Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.39498

Quantum double lock-in detection via sequential orthogonal quantum mixing

Min Zhuang, Sijie Chen, Jiahao Huang, Chaohong Lee

quant-phSubmitted Sep 30, 2026• Announced Oct 1, 2026• 0 citations
arXivHTMLPDF

Abstract

High-precision measurement of oscillating signal is a ubiquitous issue in fundamental science and a critical task in practical technologies. In quantum metrology, quantum lock-in detection provide an efficient method for measuring such signal. In general, when the initial phase of the oscillating signal is unknown,quantum double lock-in detection can effectively extract complete information about the signal's amplitude, frequency, and initial phase. Conventional quantum double lock-in detection requires two individual quantum interferometry, each of which must undergo state preparation and readout. However, the time for state preparation and readout need not be negligible in practical experiments. In particular, the time for state preparation is longer than the time for sensing. To save experimental resources, it is challenging to achieve quantum double lock-in detection just via a single quantum interferometry while still extracting complete information about the signal's amplitude, frequency, and initial phase. Here, we present a general protocol for achieving a quantum double lock-in detection just via a single quantum interferometry under a sequential orthogonal periodic multipulse sequences. In particular, if the input state is a Greenberger-Horne-Zeilinger state and two interaction-based operations are applied during interferometry, the measurement precisions for frequency, amplitude, and initial phase can both approach the Heisenberg limit. Our study paves a new way for measuring oscillating signals with a single quantum interferometry, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.

AI Summary

The paper asks whether both quadratures of an oscillating signal $S(t)=A\sin(\omega t+\beta)$ can be measured within one interferometric sequence, avoiding separate state-preparation and readout stages for two lock-in measurements. It proposes sequential periodic dynamical-decoupling (PDD) and Carr–Purcell (CP) interrogation blocks, separated by a unitary operation, followed by collective population-difference readout. For two blocks of duration $T=n\tau_m$, resonance occurs at $\tau_m=\pi/\omega$. The accumulated phases then equal $2An\cos\beta/\omega$ and $2An\sin\beta/\omega$. The readout is a sum of two sinusoids as the even pulse number $n$ is varied. Scanning pulse spacing and Fourier-transforming these measurements identifies resonance through a two-peak spectrum; the peak frequencies encode amplitude and initial phase. Thus, “one interferometry” refers to the sequence architecture, while parameter extraction uses repeated measurements across interrogation settings. Analytical calculations and numerical examples compare spin-coherent and GHZ probes. Error-propagation sensitivities scale as $N^{-1/2}$ for spin-coherent states. With GHZ input and two collective interaction-based operations involving $J_z^2$, the reported sensitivities for amplitude, frequency, and initial phase approach $N^{-1}$ scaling; fitted exponents are approximately $-1$, $-1$, and $-0.95$, respectively. The analysis assumes instantaneous sensing pulses and suitable entangling operations. Robustness is examined using toggling-frame cancellation conditions for pulse-angle and detuning errors, and additive Gaussian detection noise. Detection noise of order $\sqrt N$ degrades the finite-size precision scaling toward values between the standard quantum and Heisenberg limits. The study is theoretical and reports no experimental implementation.

Little sign of AI-generated textIncrementalOverclaimsMissing comparisonPossible error

Central claim may not hold: The scalar sensitivity calculations do not establish joint three-parameter Heisenberg scaling, because the stated GHZ readout has a rank-at-most-one Fisher matrix at each fixed setting and the combined scan is not analyzed. The proposed lock-point reconstruction cannot distinguish beta from pi − beta, so it does not establish recovery of an unrestricted initial phase. The GHZ readout formulas require an unstated particle-number restriction, and the prescribed protocol has no population signal for N = 1. The lock-point expectation formulas contain sign inconsistencies, and the GHZ uncertainty formula omits the N-scaled trigonometric arguments required by differentiation. The claimed exact IPR values are invalid for general finite FFT data, and allowed phases can produce a vanishing lock-point signal rather than two spectral peaks.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Related papers

