IEEE Sensors Journal

A Low-Noise, Large-Dynamic-Range-Enhanced Amplifier Based on JFET Buffering Input and JFET Bootstrap Structure

Haijun J. Zhou, Wenzhe Wang, Chaoyong Chen, Yaohui Zheng

Published Nov 20, 2014• 36 citations
Publisher

Abstract

We design a low-noise, large-dynamic-range amplifier based on transimpedance amplifier (TIA) for detecting shot noise of 1064-nm laser in quantum optical experiments. Compared with a single-junction field-effect transistor (JFET) buffered TIA, the electronic noise is effectively 2.8 dB suppressed at the analysis of 2 MHz, and 4 dB suppressed at 4 MHz by means of a JFET bootstrap structure. Under the transimpedance gain of 200 kΩ and 0.5 pF, the measured shot noise at the injected laser power of 51 μW is 12.5 dB above the electronic noise at 2 MHz, and 9.8 dB at 4 MHz. With adjustment of bias condition of the bootstrap structure and application of a L-C (inductance and capacitance) structure, the dynamic range is largely boosted from the original 1.52 to 11.22 mW. The amplifier meets the requirement of SNR for Bell-state detection in quantum optical experiments.

DOI
10.1109/jsen.2014.2371893

Related papers

A low-noise, high-gain, and large-dynamic-range photodetector based on a JFET and a charge amplifier

Jinrong Wang, Shuange Wu, Chengdong Mi +2 more

We demonstrate a low-noise, high-gain, and large-dynamic-range photodetector (PD) based on a junction field-effect transistor (JFET) and a charge amplifier for the measurement of quantum noise in Bell-state detection (BSD). Particular photodiode junction capacitance allows the silicon N-channel JFET 2sk152 to be matched to the noise requirement for charge amplifier A250. The electronic noise of the PD is effectively suppressed and the signal-to-noise ratio (SNR) is up to 15 dB at the analysis frequency of 2.75 MHz for a coherent laser power of 50.08 µW. By combining of the inductor and capacitance, the alternating current (AC) and direct current (DC) branches of the PD can operate linearly in a dynamic range from 25.06 µW to 17.50 mW. The PD can completely meet the requirements of SNR and dynamic range for BSD in quantum optics experiments.

Frontiers of Information Technology & Electronic Engineering•Dec 27, 2023•6 citations

An ultra-sensitive balanced detector with low noise for continuous-variable quantum key distribution

Qi-Ming Lu, Qi Shen, Yuan Cao +2 more

A well-balanced detector with high sensitivity and low noise is presented in this paper. The two-stage amplification structure is used to increase electronic gain while keeping an effective bandwidth of about 70 MHz. In order to further reduce electronic noise, a junction field-effect transistor(JFET) is connected between photodiodes and transimpedance amplifier to reduce the impact of amplifier leakage current. Benefit from these designs, the root-mean-square(RMS) of noise voltage is about 6 mV with a gain of 3.2E5 V/W, and it means an ultra-low noise equivalent power density of 2.2E-12 W/rtHz, only half of common low-noise commercial detectors. In addition, two photodiodes in similar frequency response are selected for detector and make the common mode rejection ratio(CMRR) of detector reached 53 dB, about 13 dB higher than commercial detectors. Further tests indicate that 16.8 dB shot-noise to electronic-noise ratio is measured in our detector, which is better than most high speed balanced detectors.

arXiv:1806.03394•Jun 9, 2018•2 citations

Stabilization improvement of the squeezed optical fields using a high signal-to-noise ratio bootstrap photodetector

Xiaoli Wang, Liang Wu, Shaocong Liang +6 more

High-precision cavity locking is crucial for squeezing optical fields. Here, a bootstrapped low-noise photodetector is utilized in the generation process of the squeezed state of light. This process is based on a combination of a modified trans-impedance amplifier (TIA) circuit and a two-stage bootstrap amplifier circuit. This not only achieves high-precision and long-term stable locking of the optical cavity, but it also improves the degree to which the light field is squeezed. The experiment results show that the detector has a high signal-to-noise ratio (SNR) of 26.7 dB at the analysis frequency of 3 MHz when measuring the shot noise with an injection optical power of 800 µW, and the equivalent optical power noise level is lower than 2.4 pW/Hz in the frequency range of 1-30 MHz. Moreover, the squeezing degree of the quadrature amplitude squeezed state light field can be improved by more than 34.9% when the detector is used for optical cavity locking. The photodetector is useful in continuous variable (CV) quantum information research.

