Physical Review A

Decrease in the visibility of the interference fringes in a cold-atom accelerometer

James Stickney, Alex A. Zozulya

Published Jun 17, 2004• 1 citation
Publisher

Abstract

We analyze operation of a cold-atom accelerometer, an interferometric device which measures linear accelerations. We develop an analytic model that predicts a decrease in the visibility of the interference fringes and also their shift caused by the acceleration of the device. This effect places an upper limit on the maximum value of acceleration that can be measured for given parameters of the confining potential and the measurement cycle time.

DOI
10.1103/physreva.69.063611

Related papers

An atom interferometer for measuring horizontal accelerations

Jimmy Stammers

Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.

•Nov 1, 2018•6 citations

Impact of rotation on a cold-atom interferometer and compensation strategy

Noémie Marquet, Yannick Bidel, Malo Cadoret +8 more

Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered in Earth orbiting satellites in the perspective of future space gravity missions on-boarding a cold atom accelerometer. We study in this context the impact of rotation on the phase shift and contrast of an atom interferometer and investigate mitigation strategies. An analytical model is derived and compared to experimental demonstrations carried out using an original setup in which the well-controlled proof-mass of a space electrostatic accelerometer is used as the retro-reflection mirror of a cold atom gravimeter. By properly counter-rotating the electrostatic proof-mass, we demonstrate for instance the possibility of recovering the interferometer contrast, otherwise equal to zero, to a level better than 90%, in both cases of constant angular velocities or in presence of angular accelerations. Our results demonstrate the possibility to perform high performance inertial measurements with a cold atom interferometer in a challenging environments.

arXiv:2510.14755•Physical Review A•Jan 27, 2026•2 citations

An Accelerometer Using an On-Chip Cold Atom Interferometer

Soizic Hello, Alexandre Mersch, B. Wirtschafter +3 more

We present an on-chip cold atom inertial sensor based on a Ramsey sequence configured to measure acceleration. Cold atom interferometers are of great interest due to their excellent stability and sensitivity to inertial effects. Atom chips enable a drastic size reduction of the sensor by trapping atoms during the whole measurement. During the interferometry sequence, we create a superposition of two atomic states and spatially split them, rendering the device sensitive to acceleration. We give the current noise budget at Allan deviation first point for our on-chip accelerometer.

IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)•May 4, 2025•0 citations

Rejection of wavefront aberrations in an atomic gradiometer

Louis Pagot, Sébastien Merlet, Leonid A Sidorenkov +1 more

One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.

physics.atom-phCross-listedarXiv:2511.07013•Optics Express•Nov 11, 2025•0 citations

COLD ATOM GYROSCOPE FOR PRECISION MEASUREMENTS

Florence Leduc, David Holleville, J. Fils +5 more

We report preliminary results obtained with our atomic gyroscope. The first measurements have been realized in a configuration which enables an estimation of the limit of the signal to noise and the effect of most of the systematics. We present the first interferometric fringes in the usual configuration sensitive to rotation and acceleration.

Laser Spectroscopy•Feb 1, 2004•3 citations

Phase stabilization of laser beams in a cold atom accelerometer

Nicole Byrne

A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.

•Jan 1, 2014•0 citations
We analyze operation of a cold-atom accelerometer, an interferometric device which measures linear accelerations. We develop an analytic model that predicts a decrease in the visibility of the interference fringes and also their shift caused by the acceleration of the device. This effect places an upper limit on the maximum value of acceleration that can be measured for given parameters of the confining potential and the measurement cycle time.
Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.
Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered in Earth orbiting satellites in the perspective of future space gravity missions on-boarding a cold atom accelerometer. We study in this context the impact of rotation on the phase shift and contrast of an atom interferometer and investigate mitigation strategies. An analytical model is derived and compared to experimental demonstrations carried out using an original setup in which the well-controlled proof-mass of a space electrostatic accelerometer is used as the retro-reflection mirror of a cold atom gravimeter. By properly counter-rotating the electrostatic proof-mass, we demonstrate for instance the possibility of recovering the interferometer contrast, otherwise equal to zero, to a level better than 90%, in both cases of constant angular velocities or in presence of angular accelerations. Our results demonstrate the possibility to perform high performance inertial measurements with a cold atom interferometer in a challenging environments.
We present an on-chip cold atom inertial sensor based on a Ramsey sequence configured to measure acceleration. Cold atom interferometers are of great interest due to their excellent stability and sensitivity to inertial effects. Atom chips enable a drastic size reduction of the sensor by trapping atoms during the whole measurement. During the interferometry sequence, we create a superposition of two atomic states and spatially split them, rendering the device sensitive to acceleration. We give the current noise budget at Allan deviation first point for our on-chip accelerometer.
One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.
A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.