Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

New Journal of Physics

The measurement of a single-mode thermal field with a microwave cavity parametric amplifier

C. Braggio, G. Carugno, F. Della Valle, Giuseppe Galeazzi, Augusto Lombardi, G. Ruoso, Dino Zanello

Published Jan 18, 2013• 8 citations
Publisher

Abstract

In this paper, we present the experimental study of a single-mode thermal field carried out using a microwave parametric amplifier tuned at 1.5 GHz and working at room temperature. The parametric amplifier is based on a variable capacitance diode placed inside a microwave resonant cavity. The measured distribution of the thermal photons inside the resonator follows the expected Bose–Einstein distribution probability.

DOI
10.1088/1367-2630/15/1/013044

Related papers

Experimental study of microwave photon statistics under parametric amplification from a single-mode thermal state in a cavity

Giuseppe Galeazzi, Augusto Lombardi, G. Ruoso +5 more

In this paper we present theoretical and experimental studies of the modifications of the thermal spectrum inside a microwave resonator due to a parametric amplification process. Both the degenerate and nondegenerate amplifiers are discussed. Theoretical calculations are compared with measurements performed with a microwave cavity parametric amplifier.

Physical Review A•Nov 6, 2013•5 citations

Low-noise microwave parametric amplifier based on self-heated nonlinear impedance with subnanosecond thermal response

Michael Will, Mohammad Tasnimul Haque, Yuvraj Chaudhry +2 more

Low-noise amplifiers are of great significance in the field of quantum technologies. We study a thermally driven parametric amplifier based on a superconductor-insulator-graphene-insulator-superconductor ($S$-$I$-$G$-$I$-$S$) junction coupled to a superconducting microwave cavity. The strong nonlinearity in the temperature dependence of our device leads to thermal self-modulation that produces impedance oscillations at frequencies around twice the angular cavity resonance frequency ${\ensuremath{\omega}}_{\mathrm{r}}$. In particular, reactance modulation of the effective capacitance yields a gain of 18.6 dB over a frequency span of 125 kHz with a minimum noise temperature of ${T}_{\mathrm{N}}=1.4\phantom{\rule{0.2em}{0ex}}\mathrm{K}$. Our theoretical modeling gives insight into the exact mixing processes, confirmation of the electron-phonon coupling parameter and possible improvements of the studied system.

arXiv:2408.11807•Physical Review Applied•Jan 17, 2025•0 citations

Parametric Microwave Amplification using a Tunable Superconducting Resonator

C. W. Sandbo Chang

In this Master thesis, I present a theoretical description and experimental measurements of a tunable microwave resonator operated as a parametric amplifier. Superconducting parametric amplifiers have attracted great interest in recent years as it has been demonstrated that they can operate with a noise performance at the standard quantum limit. \nParametric amplification is achieved in the devices by modulating the electrical length of the resonator at twice the resonance frequency. The device measured in this thesis consists of a quarter-wavelength microwave resonator fabricated in a thin-film aluminum coplanar waveguide geometry. With a termination to ground through a Superconducting Quantum Interference Device (SQUID), the boundary condition of the resonator becomes sensitive to an applied magnetic field. This enables the tuning of the resonance frequencies, using a DC magnetic field, over a wide frequency range of 670MHz. Similarly, an AC magnetic field then allows for the modulation of the resonator electrical length at microwave frequencies. \nWe characterized the device by first measuring the DC tuning curves of the 2nd and 3rd harmonics of the resonator, around 4 GHz and 6 GHz respectively. We then studied parametric amplification in the device when the electrical length was modulated at approximately twice the resonance frequency of one of the modes. We scanned the pump frequency and pump power over a wide range to study the region in parameters which gives parametric gain. We performed an in-depth parameter sweep over this region, identifying pump parameters that provided maximum gain and maximum system noise improvements compared the following HEMT amplifier. \nWe find that the use of the parametric amplifier can improve the system noise temperature by more than 10 dB compared to a start-of-the-art commercial HEMT amplifier. This implies a performance near the standard quantum limit.

