Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

A concentrated radioactive beam source for atom cooling and trapping

Jason Maddi, Timothy P. Dinneen, Albert Ghiorso, Harvey Gould

Published May 1, 1996• 0 citations
OpenAlex

Abstract

The authors describe a novel oven to obtain concentrated beams of radioactive atoms. The Orthotropic oven works by ionizing atoms on its interior walls and electrostatically concentrating them on a neutralizer. Once neutralized the atoms can escape from the oven and form a narrow beam. Atoms that fail to escape become ionized again and repeat the cycle. The authors demonstrate the operation of this oven using {sup 221}Fr and compare both the theoretical and experimental efficiency of this source with standard effusive and channeled ovens.

Related papers

An orthotropic source of thermal atoms

Timothy P. Dinneen, Albert Ghiorso, Harvey Gould

A source of thermal atoms that emits 100% of its atoms into a narrow beam with small angular divergence is described. It uses both surface ionization and surface neutralization in conjunction with electric fields to selectively emit a highly directional (orthotropic) beam of neutral atoms. The source can be modulated electronically and lends itself to scanning. This orthotropic source is ideal for the efficient use of rare atomic species, is well suited for atomic clocks, is essential for the efficient delivery of radioactive atoms to optical traps, and has the potential to produce ultrahigh intensity beams of stable atoms.

Review of Scientific Instruments•Mar 1, 1996•25 citations

A new design of a compact strontium cold-atom source

Dongyang Xu

A high-flux compact source of strontium atoms has been designed and built. We have investigated the feasibility of direct trapping of cold atoms from the atomic flux out of a hot oven. Our design uses a two-dimensional magneto-optical trap (MOT) with an additional laser beam that exerts a radiation force that is not counterbalanced to eject atoms (so-called ‘push’ beam), which is known as a 2D+ MOT configuration. This approach has been previously used for sodium, and has been extended to strontium in this work. Laser cooling of strontium typically requires multiple stages: effusion of atoms from an oven to produce an atomic beam, transverse collimation, a Zeeman slower and deflection before finally collecting atoms in a 3D MOT. A 2D+ MOT combines the Zeeman slowing, transverse collimation, and deflection into a single compact stage to provide a high-flux source suitable for applications such as matter-wave interferometry, atomic clocks and experimental studies of degenerate quantum gases. This thesis reports experimental work that has been carried out to develop and test an oven and the associated laser cooling apparatus for producing a source of cold strontium atoms which is straightforward to manufacture. We test the oven up to a temperature of To = 642 °C and measure a peak intensity of 6.8 × 1016 s−1 sr−1 and a flux of 2.9 × 1016 s−1. We typically operate the oven at To = 502 °C, for which the peak intensity and flux are 2.2 × 1015 s−1 sr−1 and 7.5 × 1014 s−1. A multi-channel nozzle made of graphite gives an angular divergence of 0.17 rad (10°) for the atomic beam. Trapping atoms directly from the thermal atomic beam into the MOT gives a maximum loading rate of 7.1 × 1010 s−1, without any laser light to repump atoms into the cooling cycle. We demonstrated a novel frequency stabilising technique for the laser by developing Zeeman-tunable modulation transfer spectroscopy in strontium with an inaccuracy of ±3.5 MHz and a frequency tuning range of 160 MHz. The initial aim of this thesis was to make a compact, high-flux strontium source suitable for quantum technology applications. During the course of this research, we participated in the preparation of a proposal for the construction of a large-scale atom interferometer based on the clock transition in strontium (87Sr) for the exploration of dark matter and gravitational waves (a project known as the Atom Interferometer Observatory and Network, AION). This changed the design requirements towards producing a higher flux (in particular of the isotope 87Sr), with compactness of the source being less important in ∼10 m scale apparatus.

•Jan 1, 2020•0 citations

Atomic beam source for the ultracold focused ion beam setup

Brenda R. J. Jansen

In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further. In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further.

•Jan 1, 2013•0 citations

Effusive Atomic Oven Nozzle Design Using a Microcapillary Array

Ruwan Senaratne, S. Rajagopal, Zachary A. Geiger +3 more

We present a simple and inexpensive design for a multichannel effusive oven nozzle which provides improved atomic beam collimation and thus extended oven lifetimes. Using this design we demonstrate an atomic lithium source suitable for trapped-atom experiments. At a nozzle temperature of 525$^{\circ}$C the collimated atomic beam flux directly after the nozzle is $1.2 \times 10^{14}$ atoms per second with a peak beam intensity greater than $5.0 \times 10^{16}$ atoms per second per steradian. This suggests an oven lifetime of several decades of continuous operation.

•Jul 23, 2014•1 citation

Effusive atomic oven nozzle design using an aligned microcapillary array

Ruwan Senaratne, S. Rajagopal, Zachary A. Geiger +3 more

We present a simple and inexpensive design for a multichannel effusive oven nozzle which provides improved atomic beam collimation and thus extended oven lifetimes. Using this design, we demonstrate an atomic lithium source suitable for trapped-atom experiments. At a nozzle temperature of 525 °C, the collimated atomic beam flux directly after the nozzle is 1.2 × 10(14) atoms/s with a peak beam intensity greater than 5.0 × 10(16) atoms/s/sr. This suggests an oven lifetime of several decades of continuous operation.

