Optics Express

Measurement of quantum-noise correlations in parametric image amplification

M. Marable, Sang Kyung Choi, Prem Kumar

Published Feb 2, 1998• 20 citations
Publisher

Abstract

We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.

DOI
10.1364/oe.2.000084

Related papers

Observation of Noiseless Image Amplification by an Optical Parametric Amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

A spatially-broadband optical parametric amplifier is used for image amplification. In the phase-sensitive configuration, we observe a noise figure of −0.1± 0.3dB for a gain of 2.4, which is 2dB lower than the quantum limit for an ideal phase-insensitive amplifier. Image pre-amplification before loss is shown to improve the detected signal-to-noise ratio.

Kluwer Academic Publishers eBooks•Dec 19, 2005•1 citation

Noiseless Optical Amplification of Images

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

We used a spatially broadband optical parametric amplifier for image amplification. In the phase-sensitive configuration of the amplifier, we observed noiseless amplification of input images. For a gain of $\ensuremath{\simeq}2.5$, we measured noise-figure values of ( $0.2\ifmmode\pm\else\textpm\fi{}0.6$) and ( $0.4\ifmmode\pm\else\textpm\fi{}0.5$) dB, respectively, for two amplifiers of different lengths. These experimental values agree with theory (for an ideal noiseless amplifier the noise figure is 0 dB) and are almost 2 dB lower than the quantum limit of an ideal phase-insensitive amplifier.

Physical Review Letters•Sep 6, 1999•135 citations

Noiseless image amplification by a phase-sensitive parametric amplifier

Sang-Kyung Choi, Michael Vasilyev, Prem Kumar

Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.

Conference on Lasers and Electro-Optics•Jan 1, 1998•1 citation

Quantum noise reduction in optical amplification

Z. Y. Ou, Silvania F. Pereira, Harry J. Kimble

Quantum fluctuations in optical amplification are investigated with a nondegenerate optical parametric amplifier whose internal idler mode is coupled to a squeezed vacuum. Reductions of the inherent quantum noise of the amplifier are observed with a minimum noise level 0.7 dB below the usual noise level of the amplifier with its internal idler mode in a vacuum state. With a small coherent field as the signal input, the amplified output exhibits an improvement in signal-to-noise ratio of 0.5 dB for the case of a squeezed-vacuum as compared to a vacuum state for the amplifier's internal mode.

Physical Review Letters•May 24, 1993•98 citations

Quantum amplification and quantum optical tapping with squeezed states and correlated quantum states

Z. Y. Ou, Silvania F. Pereira, Harry J. Kimble

Quantum fluctuations in a nondegenerate optical parametric amplifier (NOPA) are investigated experimentally with a squeezed state coupled into the internal idler mode of the NOPA. Reductions of the inherent quantum noise of the amplifier are observed with a minimum noise level 0.7 dB below the usual noise level of the amplifier with its idler mode in a vacuum state. With two correlated quantum fields as the amplifier's inputs and proper adjustment of the gain of the amplifier, it is shown that the amplifier's intrinsic quantum noise can be completely suppressed so that noise-free amplification is achieved. It is also shown that the NOPA, when coupled to either a squeezed state or a nonclassically correlated state, can realize quantum tapping of optical information.

•May 1, 1994•0 citations

Observation of twin-beam-type quantum correlation in optical fiber

Jay E. Sharping, Marco Fiorentino B, Prem Kumar

We report generation of pulsed twin beams of light through optical parametric amplification in a fiber Sagnac loop. By pumping the Sagnac loop with picosecond pulses at a wavelength near the zero-dispersion wavelength of the fiber, we achieve phase-matched nondegenerate four-wave mixing with gain. For a gain of 2.2, the intensity noises of the amplified signal and the generated idler (conjugate) pulses are found to be correlated by 5.0 dB, and the subtracted noise drops below the shot-noise limit by 1.1 dB (2.6 dB when corrected for losses). We have investigated the gain dependence of the quantum-noise reduction as well as of the intensity noises of the amplified signal and idler pulses. As the gain increases, we observe the onset of excess noise on the idler pulses.

Optics Letters•Mar 15, 2001•102 citations
We demonstrate quantum-noise correlations between the spatial frequencies of a parametrically amplified signal image and the generated conjugate (idler) image. Test images were amplified by an optical parametric amplifier that can be operated either as a low-pass or a band-pass amplifier for spatial frequencies. Direct difference detection of the signal and idler spatial frequencies at +- 16 mm{;{-1}} resulted in noise that fell below the shot-noise level by approx. 5 dB. Parametric-gain and phase-mismatch dependence of the observed quantum-noise reduction is in good agreement with the theory of a spatially-broadband optical parametric amplifier.
We used a spatially broadband optical parametric amplifier for image amplification. In the phase-sensitive configuration of the amplifier, we observed noiseless amplification of input images. For a gain of $\ensuremath{\simeq}2.5$, we measured noise-figure values of ( $0.2\ifmmode\pm\else\textpm\fi{}0.6$) and ( $0.4\ifmmode\pm\else\textpm\fi{}0.5$) dB, respectively, for two amplifiers of different lengths. These experimental values agree with theory (for an ideal noiseless amplifier the noise figure is 0 dB) and are almost 2 dB lower than the quantum limit of an ideal phase-insensitive amplifier.
Summary form only given. Optical imaging is one of the important potential applications for nonclassic states of light. It has been shown that spatially broadband squeezed light can be used to image faint objects with sub-shot-noise sensitivity. Broad spatial bandwidth of an optical parametric amplifier (OPA), determined by phase-matching conditions, makes it a good choice for studying the feasibility of imaging with nonclassic states. Here, we report, to our knowledge, the first observation of noiseless amplification of an image by means of phase-sensitive parametric amplification.
Quantum fluctuations in optical amplification are investigated with a nondegenerate optical parametric amplifier whose internal idler mode is coupled to a squeezed vacuum. Reductions of the inherent quantum noise of the amplifier are observed with a minimum noise level 0.7 dB below the usual noise level of the amplifier with its internal idler mode in a vacuum state. With a small coherent field as the signal input, the amplified output exhibits an improvement in signal-to-noise ratio of 0.5 dB for the case of a squeezed-vacuum as compared to a vacuum state for the amplifier's internal mode.
Quantum fluctuations in a nondegenerate optical parametric amplifier (NOPA) are investigated experimentally with a squeezed state coupled into the internal idler mode of the NOPA. Reductions of the inherent quantum noise of the amplifier are observed with a minimum noise level 0.7 dB below the usual noise level of the amplifier with its idler mode in a vacuum state. With two correlated quantum fields as the amplifier's inputs and proper adjustment of the gain of the amplifier, it is shown that the amplifier's intrinsic quantum noise can be completely suppressed so that noise-free amplification is achieved. It is also shown that the NOPA, when coupled to either a squeezed state or a nonclassically correlated state, can realize quantum tapping of optical information.
We report generation of pulsed twin beams of light through optical parametric amplification in a fiber Sagnac loop. By pumping the Sagnac loop with picosecond pulses at a wavelength near the zero-dispersion wavelength of the fiber, we achieve phase-matched nondegenerate four-wave mixing with gain. For a gain of 2.2, the intensity noises of the amplified signal and the generated idler (conjugate) pulses are found to be correlated by 5.0 dB, and the subtracted noise drops below the shot-noise limit by 1.1 dB (2.6 dB when corrected for losses). We have investigated the gain dependence of the quantum-noise reduction as well as of the intensity noises of the amplified signal and idler pulses. As the gain increases, we observe the onset of excess noise on the idler pulses.