Quantum double lock-in amplifier

Sijie Chen, Min Zhuang, Ruihuang Fang +5 more

Abstract Quantum lock-in amplifiers have been proposed to extract an alternating signal from a strong noise background. However, due to the typical target signal has unknown initial phase, it is challenging to extract complete information about the signal’s amplitude, frequency, and initial phase. Here, we present a general protocol for achieving a quantum double lock-in amplifier by employing two quantum mixers operating under orthogonal pulse sequences. To demonstrate the practical implementation, we discuss the experimental feasibility using a five-level double-Λ coherent population trapping system with Rb atoms. Here, each Λ structure acts as a quantum mixer, and two applied dynamical decoupling sequences serve as orthogonal reference signals. Notably, the system significantly reduces the total measurement time by nearly half and mitigates time-dependent systematic errors compared to conventional two-level systems. Furthermore, our quantum double lock-in amplifier is robust against experimental imperfections. This study establishes a pathway to alternating signal measurement, thereby facilitating the development of practical quantum sensing technologies.

arXiv:2303.07559•Communications Physics•Jun 13, 2024•11 citations

Many-Body Quantum Lock-In Amplifier

Min Zhuang, Jiahao Huang, Chaohong Lee

Achieving high-precision detection of time-dependent signals within noise is a ubiquitous issue in physics and a critical task in metrology.Lock-in amplifiers are detectors that can extract alternating signals within extreme noise via a known carrier frequency.Here we present a protocol for achieving an entanglement-enhanced lock-in amplifier via use of many-body multipulse quantum interferometry.The many-body quantum lock-in amplifier is implemented by application of a periodic multi-π -pulse sequence during the interrogation.Our analytic results show that, by our choosing suitable input states and readout operations, the frequency and amplitude of an unknown alternating field can be simultaneously extracted via population measurements.The lock-in point can be determined via the symmetry of the signal during a single interrogation time or the time-averaged signals for multiple interrogation times.We find that the measurement signal at the lock-in point is independent of the interrogation time.In particular, if we input spin cat states and apply interaction-based readout operations, the measurement precisions for frequency and amplitude can both approach the Heisenberg limit.Moreover, our many-body quantum amplifier is also robust with regard to extreme stochastic noise.Our study paves a new way for measuring time-dependent signals with many-body quantum systems, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.

arXiv:2010.06849•PRX Quantum•Oct 26, 2021•12 citations

Entanglement-enhanced quantum lock-in detection achieving Heisenberg scaling

Jiawei Zhang, M. Zhuang, B. Wang +9 more

Quantum lock-in detection (QLID) is a powerful technique for extracting weak oscillating signals within noise. While entanglement may enhance measurement precision beyond the standard quantum limit (SQL), its integration with QLID is still an experimental challenge. Here we report the first experimental realization of entanglement-enhanced QLID using two trapped 40Ca+ ions. We prepare a Greenberger-Horne-Zeilinger (GHZ) state using a Mϕlmer-Sϕrensen gate and then apply periodic multipulse sequences to execute QLID. Using the GHZ state, the measurement precision approaches the Heisenberg limit (Δω ∝ N−1), surpassing the SQL (Δω ∝ N−1/2) achievable with non-entangled states. Notably, QLID achieves a superior inverse-quadratic temporal scaling (Δω ∝ T−2), exceeding the conventional inverse-linear scaling (Δω ∝ T−1), regardless of entanglement. We further optimize pulse sequences for enhanced robustness against experimental errors. This work establishes a powerful pathway to Heisenberg-limited quantum sensing of weak oscillating signals within noise. Quantum lock-in detection (QLID) is crucial for extracting oscillating signals from noise, while quantum entanglement is vital to surpass the standard of quantum limit in precision measurement. Here, the authors experimentally realise entanglement-enhanced QLID using two trapped ions, achieving frequency measurement precision at the Heisenberg limit and demonstrating an improved inverse-quadratic temporal scaling.