arXiv:1407.6391•Review of Scientific Instruments•Feb 1, 2015•48 citations

A simple atomic beam oven with a metal thermal break

Chetan Vishwakarma, Jay Mangaonkar, Kushal Patel +3 more

We report the design and construction of a simple, easy to machine high temperature oven for generating an atomic beam in laser cooling experiments. This design eliminates the problem of thermal isolation of the oven region from the rest of the vacuum system without using a glass or ceramic thermal break. This design simplifies the construction and operation of high temperature ovens for elements having low vapor pressure. We demonstrate the functionality of such a source for strontium (Sr) atoms. We generate a high flux of Sr atoms for use in laser cooling and trapping experiments. The optimization of the design of the metal thermal break is done using a finite element analysis.

arXiv:1810.09090•Review of Scientific Instruments•May 1, 2019•7 citations
The authors describe a novel oven to obtain concentrated beams of radioactive atoms. The Orthotropic oven works by ionizing atoms on its interior walls and electrostatically concentrating them on a neutralizer. Once neutralized the atoms can escape from the oven and form a narrow beam. Atoms that fail to escape become ionized again and repeat the cycle. The authors demonstrate the operation of this oven using {sup 221}Fr and compare both the theoretical and experimental efficiency of this source with standard effusive and channeled ovens.
A source of thermal atoms that emits 100% of its atoms into a narrow beam with small angular divergence is described. It uses both surface ionization and surface neutralization in conjunction with electric fields to selectively emit a highly directional (orthotropic) beam of neutral atoms. The source can be modulated electronically and lends itself to scanning. This orthotropic source is ideal for the efficient use of rare atomic species, is well suited for atomic clocks, is essential for the efficient delivery of radioactive atoms to optical traps, and has the potential to produce ultrahigh intensity beams of stable atoms.
A high-flux compact source of strontium atoms has been designed and built. We have investigated the feasibility of direct trapping of cold atoms from the atomic flux out of a hot oven. Our design uses a two-dimensional magneto-optical trap (MOT) with an additional laser beam that exerts a radiation force that is not counterbalanced to eject atoms (so-called ‘push’ beam), which is known as a 2D+ MOT configuration. This approach has been previously used for sodium, and has been extended to strontium in this work. Laser cooling of strontium typically requires multiple stages: effusion of atoms from an oven to produce an atomic beam, transverse collimation, a Zeeman slower and deflection before finally collecting atoms in a 3D MOT. A 2D+ MOT combines the Zeeman slowing, transverse collimation, and deflection into a single compact stage to provide a high-flux source suitable for applications such as matter-wave interferometry, atomic clocks and experimental studies of degenerate quantum gases. This thesis reports experimental work that has been carried out to develop and test an oven and the associated laser cooling apparatus for producing a source of cold strontium atoms which is straightforward to manufacture. We test the oven up to a temperature of To = 642 °C and measure a peak intensity of 6.8 × 1016 s−1 sr−1 and a flux of 2.9 × 1016 s−1. We typically operate the oven at To = 502 °C, for which the peak intensity and flux are 2.2 × 1015 s−1 sr−1 and 7.5 × 1014 s−1. A multi-channel nozzle made of graphite gives an angular divergence of 0.17 rad (10°) for the atomic beam. Trapping atoms directly from the thermal atomic beam into the MOT gives a maximum loading rate of 7.1 × 1010 s−1, without any laser light to repump atoms into the cooling cycle. We demonstrated a novel frequency stabilising technique for the laser by developing Zeeman-tunable modulation transfer spectroscopy in strontium with an inaccuracy of ±3.5 MHz and a frequency tuning range of 160 MHz. The initial aim of this thesis was to make a compact, high-flux strontium source suitable for quantum technology applications. During the course of this research, we participated in the preparation of a proposal for the construction of a large-scale atom interferometer based on the clock transition in strontium (87Sr) for the exploration of dark matter and gravitational waves (a project known as the Atom Interferometer Observatory and Network, AION). This changed the design requirements towards producing a higher flux (in particular of the isotope 87Sr), with compactness of the source being less important in ∼10 m scale apparatus.
In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further. In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further.
We present a simple and inexpensive design for a multichannel effusive oven nozzle which provides improved atomic beam collimation and thus extended oven lifetimes. Using this design we demonstrate an atomic lithium source suitable for trapped-atom experiments. At a nozzle temperature of 525∘^{\circ}∘C the collimated atomic beam flux directly after the nozzle is 1.2×10141.2 \times 10^{14}1.2×1014 atoms per second with a peak beam intensity greater than 5.0×10165.0 \times 10^{16}5.0×1016 atoms per second per steradian. This suggests an oven lifetime of several decades of continuous operation.
We present a simple and inexpensive design for a multichannel effusive oven nozzle which provides improved atomic beam collimation and thus extended oven lifetimes. Using this design, we demonstrate an atomic lithium source suitable for trapped-atom experiments. At a nozzle temperature of 525 °C, the collimated atomic beam flux directly after the nozzle is 1.2 × 10(14) atoms/s with a peak beam intensity greater than 5.0 × 10(16) atoms/s/sr. This suggests an oven lifetime of several decades of continuous operation.
We report the design and construction of a simple, easy to machine high temperature oven for generating an atomic beam in laser cooling experiments. This design eliminates the problem of thermal isolation of the oven region from the rest of the vacuum system without using a glass or ceramic thermal break. This design simplifies the construction and operation of high temperature ovens for elements having low vapor pressure. We demonstrate the functionality of such a source for strontium (Sr) atoms. We generate a high flux of Sr atoms for use in laser cooling and trapping experiments. The optimization of the design of the metal thermal break is done using a finite element analysis.