Optics Express•Dec 5, 2022•5 citations

Detection of 13.8 dB squeezed vacuum states by optimizing the interference efficiency and gain of balanced homodyne detection

Xiaocong Sun, Yajun Wang, Long Tian +2 more

Squeezed states belong to the most prominent non-classical resources. They have compelling applications in precise measurement, quantum computation, and detection. Here, we report on the direct measurement of 13.8 dB squeezed vacuum states by improving the interference efficiency and gain of balanced homodyne detection. By employing an auxiliary laser beam, the homodyne visibility is increased to 99.8%. The equivalent loss of the electronic noise is reduced to 0.05% by integrating a junction field-effect transistor (JFET) buffering input and another JFET bootstrap structure in the balanced homodyne detector.

Chinese Optics Letters•Jan 1, 2019•26 citations

Design of low-noise photodetector with a bandwidth of 130 MHz based on transimpedance amplification circuit

Jiliang Qin, Zhihui Yan, Meiru Huo +2 more

A low-noise photodetector is a basic tool for the research of quantum information processing.We present a specially designed low-noise photoelectric detector with a bandwidth of 130 MHz, using a transimpedance amplification circuit.Based on the detailed calculation of the dependence on each parameter of the detector, a useful method of how to design a low-noise and broadband photodetector is provided.When the optical power is between 1.0 and 16 mW, the photodetector has a good linear response to the injected light.Its electronics noise power is below -77 dBm, which is within the whole bandwidth.When the incident light power is 2 mW, the output noise powers are 10.0, 8.0, and 6.0 dB higher than the corresponding electronics noise within the bandwidth of 1-50, 50-90, and 90-130 MHz, respectively, which is in good agreement with the theoretical prediction.Thus, this photoelectric detector could have good application prospects in quantum communication and an optical cavity locking system.

Chinese Optics Letters•Jan 1, 2016•11 citations

Large-area low-noise resonant photodetector for high-sensitivity stimulated Raman scattering spectroscopy and imaging

Wenhao Yu, Haojie Zhang, Jin Bao Guo +1 more

We report a low-noise compensated tuned amplifier (cTAMP) architecture optimized for large-area photodiodes in stimulated Raman scattering (SRS) detection. By integrating a tunable RLC feedback network with a matching compensation inductor, the design simultaneously achieves resonance enhancement and amplifier stability despite the high junction capacitance of a 10 × 10 mm 2 photodiode. As a proof of concept, a detector configured for 20 MHz center frequency and 1 MHz bandwidth exhibits an output-referred noise floor of 31 nV / Hz , enabling shot-noise-limited linear operation from 0.1 mW up to 36 mW optical power under ∼50 μs time constant in the near-IR region. This wide dynamic range and low noise performance allow faithful characterization of high-power squeezed states that saturate conventional detectors, as verified in photon-number squeezing experiments. In addition, the detector facilitates biocompatible ultrafast SRS microscopy with milliwatt-level excitation, supporting hyperspectral live cell imaging without compromising sensitivity. These results establish the cTAMP-based detector as a versatile platform for high-sensitivity quantum optics and biomedical imaging, with potential for extension to other modulation-based optical measurements.