Nature Communications•Dec 6, 2025•3 citations

Sequential Measurements as a Resource in Ancilla-Assisted Quantum Metrology

Koray Mentesoglu, Rahul Trivedi, Sara Mouradian

We present a protocol for simultaneous estimation of both quadratures of a displacement channel on a quantum harmonic oscillator using a single ancilla qubit, without complex state preparation or adaptive control. The qubit is coupled to the quantum harmonic oscillator via controlled displacements of strength $A$ and undergoes $N$ rounds of measurement and reset, while the oscillator coherently accumulates the displacement signal. The non-commuting displacements imprint an order-dependent geometric phase at each round, giving a quantum Fisher information that scales as $\mathcal{O}(A^{2} N^{3})$. Although the measurement record space grows as $2^N$, we show that exact likelihoods for any individual measurement record can be computed in $\mathcal{O}(N^{2})$ time. With this, we show that measurement in the computational basis approximately saturates the quantum bound and maintains the $\mathcal{O}(A^2 N^3)$ scaling. Furthermore, the periodic information extraction makes the protocol robust to decoherence. Our results provide a framework for the design and analysis of sequential measurement in ancilla-assisted protocols.

quant-pharXiv:2605.00287•Physical Review A•May 4, 2026•3 citations

Quantum lock-in measurement of weak alternating signals

Min Zhuang, Sijie Chen, Jiahao Huang +1 more

Abstract The detection of weak time-dependent alternating signals in a strongly noisy background is an important problem in physics and a critical task in metrology. Quantum lock-in amplifier can extract alternating signals within extreme noises by using suitable quantum resources, which has been widely used for magnetic field sensing, vector light shift detection, and force detection. In particular, entanglement-enhanced quantum lock-in amplifier can be realized via many-body quantum interferometry. The many-body lock-in measurement provides a feasible way to achieve high-precision detection of alternating signals, even in noisy environments. In this article, we review general protocol, experiment progresses and potential applications of quantum lock-in measurements.

Quantum Frontiers•Feb 26, 2024•7 citations

An application of quantum metrology: enhanced correlated interferometry

Siva T. Pradyumna

Quantum metrology is a research field that deals with enhancing the resolution or sensing capabilities of a system which is otherwise constrained by classical limits.Improvements in measurements have historically led to new scientific discoveries, the recent example being the gravitational wave detection.Thus, quantum metrology could be an avenue for enabling scientific breakthroughs.In the present thesis, I have reported a first feasibility test of quantum enhanced correlated phase interferometry.A result that, on one other hand, paves the way for developing a new field of quantum metrology and on the other hand, could be applied to the detection of fundamental stochastic noises such as Holographic noise, gravitational wave background or traces of primordial black holes.The experiment was performed injecting two types of quantum states, namely the squeezed states and a twin-beam like state, in a system consisting of two co-located power recycled Michelson interferometers.When two independent squeezed states were injected, we were able in detecting a faint test correlated phase signal with an amplitude several orders of magnitude below the shot noise limited sensitivity of a single interferometer.The joint sensitivity obtained for the double interferometric system with squeezed states injected was (3.21 ± 0.16) × 10 -17 m √ Hz around 13.5 MHz, in a few seconds of measurement time.The second phase of the experiment involved the injection of a bipartite quantum correlated state in the two interferometers.In this case, we have demonstrated a quantum advantage in detecting uncorrelated noise or difference in the two interferometers' signals enabled by the reduction of the noise in the output photo-current subtraction.

