Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.00521

Optimal Estimation in Weak Value Amplification with a Position Pointer

Jing-Hui Huang, Jing Zhang, Jian Ge, Lichao Liu, Wang Luo, Xiang-Yun Hu

quant-phSubmitted Oct 31, 2026• Announced Nov 3, 2026• 0 citations
arXivHTMLPDF

Abstract

We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift $Δx$ and measuring the probability change $ΔP_w$ of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift $Δx$, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase $η$ (for $Δx$ measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number $N_r$ (for $ΔP_w$ measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers $P_0$. Generally, measuring the position shift $Δx$ yields higher precision than measuring the probability change $ΔP_w$. At $P_0=0.5$~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of $(5.30\pm0.10)\times10^{-3}$~as, approaching the corresponding photon-statistical Cramér--Rao bound (CRB). At $P_0=50$~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching $(1.80\pm0.06)\times10^{-3}$~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.

AI Summary

Which readout gives the best practical precision in weak-value-amplified birefringence-delay measurements? This paper experimentally compares five observables in a position-pointer WVA setup: CCD fringe displacement and integrated photon number, quadrant-photodiode differential and total signals, and lock-in output phase. Opposite postselections in a double-slit interferometer convert amplified longitudinal phase shifts into transverse fringe displacements. Each observable is calibrated against delays introduced by tilting a half-wave plate, using ten independent linear fits; noise recorded at zero applied delay is converted into delay Allan deviations. At input power $P_0=0.5\,\mathrm{mW}$, CCD fringe displacement gives the lowest minimum Allan deviation, $(5.30\pm0.10)\times10^{-3}\,\mathrm{as}$, compared with a calculated photon-statistical Cramér–Rao bound of $3.48\times10^{-3}\,\mathrm{as}$. At $50\,\mathrm{mW}$, photodiode detection with lock-in demodulation performs best, reaching $(1.80\pm0.06)\times10^{-3}\,\mathrm{as}$ against a quoted bound of $1.38\times10^{-3}\,\mathrm{as}$. The reported error bars quantify calibration-coefficient reproducibility. Position-based readouts generally outperform total-power readouts in these measurements. The comparison concerns this apparatus and its power, noise, and acquisition constraints. CCD operation is limited by saturation; total-power signals are sensitive to laser-power fluctuations; and low-power photodiode signals suffer from detector and digitization resolution. Lock-in detection uses a $1\,\mathrm{s}$ time constant, reducing sensitivity to faster variations. The proposed combination of a high-well-depth, high-speed camera with lock-in processing is not demonstrated.

Little sign of AI-generated textIncrementalOverclaimsMissing comparison

Central claim may not hold: The claimed near-CRB lock-in precision compares a minimum Allan deviation obtained at averaging times above one second with a photon-statistical bound calculated for only 3.33 microseconds, whereas the paper's bound at one second is about 714 times smaller than the reported minimum. The SUM and CCD photon-number delay resolutions at zero delay use finite-range calibration slopes even though the stated postselection-probability model has zero local sensitivity there, invalidating their interpretation as local probability-based delay resolutions.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
5 pages, 3 figures

Related papers

Weak-Value Amplification for Longitudinal Phase Measurements Approaching the Shot-Noise Limit Characterized by Allan Variance

Jing-Hui Huang, Xiang-Yun Hu

We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of $T$ = $0.01-0.1$ s, representing two orders of magnitude variance reduction compared to the $T=300$ s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number $1/N_r$, confirming shot-noise-limited operation with WVA. Furthermore, this $1/N_r$ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime ($>10$ Hz).

quant-pharXiv:2602.17035•Physical Review A•Feb 20, 2026•2 citations

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada +4 more

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

arXiv:2203.15231•Physical Review A•Nov 3, 2022•9 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•13 citations

Implementation of weak measurement amplification with the weak coherent light and optomechanical system

Gang Li, Wen Yang

Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.

arXiv:2104.03561•Journal of Physics B Atomic Molecular and Optical Physics•Jun 9, 2021•2 citations

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

arXiv:2201.13016•Physical Review A•Aug 30, 2022•21 citations
We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift ΔxΔxΔx and measuring the probability change ΔPwΔP_wΔPw​ of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift ΔxΔxΔx, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase ηηη (for ΔxΔxΔx measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number NrN_rNr​ (for ΔPwΔP_wΔPw​ measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers P0P_0P0​. Generally, measuring the position shift ΔxΔxΔx yields higher precision than measuring the probability change ΔPwΔP_wΔPw​. At P0=0.5P_0=0.5P0​=0.5~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of (5.30±0.10)×10−3(5.30\pm0.10)\times10^{-3}(5.30±0.10)×10−3~as, approaching the corresponding photon-statistical Cramér--Rao bound (CRB). At P0=50P_0=50P0​=50~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching (1.80±0.06)×10−3(1.80\pm0.06)\times10^{-3}(1.80±0.06)×10−3~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.
Which readout gives the best practical precision in weak-value-amplified birefringence-delay measurements? This paper experimentally compares five observables in a position-pointer WVA setup: CCD fringe displacement and integrated photon number, quadrant-photodiode differential and total signals, and lock-in output phase. Opposite postselections in a double-slit interferometer convert amplified longitudinal phase shifts into transverse fringe displacements. Each observable is calibrated against delays introduced by tilting a half-wave plate, using ten independent linear fits; noise recorded at zero applied delay is converted into delay Allan deviations.
At input power P0=0.5 mWP_0=0.5\,\mathrm{mW}P0​=0.5mW, CCD fringe displacement gives the lowest minimum Allan deviation, (5.30±0.10)×10−3 as(5.30\pm0.10)\times10^{-3}\,\mathrm{as}(5.30±0.10)×10−3as, compared with a calculated photon-statistical Cramér–Rao bound of 3.48×10−3 as3.48\times10^{-3}\,\mathrm{as}3.48×10−3as. At 50 mW50\,\mathrm{mW}50mW, photodiode detection with lock-in demodulation performs best, reaching (1.80±0.06)×10−3 as(1.80\pm0.06)\times10^{-3}\,\mathrm{as}(1.80±0.06)×10−3as against a quoted bound of 1.38×10−3 as1.38\times10^{-3}\,\mathrm{as}1.38×10−3as. The reported error bars quantify calibration-coefficient reproducibility. Position-based readouts generally outperform total-power readouts in these measurements.
The comparison concerns this apparatus and its power, noise, and acquisition constraints. CCD operation is limited by saturation; total-power signals are sensitive to laser-power fluctuations; and low-power photodiode signals suffer from detector and digitization resolution. Lock-in detection uses a 1 s1\,\mathrm{s}1s time constant, reducing sensitivity to faster variations. The proposed combination of a high-well-depth, high-speed camera with lock-in processing is not demonstrated.
We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of TTT = 0.01−0.10.01-0.10.01−0.1 s, representing two orders of magnitude variance reduction compared to the T=300T=300T=300 s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number 1/Nr1/N_r1/Nr​, confirming shot-noise-limited operation with WVA. Furthermore, this 1/Nr1/N_r1/Nr​ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime (>10>10>10 Hz).
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.