Optics Express•Dec 18, 2025•0 citations
We design a low-noise, large-dynamic-range amplifier based on transimpedance amplifier (TIA) for detecting shot noise of 1064-nm laser in quantum optical experiments. Compared with a single-junction field-effect transistor (JFET) buffered TIA, the electronic noise is effectively 2.8 dB suppressed at the analysis of 2 MHz, and 4 dB suppressed at 4 MHz by means of a JFET bootstrap structure. Under the transimpedance gain of 200 kΩ and 0.5 pF, the measured shot noise at the injected laser power of 51 μW is 12.5 dB above the electronic noise at 2 MHz, and 9.8 dB at 4 MHz. With adjustment of bias condition of the bootstrap structure and application of a L-C (inductance and capacitance) structure, the dynamic range is largely boosted from the original 1.52 to 11.22 mW. The amplifier meets the requirement of SNR for Bell-state detection in quantum optical experiments.
We demonstrate a low-noise, high-gain, and large-dynamic-range photodetector (PD) based on a junction field-effect transistor (JFET) and a charge amplifier for the measurement of quantum noise in Bell-state detection (BSD). Particular photodiode junction capacitance allows the silicon N-channel JFET 2sk152 to be matched to the noise requirement for charge amplifier A250. The electronic noise of the PD is effectively suppressed and the signal-to-noise ratio (SNR) is up to 15 dB at the analysis frequency of 2.75 MHz for a coherent laser power of 50.08 µW. By combining of the inductor and capacitance, the alternating current (AC) and direct current (DC) branches of the PD can operate linearly in a dynamic range from 25.06 µW to 17.50 mW. The PD can completely meet the requirements of SNR and dynamic range for BSD in quantum optics experiments.
A well-balanced detector with high sensitivity and low noise is presented in this paper. The two-stage amplification structure is used to increase electronic gain while keeping an effective bandwidth of about 70 MHz. In order to further reduce electronic noise, a junction field-effect transistor(JFET) is connected between photodiodes and transimpedance amplifier to reduce the impact of amplifier leakage current. Benefit from these designs, the root-mean-square(RMS) of noise voltage is about 6 mV with a gain of 3.2E5 V/W, and it means an ultra-low noise equivalent power density of 2.2E-12 W/rtHz, only half of common low-noise commercial detectors. In addition, two photodiodes in similar frequency response are selected for detector and make the common mode rejection ratio(CMRR) of detector reached 53 dB, about 13 dB higher than commercial detectors. Further tests indicate that 16.8 dB shot-noise to electronic-noise ratio is measured in our detector, which is better than most high speed balanced detectors.
High-precision cavity locking is crucial for squeezing optical fields. Here, a bootstrapped low-noise photodetector is utilized in the generation process of the squeezed state of light. This process is based on a combination of a modified trans-impedance amplifier (TIA) circuit and a two-stage bootstrap amplifier circuit. This not only achieves high-precision and long-term stable locking of the optical cavity, but it also improves the degree to which the light field is squeezed. The experiment results show that the detector has a high signal-to-noise ratio (SNR) of 26.7 dB at the analysis frequency of 3 MHz when measuring the shot noise with an injection optical power of 800 µW, and the equivalent optical power noise level is lower than 2.4 pW/Hz in the frequency range of 1-30 MHz. Moreover, the squeezing degree of the quadrature amplitude squeezed state light field can be improved by more than 34.9% when the detector is used for optical cavity locking. The photodetector is useful in continuous variable (CV) quantum information research.
Squeezed states belong to the most prominent non-classical resources. They have compelling applications in precise measurement, quantum computation, and detection. Here, we report on the direct measurement of 13.8 dB squeezed vacuum states by improving the interference efficiency and gain of balanced homodyne detection. By employing an auxiliary laser beam, the homodyne visibility is increased to 99.8%. The equivalent loss of the electronic noise is reduced to 0.05% by integrating a junction field-effect transistor (JFET) buffering input and another JFET bootstrap structure in the balanced homodyne detector.
A low-noise photodetector is a basic tool for the research of quantum information processing.We present a specially designed low-noise photoelectric detector with a bandwidth of 130 MHz, using a transimpedance amplification circuit.Based on the detailed calculation of the dependence on each parameter of the detector, a useful method of how to design a low-noise and broadband photodetector is provided.When the optical power is between 1.0 and 16 mW, the photodetector has a good linear response to the injected light.Its electronics noise power is below -77 dBm, which is within the whole bandwidth.When the incident light power is 2 mW, the output noise powers are 10.0, 8.0, and 6.0 dB higher than the corresponding electronics noise within the bandwidth of 1-50, 50-90, and 90-130 MHz, respectively, which is in good agreement with the theoretical prediction.Thus, this photoelectric detector could have good application prospects in quantum communication and an optical cavity locking system.
We report a low-noise compensated tuned amplifier (cTAMP) architecture optimized for large-area photodiodes in stimulated Raman scattering (SRS) detection. By integrating a tunable RLC feedback network with a matching compensation inductor, the design simultaneously achieves resonance enhancement and amplifier stability despite the high junction capacitance of a 10 × 10 mm 2 photodiode. As a proof of concept, a detector configured for 20 MHz center frequency and 1 MHz bandwidth exhibits an output-referred noise floor of 31 nV / Hz , enabling shot-noise-limited linear operation from 0.1 mW up to 36 mW optical power under ∼50 μs time constant in the near-IR region. This wide dynamic range and low noise performance allow faithful characterization of high-power squeezed states that saturate conventional detectors, as verified in photon-number squeezing experiments. In addition, the detector facilitates biocompatible ultrafast SRS microscopy with milliwatt-level excitation, supporting hyperspectral live cell imaging without compromising sensitivity. These results establish the cTAMP-based detector as a versatile platform for high-sensitivity quantum optics and biomedical imaging, with potential for extension to other modulation-based optical measurements.