•Jun 14, 2019•0 citations
High-precision measurement of oscillating signal is a ubiquitous issue in fundamental science and a critical task in practical technologies. In quantum metrology, quantum lock-in detection provide an efficient method for measuring such signal. In general, when the initial phase of the oscillating signal is unknown,quantum double lock-in detection can effectively extract complete information about the signal's amplitude, frequency, and initial phase. Conventional quantum double lock-in detection requires two individual quantum interferometry, each of which must undergo state preparation and readout. However, the time for state preparation and readout need not be negligible in practical experiments. In particular, the time for state preparation is longer than the time for sensing. To save experimental resources, it is challenging to achieve quantum double lock-in detection just via a single quantum interferometry while still extracting complete information about the signal's amplitude, frequency, and initial phase. Here, we present a general protocol for achieving a quantum double lock-in detection just via a single quantum interferometry under a sequential orthogonal periodic multipulse sequences. In particular, if the input state is a Greenberger-Horne-Zeilinger state and two interaction-based operations are applied during interferometry, the measurement precisions for frequency, amplitude, and initial phase can both approach the Heisenberg limit. Our study paves a new way for measuring oscillating signals with a single quantum interferometry, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.
The paper asks whether both quadratures of an oscillating signal S(t)=Asin⁡(ωt+β)S(t)=A\sin(\omega t+\beta)S(t)=Asin(ωt+β) can be measured within one interferometric sequence, avoiding separate state-preparation and readout stages for two lock-in measurements. It proposes sequential periodic dynamical-decoupling (PDD) and Carr–Purcell (CP) interrogation blocks, separated by a unitary operation, followed by collective population-difference readout.
For two blocks of duration T=nτmT=n\tau_mT=nτm​, resonance occurs at τm=π/ω\tau_m=\pi/\omegaτm​=π/ω. The accumulated phases then equal 2Ancos⁡β/ω2An\cos\beta/\omega2Ancosβ/ω and 2Ansin⁡β/ω2An\sin\beta/\omega2Ansinβ/ω. The readout is a sum of two sinusoids as the even pulse number nnn is varied. Scanning pulse spacing and Fourier-transforming these measurements identifies resonance through a two-peak spectrum; the peak frequencies encode amplitude and initial phase. Thus, “one interferometry” refers to the sequence architecture, while parameter extraction uses repeated measurements across interrogation settings.
Analytical calculations and numerical examples compare spin-coherent and GHZ probes. Error-propagation sensitivities scale as N−1/2N^{-1/2}N−1/2 for spin-coherent states. With GHZ input and two collective interaction-based operations involving Jz2J_z^2Jz2​, the reported sensitivities for amplitude, frequency, and initial phase approach N−1N^{-1}N−1 scaling; fitted exponents are approximately −1-1−1, −1-1−1, and −0.95-0.95−0.95, respectively.
The analysis assumes instantaneous sensing pulses and suitable entangling operations. Robustness is examined using toggling-frame cancellation conditions for pulse-angle and detuning errors, and additive Gaussian detection noise. Detection noise of order N\sqrt NN​ degrades the finite-size precision scaling toward values between the standard quantum and Heisenberg limits. The study is theoretical and reports no experimental implementation.
Abstract Quantum lock-in amplifiers have been proposed to extract an alternating signal from a strong noise background. However, due to the typical target signal has unknown initial phase, it is challenging to extract complete information about the signal’s amplitude, frequency, and initial phase. Here, we present a general protocol for achieving a quantum double lock-in amplifier by employing two quantum mixers operating under orthogonal pulse sequences. To demonstrate the practical implementation, we discuss the experimental feasibility using a five-level double-Λ coherent population trapping system with Rb atoms. Here, each Λ structure acts as a quantum mixer, and two applied dynamical decoupling sequences serve as orthogonal reference signals. Notably, the system significantly reduces the total measurement time by nearly half and mitigates time-dependent systematic errors compared to conventional two-level systems. Furthermore, our quantum double lock-in amplifier is robust against experimental imperfections. This study establishes a pathway to alternating signal measurement, thereby facilitating the development of practical quantum sensing technologies.
Achieving high-precision detection of time-dependent signals within noise is a ubiquitous issue in physics and a critical task in metrology.Lock-in amplifiers are detectors that can extract alternating signals within extreme noise via a known carrier frequency.Here we present a protocol for achieving an entanglement-enhanced lock-in amplifier via use of many-body multipulse quantum interferometry.The many-body quantum lock-in amplifier is implemented by application of a periodic multi-π -pulse sequence during the interrogation.Our analytic results show that, by our choosing suitable input states and readout operations, the frequency and amplitude of an unknown alternating field can be simultaneously extracted via population measurements.The lock-in point can be determined via the symmetry of the signal during a single interrogation time or the time-averaged signals for multiple interrogation times.We find that the measurement signal at the lock-in point is independent of the interrogation time.In particular, if we input spin cat states and apply interaction-based readout operations, the measurement precisions for frequency and amplitude can both approach the Heisenberg limit.Moreover, our many-body quantum amplifier is also robust with regard to extreme stochastic noise.Our study paves a new way for measuring time-dependent signals with many-body quantum systems, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.
