Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Experimental and Theoretical Physics

Detection of two-mode compression and degree of entanglement in continuous variables in parametric scattering of light

Georgy O. Rytikov, Maria V. Chekhova

Published Dec 1, 2008• 8 citations
Publisher

Abstract

Generation of “twin beams” (of light with two-mode compression) in single-pass optical parametric amplifier (a crystal with a nonzero quadratic susceptibility) is considered. Radiation at the output of the nonlinear crystal is essentially multimode, which raises the question about the effect of the detection volume on the extent of suppression of noise from the difference photocurrent of the detectors. In addition, the longitudinal as well as transverse size of the region in which parametric transformation takes place is of fundamental importance. It is shown that maximal suppression of noise from difference photocurrent requires a high degree of entanglement of two-photon light at the outlet of the parametric amplifier, which is defined by Federov et al. [Phys. Rev. A 77 , 032336 (2008)] as the ratio of the intensity distribution width to the correlation function width. The detection volume should be chosen taking into account both these quantities. Various modes of single-pass generation of twin beams (noncollinear frequency-degenerate and collinear frequency-nondegenerate synchronism of type I, as well as collinear frequency-degenerate synchronism of type II) are considered in connection with the degree of entanglement.

DOI
10.1134/s1063776108120029

Related papers

Precision measurements with twin beams of light

Prem Kumar

The generation of twin beams of light from an optical parametric amplifier (OPA) pumped by the second harmonic of a mode-locked and Q-Switched Nd:YAG laser has recently been reported.1 The intensity noises on the direct- detected signal and idler beams at the output of the OPA were observed to be correlated by more than 15 dB, and the subtracted noise fell below the quantum limit by up to 7 dB (80%). With the same OPA it is much harder to generate and detect a highly squeezed beam of light.

Quantum Electronics and Laser Science Conference•May 12, 1991•0 citations

Multimode detection of broadband squeezed vacuum

Agafonov Ivan, Chekhova Maria, T. Sh. Iskhakov +1 more

Squeezed vacuum with large photon numbers is an example of a macroscopic system with nonclassical properties. These properties are manifested in pairwise intensity correlations, also called twin-beam squeezing. We produce squeezed vacuum in a traveling-wave pulse-pumped frequency non-degenerate optical parametric amplifier (NOPA). Twin-beam squeezing is measured via direct detection and measurement of the difference-signal variance for two balanced detectors. It is shown that the study of the intensity correlations using this method requires a collection of a large number of modes, both longitudinal and transverse.

NATO science for peace and security series. D, Information and communication security•Jan 1, 2010•1 citation

Equivalence of twin beams and squeezed states in a nondegenerate optical parametric amplifier

Chonghoon Kim, Prem Kumar

Twin beams generated from a nondegenerate optical parametric amplifier (NOPA) of gaing possess1 an intensity correlation that falls below the quantum limit by (2g – 1). This occurs whenever the input idler to the NOPA is in the vacuum state. Such input is practically advantageous because it makes the NOPA output intensities phase insensitive. When a non-vacuum idler input state is chosen, the NOPA output intensities become phase sensitive. For a proper input state and a suitable pump phase the output intensity correlation falls below the quantum limit by ( g + g − 1 ) 2 , which is 3 dB superior to the vacuum-idler-input result for g >> 1 and is equivalent to the quantum-noise reduction obtainable from a squeezed state generated with the same gain. Thus the sensitivity improvement achievable with NOPA twin beams by using direct detection is equivalent to that obtainable with squeezed states by using homodyne detection. The above equivalence also provides a new scheme for the generation of pulsed squeezed light that, in addition to being simple, automatically generates a matched local oscillator2 for homodyne detection of the squeezed pulses.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Experimental generation of 84 dB entangled state with an optical cavity involving a wedged type-II nonlinear crystal

Yaoyao Zhou, Xiaojun Jia, Fang Li +2 more

Entangled state of light is one of the essential quantum resources in quantum information science and technology. Especially, when the fundamental principle experiments have been achieved in labs and the applications of continuous variable quantum information in the real world are considered, it is crucial to design and construct the generation devices of entangled states with high entanglement and compact configuration. We have designed and built an efficient and compact light source of entangled state, which is a non-degenerate optical parametric amplifier (NOPA) with the triple resonance of the pump and two subharmonic modes. A wedged type-II KTP crystal inside the NOPA is used for implementing frequency-down-conversion of the pump field to generate the optical entangled state and achieving the dispersion compensation between the pump and the subharmonic waves. The EPR entangled state of light with quantum correlations of 8.4 dB for both amplitude and phase quadratures are experimentally produced by a single NOPA under the pump power of 75 mW.

arXiv:1502.07416•Optics Express•Feb 17, 2015•55 citations

Generation and homodyne detection of continuous-variable entangled optical beams with a large wavelength difference

Xiaomin Guo, Changde Xie, Yongmin Li

We present a scheme for generating and homodyne detecting of continuous-variable entanglement of bright optical beams with a large wavelength difference by utilizing an optical parametric oscillator (OPO) and an optical parametric amplifier (OPA) simultaneously. Entangled optical beams at 0.8 and 1.5 \ensuremath{\mu}m are generated from the OPA; the seed beams injected in the OPA as well as the local oscillators at the two wavelengths needed for homodyne detection are provided by the OPO. The entangler is a ring resonator involving a second-order nonlinear crystal that is pumped from two opposite directions. In one direction the pump power is above the oscillation threshold and the optical nonlinear resonator operates as an OPO. In the other direction the pump power is below the threshold and it operates as a phase-sensitive frequency nondegenerate optical parametric amplifier. Our scheme combines the advantages of both OPO and OPA quantum optical devices and opens another avenue for preparation and homodyne detection of high quality bright entangled light with a large wavelength difference.

