Abstract

We demonstrate a sensitive method of charge detection based on radio-frequency readout of the Josephson inductance of a superconducting single-electron transistor. Charge sensitivity 1.4 x 10(-4) e/square root Hz, limited by a preamplifier, is achieved in an operation mode which takes advantage of the nonlinearity of the Josephson potential. Owing to reactive readout, our setup has more than 2 orders of magnitude lower dissipation than the existing method of radio-frequency electrometry. With an optimized sample, we expect uncoupled energy sensitivity below variant Planck's over h in the same experimental scheme.

DOI
10.1103/physrevlett.93.066805

Related papers

The Radio-Frequency Single-Electron Transistor (RF-SET): A Fast and Ultrasensitive Electrometer

R. J. Schoelkopf, Paula Wahlgren, A. A. Kozhevnikov +2 more

A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.

Science•May 22, 1998•770 citations

Single-electron transistor as a radio-frequency mixer

Robert G. Knobel, Christopher S. Yung, Andrew N. Cleland

We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.

Applied Physics Letters•Jul 15, 2002•56 citations

Charge sensitivity of the inductive single-electron transistor

Mika A. Sillanpää, Leif Roschier, Pertti Juhani Hakonen

We calculate the charge sensitivity of a recently demonstrated device where the Josephson inductance of a single Cooper-pair transistor is measured. We find that the intrinsic limit to detector performance is set by oscillator quantum noise. Sensitivity better than 10−6e∕Hz is possible with a high Q value ∼103, or using a superconducting quantum interference device amplifier. The model is compared to experiment, where charge sensitivity 3×10−5e∕Hz and bandwidth 100 MHz are achieved.

arXiv:cond-mat/0504122•Applied Physics Letters•Aug 19, 2005•8 citations

An ultrasensitive radio-frequency single-electron transistor working up to 4.2 K

Henrik Brenning, Sergey G. Kafanov, T. Duty +2 more

We present the measurement of a radio-frequency single-electron transistor that displays a very high charge sensitivity of 1.9 μe∕Hz at 4.2 K. At 40 mK, the charge sensitivity is 0.9 and 1.0 μe∕Hz in the superconducting and normal state, respectively. The sensitivity was measured as a function of radio frequency amplitude at three different temperatures; 40 mK, 1.8, and 4.2 K.

arXiv:cond-mat/0602518•Journal of Applied Physics•Dec 1, 2006•77 citations

On-chip matching networks for radio-frequency single-electron transistors

W. W. Xue, B. Davis, Feng Pan +4 more

In this letter, the authors describe operation of a radio-frequency superconducting single electron transistor (rf-SSET) with an on-chip superconducting LC matching network consisting of a spiral inductor L and its capacitance to ground Cp. The superconducting network has a lower Cp and gives a better matching for the rf-SSET than does a commercial chip inductor. Moreover, the superconducting network has negligibly low dissipation, leading to sensitive response to changes in the rf-SSET impedance. The charge sensitivity δq=2.4×10−6e∕Hz in the subgap region and energy sensitivity δε=1.9ℏ indicate that the rf-SSET is operating in the vicinity of the shot noise limit.

arXiv:0708.1007•Applied Physics Letters•Aug 27, 2007•14 citations

A Superconducting Phase Transition Single-Electron Transistor

Gorka Aizpurua-Iraola, Thomas H. Swift, Felix-Ekkehard von Horstig +6 more

Quantum computers require fast and accurate methods for qubit state detection. Phase-transition sensors exploit the abrupt change between two physical states of a material to achieve enhanced sensitivity and have enabled advanced detectors for quantum technologies, such as superconducting nanowire single-photon detectors. However, this sensing principle has not yet been applied to semiconductor spin qubits. Here, we demonstrate a superconducting phase-transition radio-frequency single-electron transistor (PTSET), a charge sensor for semiconductor spin qubits whose response is enhanced by a superconducting-to-normal phase transition. The transition is engineered by linking the sensor current to a low-critical-current, high-kinetic-inductance inductor integrated into the radio-frequency matching network. We demonstrate improvements in sensitivity of one and two orders of magnitude over conventional rfSETs in the large- and small-signal regimes, respectively. Our results establish phase-transition sensing as a route towards ultrasensitive, integrated charge sensors for semiconductor quantum computing and point to broader applications, including cryogenic photon detection for radio astronomy.

quant-pharXiv:2608.27045•Aug 28, 2026•1 citation
We demonstrate a sensitive method of charge detection based on radio-frequency readout of the Josephson inductance of a superconducting single-electron transistor. Charge sensitivity 1.4 x 10(-4) e/square root Hz, limited by a preamplifier, is achieved in an operation mode which takes advantage of the nonlinearity of the Josephson potential. Owing to reactive readout, our setup has more than 2 orders of magnitude lower dissipation than the existing method of radio-frequency electrometry. With an optimized sample, we expect uncoupled energy sensitivity below variant Planck's over h in the same experimental scheme.
A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.
We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.
In this letter, the authors describe operation of a radio-frequency superconducting single electron transistor (rf-SSET) with an on-chip superconducting LC matching network consisting of a spiral inductor L and its capacitance to ground Cp. The superconducting network has a lower Cp and gives a better matching for the rf-SSET than does a commercial chip inductor. Moreover, the superconducting network has negligibly low dissipation, leading to sensitive response to changes in the rf-SSET impedance. The charge sensitivity δq=2.4×10−6e∕Hz in the subgap region and energy sensitivity δε=1.9ℏ indicate that the rf-SSET is operating in the vicinity of the shot noise limit.
Quantum computers require fast and accurate methods for qubit state detection. Phase-transition sensors exploit the abrupt change between two physical states of a material to achieve enhanced sensitivity and have enabled advanced detectors for quantum technologies, such as superconducting nanowire single-photon detectors. However, this sensing principle has not yet been applied to semiconductor spin qubits. Here, we demonstrate a superconducting phase-transition radio-frequency single-electron transistor (PTSET), a charge sensor for semiconductor spin qubits whose response is enhanced by a superconducting-to-normal phase transition. The transition is engineered by linking the sensor current to a low-critical-current, high-kinetic-inductance inductor integrated into the radio-frequency matching network. We demonstrate improvements in sensitivity of one and two orders of magnitude over conventional rfSETs in the large- and small-signal regimes, respectively. Our results establish phase-transition sensing as a route towards ultrasensitive, integrated charge sensors for semiconductor quantum computing and point to broader applications, including cryogenic photon detection for radio astronomy.