction measurements.
We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.
Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).
The diffraction of electrons by natural crystal structures was first observed in 1927. Before the start of this work, it was not clear whether or not the high quality gratings currently available could be used for electron diffraction due to image charge and other electron grating interactions. We observe for the first time electron diffraction from man made diffraction gratings of 100 nm periodicity. The high quality of diffraction and the ability to "pick" the periodicity allowed us to construct the first Mach-Zehnder electron interferometer using these gratings. Multiple approaches, including a prototype of our current interferometer and the combination of a grating with an electron bi-prism, were unsuccessful. Many stabilization issues must be overcome to observe electron interference fringes in the interferometer. Many experimental design ideas were used to reach proper stabilization requirements. The final interferometer design constructed was the only interferometer to obtain electron interference fringes. The theoretical model used to analyze the data is based on the path integral formalism. This calculates the amplitude associated with all classical paths through the experimental device. The sum of all amplitudes, the path integral, yields the resulting probability at the detection screen. We obtain good fits between our path integral calculations and experimental data. Alternate explanations of our data, such as the possibilities of Talbot Lau and classical Moiré interferometers are ruled out in favor of the Mach-Zehnder explanation. This type of interferometer could be used for future experiments. An experiment for which the fundamental quantum mechanical experiment has never been done; observing the dispersion-less nature of the Aharonov-Bohm Effect, may lend itself to the characteristics of this type of interferometer. Preliminary calculations have been performed to investigate the feasibility of using the grating technology to perform the required experiment.