Quantum lock-in detection (QLID) is a powerful technique for extracting weak oscillating signals within noise. While entanglement may enhance measurement precision beyond the standard quantum limit (SQL), its integration with QLID is still an experimental challenge. Here we report the first experimental realization of entanglement-enhanced QLID using two trapped 40Ca+ ions. We prepare a Greenberger-Horne-Zeilinger (GHZ) state using a Mϕlmer-Sϕrensen gate and then apply periodic multipulse sequences to execute QLID. Using the GHZ state, the measurement precision approaches the Heisenberg limit (Δω ∝ N−1), surpassing the SQL (Δω ∝ N−1/2) achievable with non-entangled states. Notably, QLID achieves a superior inverse-quadratic temporal scaling (Δω ∝ T−2), exceeding the conventional inverse-linear scaling (Δω ∝ T−1), regardless of entanglement. We further optimize pulse sequences for enhanced robustness against experimental errors. This work establishes a powerful pathway to Heisenberg-limited quantum sensing of weak oscillating signals within noise. Quantum lock-in detection (QLID) is crucial for extracting oscillating signals from noise, while quantum entanglement is vital to surpass the standard of quantum limit in precision measurement. Here, the authors experimentally realise entanglement-enhanced QLID using two trapped ions, achieving frequency measurement precision at the Heisenberg limit and demonstrating an improved inverse-quadratic temporal scaling.
We present a protocol for simultaneous estimation of both quadratures of a displacement channel on a quantum harmonic oscillator using a single ancilla qubit, without complex state preparation or adaptive control. The qubit is coupled to the quantum harmonic oscillator via controlled displacements of strength AAA and undergoes NNN rounds of measurement and reset, while the oscillator coherently accumulates the displacement signal. The non-commuting displacements imprint an order-dependent geometric phase at each round, giving a quantum Fisher information that scales as O(A2N3)\mathcal{O}(A^{2} N^{3})O(A2N3). Although the measurement record space grows as 2N2^N2N, we show that exact likelihoods for any individual measurement record can be computed in O(N2)\mathcal{O}(N^{2})O(N2) time. With this, we show that measurement in the computational basis approximately saturates the quantum bound and maintains the O(A2N3)\mathcal{O}(A^2 N^3)O(A2N3) scaling. Furthermore, the periodic information extraction makes the protocol robust to decoherence. Our results provide a framework for the design and analysis of sequential measurement in ancilla-assisted protocols.
Abstract The detection of weak time-dependent alternating signals in a strongly noisy background is an important problem in physics and a critical task in metrology. Quantum lock-in amplifier can extract alternating signals within extreme noises by using suitable quantum resources, which has been widely used for magnetic field sensing, vector light shift detection, and force detection. In particular, entanglement-enhanced quantum lock-in amplifier can be realized via many-body quantum interferometry. The many-body lock-in measurement provides a feasible way to achieve high-precision detection of alternating signals, even in noisy environments. In this article, we review general protocol, experiment progresses and potential applications of quantum lock-in measurements.
Quantum metrology is a research field that deals with enhancing the resolution or sensing capabilities of a system which is otherwise constrained by classical limits.Improvements in measurements have historically led to new scientific discoveries, the recent example being the gravitational wave detection.Thus, quantum metrology could be an avenue for enabling scientific breakthroughs.In the present thesis, I have reported a first feasibility test of quantum enhanced correlated phase interferometry.A result that, on one other hand, paves the way for developing a new field of quantum metrology and on the other hand, could be applied to the detection of fundamental stochastic noises such as Holographic noise, gravitational wave background or traces of primordial black holes.The experiment was performed injecting two types of quantum states, namely the squeezed states and a twin-beam like state, in a system consisting of two co-located power recycled Michelson interferometers.When two independent squeezed states were injected, we were able in detecting a faint test correlated phase signal with an amplitude several orders of magnitude below the shot noise limited sensitivity of a single interferometer.The joint sensitivity obtained for the double interferometric system with squeezed states injected was (3.21 ± 0.16) × 10 -17 m √ Hz around 13.5 MHz, in a few seconds of measurement time.The second phase of the experiment involved the injection of a bipartite quantum correlated state in the two interferometers.In this case, we have demonstrated a quantum advantage in detecting uncorrelated noise or difference in the two interferometers' signals enabled by the reduction of the noise in the output photo-current subtraction.