Physical Review A•Aug 2, 2011•14 citations

Experimental generation of 6 dB continuous variable entanglement from a nondegenerate optical parametric amplifier

Yu Wang, Heng Shen, Xiaoli Jin +3 more

We experimentally demonstrated that the quantum correlations of amplitude and phase quadratures between signal and idler beams produced from a non-degenerate optical parametric amplifier (NOPA) can be significantly improved by using a mode cleaner in the pump field and reducing the phase fluctuations in phase locking systems. Based on the two technical improvements the quantum entanglement measured with a two-mode homodyne detector is enhanced from approximately 4 dB to approximately 6 dB below the quantum noise limit using the same NOPA and nonlinear crystal.

arXiv:1003.2460•Optics Express•Mar 11, 2010•53 citations
Generation of “twin beams” (of light with two-mode compression) in single-pass optical parametric amplifier (a crystal with a nonzero quadratic susceptibility) is considered. Radiation at the output of the nonlinear crystal is essentially multimode, which raises the question about the effect of the detection volume on the extent of suppression of noise from the difference photocurrent of the detectors. In addition, the longitudinal as well as transverse size of the region in which parametric transformation takes place is of fundamental importance. It is shown that maximal suppression of noise from difference photocurrent requires a high degree of entanglement of two-photon light at the outlet of the parametric amplifier, which is defined by Federov et al. [Phys. Rev. A 77 , 032336 (2008)] as the ratio of the intensity distribution width to the correlation function width. The detection volume should be chosen taking into account both these quantities. Various modes of single-pass generation of twin beams (noncollinear frequency-degenerate and collinear frequency-nondegenerate synchronism of type I, as well as collinear frequency-degenerate synchronism of type II) are considered in connection with the degree of entanglement.
Squeezed vacuum with large photon numbers is an example of a macroscopic system with nonclassical properties. These properties are manifested in pairwise intensity correlations, also called twin-beam squeezing. We produce squeezed vacuum in a traveling-wave pulse-pumped frequency non-degenerate optical parametric amplifier (NOPA). Twin-beam squeezing is measured via direct detection and measurement of the difference-signal variance for two balanced detectors. It is shown that the study of the intensity correlations using this method requires a collection of a large number of modes, both longitudinal and transverse.
Twin beams generated from a nondegenerate optical parametric amplifier (NOPA) of gaing possess1 an intensity correlation that falls below the quantum limit by (2g – 1). This occurs whenever the input idler to the NOPA is in the vacuum state. Such input is practically advantageous because it makes the NOPA output intensities phase insensitive. When a non-vacuum idler input state is chosen, the NOPA output intensities become phase sensitive. For a proper input state and a suitable pump phase the output intensity correlation falls below the quantum limit by ( g + g − 1 ) 2 , which is 3 dB superior to the vacuum-idler-input result for g >> 1 and is equivalent to the quantum-noise reduction obtainable from a squeezed state generated with the same gain. Thus the sensitivity improvement achievable with NOPA twin beams by using direct detection is equivalent to that obtainable with squeezed states by using homodyne detection. The above equivalence also provides a new scheme for the generation of pulsed squeezed light that, in addition to being simple, automatically generates a matched local oscillator2 for homodyne detection of the squeezed pulses.
Entangled state of light is one of the essential quantum resources in quantum information science and technology. Especially, when the fundamental principle experiments have been achieved in labs and the applications of continuous variable quantum information in the real world are considered, it is crucial to design and construct the generation devices of entangled states with high entanglement and compact configuration. We have designed and built an efficient and compact light source of entangled state, which is a non-degenerate optical parametric amplifier (NOPA) with the triple resonance of the pump and two subharmonic modes. A wedged type-II KTP crystal inside the NOPA is used for implementing frequency-down-conversion of the pump field to generate the optical entangled state and achieving the dispersion compensation between the pump and the subharmonic waves. The EPR entangled state of light with quantum correlations of 8.4 dB for both amplitude and phase quadratures are experimentally produced by a single NOPA under the pump power of 75 mW.
We present a scheme for generating and homodyne detecting of continuous-variable entanglement of bright optical beams with a large wavelength difference by utilizing an optical parametric oscillator (OPO) and an optical parametric amplifier (OPA) simultaneously. Entangled optical beams at 0.8 and 1.5 \ensuremath{\mu}m are generated from the OPA; the seed beams injected in the OPA as well as the local oscillators at the two wavelengths needed for homodyne detection are provided by the OPO. The entangler is a ring resonator involving a second-order nonlinear crystal that is pumped from two opposite directions. In one direction the pump power is above the oscillation threshold and the optical nonlinear resonator operates as an OPO. In the other direction the pump power is below the threshold and it operates as a phase-sensitive frequency nondegenerate optical parametric amplifier. Our scheme combines the advantages of both OPO and OPA quantum optical devices and opens another avenue for preparation and homodyne detection of high quality bright entangled light with a large wavelength difference.
We experimentally demonstrated that the quantum correlations of amplitude and phase quadratures between signal and idler beams produced from a non-degenerate optical parametric amplifier (NOPA) can be significantly improved by using a mode cleaner in the pump field and reducing the phase fluctuations in phase locking systems. Based on the two technical improvements the quantum entanglement measured with a two-mode homodyne detector is enhanced from approximately 4 dB to approximately 6 dB below the quantum noise limit using the same NOPA and nonlinear crystal.