Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Experimental and Theoretical Physics Letters

Two methods for detecting nonclassical correlations in parametric scattering of light

T. Sh. Iskhakov, E. D. Lopaeva, Alexander N. Penin, Georgy O. Rytikov, Maria V. Chekhova

Published Jan 1, 2008• 19 citations
Publisher

Abstract

Two methods for studying nonclassical correlations at the output of a two-mode parametric amplifier—first, the measurement of normalized Glauber correlation functions and, second, the measurement of the variance of the photon-number difference in conjugate modes—are compared. It is shown theoretically and experimentally that the corresponding quantities, the normalized correlation function, and the noise reduction factor have significantly different dependences on the main system parameters such as the parametric gain, optical losses, photo-detector quantum efficiency, and the detected angular and frequency bands.

DOI
10.1134/s0021364008220050

Related papers

Measurement of the Quantum Efficiency of Analog Detectors in the Parametric Down-Conversion Field

T. I. Novikova, A.A. Leontyev, G. Kh. Kitaeva

Approaches to the standard-free calibration of the quantum efficiency of a wide class of analog detectors based on the measurement of statistical characteristics of fields generated by parametric down-conversion are analyzed. General expressions are obtained for the noise reduction factor of the difference photocurrent and for the covariance of photocurrents in the signal and idler channels that take into account the possibility of strong fluctuations in the amplitudes of single-photon response functions of the detectors used. It is shown that the measurement of the noise reduction factor of the difference photocurrent using detectors that cannot operate in the photon counting mode is on its own insufficient to directly characterize the level of two-mode squeezing in the down-conversion field and to determine the quantum efficiency of photosensitive elements without additional calibration procedures. A method to determine the quantum efficiency of such detectors based on measuring the dependence of the normalized covariance of photocurrents on the parametric gain is proposed.

Journal of Experimental and Theoretical Physics Letters•Sep 1, 2022•3 citations

Measurement of quantum-noise correlations in parametric image amplification

M. Marable, Sang Kyung Choi, Prem Kumar

We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.

Optics Express•Feb 2, 1998•20 citations

Measurement of the biphoton second-order correlation function with analog detectors

Daniil A. Safronenkov, N. A. Borshchevskaya, T. I. Novikova +3 more

An experimental scheme and data processing approaches are proposed for measuring by analog photo detectors the normalized second-order correlation function of the biphoton field generated under spontaneous parametric down-conversion. Obtained results are especially important for quantum SPDC-based technologies in the long-wave spectral ranges, where it is difficult to use the single-photon detector at least in one of the two biphoton channels. The methods of discrimination of analog detection samples are developed to eliminate the negative influence of the detection noises and get quantitatively true values of both the correlation function and the detector quantum efficiency. The methods are demonstrated depending on whether two single-photon avalanche photo detectors are used in both SPDC channels, or at least one single-photon detector is replaced by a photo-multiplier tube which cannot operate in the photon counting mode.

Optics Express•Oct 15, 2021•11 citations

Correlation Properties of an Optical–Terahertz Biphoton Field

Pavel A. Prudkovskii

The effect of the structure of angular modes of an optical–terahertz biphoton field appearing in strongly nondegenerate parametric down-conversion on the possibility of measuring nonclassical correlation properties of this field has been studied theoretically. It has been shown that the nonlinear interaction operator describing parametric down-conversion can be diagonalized in the space of azimuth angles if idler radiation has a terahertz frequency. This feature makes it possible to determine azimuthal eigenmodes and the scattering matrix at arbitrary coefficients of the parametric gain. The determined scattering matrix has been used to find the dependences of the normalized correlation function and the noise reduction factor of the optical–terahertz biphoton field on the angular apertures of detectors recording the signal and idler radiation.

Journal of Experimental and Theoretical Physics Letters•Aug 1, 2021•7 citations

Detection of two-mode compression and degree of entanglement in continuous variables in parametric scattering of light

Georgy O. Rytikov, Maria V. Chekhova

Generation of “twin beams” (of light with two-mode compression) in single-pass optical parametric amplifier (a crystal with a nonzero quadratic susceptibility) is considered. Radiation at the output of the nonlinear crystal is essentially multimode, which raises the question about the effect of the detection volume on the extent of suppression of noise from the difference photocurrent of the detectors. In addition, the longitudinal as well as transverse size of the region in which parametric transformation takes place is of fundamental importance. It is shown that maximal suppression of noise from difference photocurrent requires a high degree of entanglement of two-photon light at the outlet of the parametric amplifier, which is defined by Federov et al. [Phys. Rev. A 77 , 032336 (2008)] as the ratio of the intensity distribution width to the correlation function width. The detection volume should be chosen taking into account both these quantities. Various modes of single-pass generation of twin beams (noncollinear frequency-degenerate and collinear frequency-nondegenerate synchronism of type I, as well as collinear frequency-degenerate synchronism of type II) are considered in connection with the degree of entanglement.