•Sep 2, 2015•0 citations

Hybrid non-degenerate parametric amplifier for a microwave cavity mode and an NV ensemble

Roman Ovsiannikov, Kurt Jacobs, Andrii G. Sotnikov +2 more

We introduce an implementation of a non-degenerate parametric amplifier in which the signal and idler modes, respectively, a microwave mode and an ensemble of spins (e.g., nitrogen-vacancy centers in diamond), are operated in their linear regime. This paramp, which amplifies signals in both parts at room and cryogenic temperatures, can be used to generate both the two-mode and single-mode squeezing of either system. It requires merely modulating the frequency of the spin ensemble at the sum of the cavity and spin frequencies (providing the classical pump) with the two systems sufficiently detuned. This effect is remarkable given that modulating a spin ensemble by itself produces neither amplification nor squeezing, unlike modulating an oscillator, and that an off-resonant perturbative analysis would suggest that modulating the spin ensemble merely parametrically drives the cavity mode. With typical cavity parameters including a cavity quality factor~$Q=10^4$, and a 1 GHz modulation amplitude, the microwave signal can be amplified by approximately $18~\mbox{dB}$ in $1.7~\mbox{$μ$s}$, with a resonant bandwidth of about $0.5~\mbox{MHz}$. At $10~\mbox{mK}$ with the same modulation amplitude and a cavity and spin $Q=5\times 10^4$ it generates approximately $5~\mbox{dB}$ of squeezing. We also examine the experimental requirements for implementation.

quant-pharXiv:2601.03407•Jan 8, 2026•3 citations

Photocount statistics of the Josephson parametric amplifier

Jean Olivier Simoneau, Stéphane Virally, Christian Lupien +1 more

Parametric amplifiers are known to squeeze the vacuum state of the electromagnetic field, thus the statistics of the photocounts at their output should be that of squeezed vacuum. However, several theoretical works predict a very different statistical distribution. We have measured the photocount statistics of a Josephson parametric amplifier and recover the expected squeezed vacuum statistics. We explain this discrepancy by showing theoretically how the photocount statistics is dictated by the detection process. Namely, most experiments will naturally measure a single mode of the electromagnetic field, while the aforementioned theoretical works implicitly describe massively multimode detection.

arXiv:2010.03014•Physical Review Research•Mar 4, 2022•4 citations

Observation of thermal noise squeezing via a Josephson parametric amplifier

B. Yurke, P. G. Kaminsky, Ronald Earle Miller +4 more

We are engaged in a research effort to generate squeezed microwaves at K-band frequencies (18–26.5 GHz) using a Josephson parametric amplifier. As a milestone in this effort we have demonstrated 4-K thermal noise squeezing at 19 GHz. A superconductor–insulator–superconductor (SIS) mixer was employed as the detector. The parametric amplifier and SIS mixer were both cooled to 4.2 K, and care was taken using cold attenuators and isolators to make negligible the amount of room-temperature microwave noise coupled into the cryostat.

Annual Meeting Optical Society of America•Jan 1, 1987•0 citations
In this paper, we present the experimental study of a single-mode thermal field carried out using a microwave parametric amplifier tuned at 1.5 GHz and working at room temperature. The parametric amplifier is based on a variable capacitance diode placed inside a microwave resonant cavity. The measured distribution of the thermal photons inside the resonator follows the expected Bose–Einstein distribution probability.
Low-noise amplifiers are of great significance in the field of quantum technologies. We study a thermally driven parametric amplifier based on a superconductor-insulator-graphene-insulator-superconductor (SSS-III-GGG-III-SSS) junction coupled to a superconducting microwave cavity. The strong nonlinearity in the temperature dependence of our device leads to thermal self-modulation that produces impedance oscillations at frequencies around twice the angular cavity resonance frequency ${\ensuremath{\omega}}_{\mathrm{r}}$. In particular, reactance modulation of the effective capacitance yields a gain of 18.6 dB over a frequency span of 125 kHz with a minimum noise temperature of TN=1.4K{T}_{\mathrm{N}}=1.4\phantom{\rule{0.2em}{0ex}}\mathrm{K}TN​=1.4K. Our theoretical modeling gives insight into the exact mixing processes, confirmation of the electron-phonon coupling parameter and possible improvements of the studied system.
In this Master thesis, I present a theoretical description and experimental measurements of a tunable microwave resonator operated as a parametric amplifier. Superconducting parametric amplifiers have attracted great interest in recent years as it has been demonstrated that they can operate with a noise performance at the standard quantum limit. \nParametric amplification is achieved in the devices by modulating the electrical length of the resonator at twice the resonance frequency. The device measured in this thesis consists of a quarter-wavelength microwave resonator fabricated in a thin-film aluminum coplanar waveguide geometry. With a termination to ground through a Superconducting Quantum Interference Device (SQUID), the boundary condition of the resonator becomes sensitive to an applied magnetic field. This enables the tuning of the resonance frequencies, using a DC magnetic field, over a wide frequency range of 670MHz. Similarly, an AC magnetic field then allows for the modulation of the resonator electrical length at microwave frequencies. \nWe characterized the device by first measuring the DC tuning curves of the 2nd and 3rd harmonics of the resonator, around 4 GHz and 6 GHz respectively. We then studied parametric amplification in the device when the electrical length was modulated at approximately twice the resonance frequency of one of the modes. We scanned the pump frequency and pump power over a wide range to study the region in parameters which gives parametric gain. We performed an in-depth parameter sweep over this region, identifying pump parameters that provided maximum gain and maximum system noise improvements compared the following HEMT amplifier. \nWe find that the use of the parametric amplifier can improve the system noise temperature by more than 10 dB compared to a start-of-the-art commercial HEMT amplifier. This implies a performance near the standard quantum limit.
We introduce an implementation of a non-degenerate parametric amplifier in which the signal and idler modes, respectively, a microwave mode and an ensemble of spins (e.g., nitrogen-vacancy centers in diamond), are operated in their linear regime. This paramp, which amplifies signals in both parts at room and cryogenic temperatures, can be used to generate both the two-mode and single-mode squeezing of either system. It requires merely modulating the frequency of the spin ensemble at the sum of the cavity and spin frequencies (providing the classical pump) with the two systems sufficiently detuned. This effect is remarkable given that modulating a spin ensemble by itself produces neither amplification nor squeezing, unlike modulating an oscillator, and that an off-resonant perturbative analysis would suggest that modulating the spin ensemble merely parametrically drives the cavity mode. With typical cavity parameters including a cavity quality factor~Q=104Q=10^4Q=104, and a 1 GHz modulation amplitude, the microwave signal can be amplified by approximately $18~\mbox{dB}$ in $1.7~\mbox{$μ$s}$, with a resonant bandwidth of about $0.5~\mbox{MHz}$. At $10~\mbox{mK}$ with the same modulation amplitude and a cavity and spin Q=5×104Q=5\times 10^4Q=5×104 it generates approximately $5~\mbox{dB}$ of squeezing. We also examine the experimental requirements for implementation.
Parametric amplifiers are known to squeeze the vacuum state of the electromagnetic field, thus the statistics of the photocounts at their output should be that of squeezed vacuum. However, several theoretical works predict a very different statistical distribution. We have measured the photocount statistics of a Josephson parametric amplifier and recover the expected squeezed vacuum statistics. We explain this discrepancy by showing theoretically how the photocount statistics is dictated by the detection process. Namely, most experiments will naturally measure a single mode of the electromagnetic field, while the aforementioned theoretical works implicitly describe massively multimode detection.
We are engaged in a research effort to generate squeezed microwaves at K-band frequencies (18–26.5 GHz) using a Josephson parametric amplifier. As a milestone in this effort we have demonstrated 4-K thermal noise squeezing at 19 GHz. A superconductor–insulator–superconductor (SIS) mixer was employed as the detector. The parametric amplifier and SIS mixer were both cooled to 4.2 K, and care was taken using cold attenuators and isolators to make negligible the amount of room-temperature microwave noise coupled into the cryostat.