Journal of Experimental and Theoretical Physics•Dec 1, 2008•8 citations

Direct observation of the degree of correlations using photon-number-resolving detectors

Liat Dovrat, Michael Bakstein, D. Istrati +4 more

Optical parametric down-conversion is a common source for the generation of nonclassical correlated photonic states. Using a parametric down-conversion source and photon-number-resolving detectors, we measure the two-mode photon-number distribution of up to 10 photons for different degrees of correlation. The degree of correlation is controlled by collecting different spatial and spectral single modes for each polarization and varying the amount of spectral and spatial overlap between them. Clear evidence for photon-number correlations is presented despite detector imperfections such as low detection efficiency and other distorting effects. Two criteria, derived directly from the raw data, are shown to be good measures for the degree of correlation. Additionally, using a fitting technique, we find a connection between the measured photon-number distribution and the degree of correlation of the reconstructed original two-mode state. These observations are only possible as a result of the detection of high photon number events.

arXiv:1210.0751•Physical Review A•May 9, 2013•15 citations
Two methods for studying nonclassical correlations at the output of a two-mode parametric amplifier—first, the measurement of normalized Glauber correlation functions and, second, the measurement of the variance of the photon-number difference in conjugate modes—are compared. It is shown theoretically and experimentally that the corresponding quantities, the normalized correlation function, and the noise reduction factor have significantly different dependences on the main system parameters such as the parametric gain, optical losses, photo-detector quantum efficiency, and the detected angular and frequency bands.
Approaches to the standard-free calibration of the quantum efficiency of a wide class of analog detectors based on the measurement of statistical characteristics of fields generated by parametric down-conversion are analyzed. General expressions are obtained for the noise reduction factor of the difference photocurrent and for the covariance of photocurrents in the signal and idler channels that take into account the possibility of strong fluctuations in the amplitudes of single-photon response functions of the detectors used. It is shown that the measurement of the noise reduction factor of the difference photocurrent using detectors that cannot operate in the photon counting mode is on its own insufficient to directly characterize the level of two-mode squeezing in the down-conversion field and to determine the quantum efficiency of photosensitive elements without additional calibration procedures. A method to determine the quantum efficiency of such detectors based on measuring the dependence of the normalized covariance of photocurrents on the parametric gain is proposed.
We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.
An experimental scheme and data processing approaches are proposed for measuring by analog photo detectors the normalized second-order correlation function of the biphoton field generated under spontaneous parametric down-conversion. Obtained results are especially important for quantum SPDC-based technologies in the long-wave spectral ranges, where it is difficult to use the single-photon detector at least in one of the two biphoton channels. The methods of discrimination of analog detection samples are developed to eliminate the negative influence of the detection noises and get quantitatively true values of both the correlation function and the detector quantum efficiency. The methods are demonstrated depending on whether two single-photon avalanche photo detectors are used in both SPDC channels, or at least one single-photon detector is replaced by a photo-multiplier tube which cannot operate in the photon counting mode.
The effect of the structure of angular modes of an optical–terahertz biphoton field appearing in strongly nondegenerate parametric down-conversion on the possibility of measuring nonclassical correlation properties of this field has been studied theoretically. It has been shown that the nonlinear interaction operator describing parametric down-conversion can be diagonalized in the space of azimuth angles if idler radiation has a terahertz frequency. This feature makes it possible to determine azimuthal eigenmodes and the scattering matrix at arbitrary coefficients of the parametric gain. The determined scattering matrix has been used to find the dependences of the normalized correlation function and the noise reduction factor of the optical–terahertz biphoton field on the angular apertures of detectors recording the signal and idler radiation.
Generation of “twin beams” (of light with two-mode compression) in single-pass optical parametric amplifier (a crystal with a nonzero quadratic susceptibility) is considered. Radiation at the output of the nonlinear crystal is essentially multimode, which raises the question about the effect of the detection volume on the extent of suppression of noise from the difference photocurrent of the detectors. In addition, the longitudinal as well as transverse size of the region in which parametric transformation takes place is of fundamental importance. It is shown that maximal suppression of noise from difference photocurrent requires a high degree of entanglement of two-photon light at the outlet of the parametric amplifier, which is defined by Federov et al. [Phys. Rev. A 77 , 032336 (2008)] as the ratio of the intensity distribution width to the correlation function width. The detection volume should be chosen taking into account both these quantities. Various modes of single-pass generation of twin beams (noncollinear frequency-degenerate and collinear frequency-nondegenerate synchronism of type I, as well as collinear frequency-degenerate synchronism of type II) are considered in connection with the degree of entanglement.
Optical parametric down-conversion is a common source for the generation of nonclassical correlated photonic states. Using a parametric down-conversion source and photon-number-resolving detectors, we measure the two-mode photon-number distribution of up to 10 photons for different degrees of correlation. The degree of correlation is controlled by collecting different spatial and spectral single modes for each polarization and varying the amount of spectral and spatial overlap between them. Clear evidence for photon-number correlations is presented despite detector imperfections such as low detection efficiency and other distorting effects. Two criteria, derived directly from the raw data, are shown to be good measures for the degree of correlation. Additionally, using a fitting technique, we find a connection between the measured photon-number distribution and the degree of correlation of the reconstructed original two-mode state. These observations are only possible as a result of the detection of high photon number events.