Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Frontiers

Quantum lock-in measurement of weak alternating signals

Min Zhuang, Sijie Chen, Jiahao Huang, Chaohong Lee

Published Feb 26, 2024• 7 citations
Publisher

Abstract

Abstract The detection of weak time-dependent alternating signals in a strongly noisy background is an important problem in physics and a critical task in metrology. Quantum lock-in amplifier can extract alternating signals within extreme noises by using suitable quantum resources, which has been widely used for magnetic field sensing, vector light shift detection, and force detection. In particular, entanglement-enhanced quantum lock-in amplifier can be realized via many-body quantum interferometry. The many-body lock-in measurement provides a feasible way to achieve high-precision detection of alternating signals, even in noisy environments. In this article, we review general protocol, experiment progresses and potential applications of quantum lock-in measurements.

DOI
10.1007/s44214-024-00051-7

Related papers

Many-Body Quantum Lock-In Amplifier

Min Zhuang, Jiahao Huang, Chaohong Lee

Achieving high-precision detection of time-dependent signals within noise is a ubiquitous issue in physics and a critical task in metrology.Lock-in amplifiers are detectors that can extract alternating signals within extreme noise via a known carrier frequency.Here we present a protocol for achieving an entanglement-enhanced lock-in amplifier via use of many-body multipulse quantum interferometry.The many-body quantum lock-in amplifier is implemented by application of a periodic multi-π -pulse sequence during the interrogation.Our analytic results show that, by our choosing suitable input states and readout operations, the frequency and amplitude of an unknown alternating field can be simultaneously extracted via population measurements.The lock-in point can be determined via the symmetry of the signal during a single interrogation time or the time-averaged signals for multiple interrogation times.We find that the measurement signal at the lock-in point is independent of the interrogation time.In particular, if we input spin cat states and apply interaction-based readout operations, the measurement precisions for frequency and amplitude can both approach the Heisenberg limit.Moreover, our many-body quantum amplifier is also robust with regard to extreme stochastic noise.Our study paves a new way for measuring time-dependent signals with many-body quantum systems, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.

arXiv:2010.06849•PRX Quantum•Oct 26, 2021•12 citations

Quantum double lock-in detection via sequential orthogonal quantum mixing

Min Zhuang, Sijie Chen, Jiahao Huang +1 more

High-precision measurement of oscillating signal is a ubiquitous issue in fundamental science and a critical task in practical technologies. In quantum metrology, quantum lock-in detection provide an efficient method for measuring such signal. In general, when the initial phase of the oscillating signal is unknown,quantum double lock-in detection can effectively extract complete information about the signal's amplitude, frequency, and initial phase. Conventional quantum double lock-in detection requires two individual quantum interferometry, each of which must undergo state preparation and readout. However, the time for state preparation and readout need not be negligible in practical experiments. In particular, the time for state preparation is longer than the time for sensing. To save experimental resources, it is challenging to achieve quantum double lock-in detection just via a single quantum interferometry while still extracting complete information about the signal's amplitude, frequency, and initial phase. Here, we present a general protocol for achieving a quantum double lock-in detection just via a single quantum interferometry under a sequential orthogonal periodic multipulse sequences. In particular, if the input state is a Greenberger-Horne-Zeilinger state and two interaction-based operations are applied during interferometry, the measurement precisions for frequency, amplitude, and initial phase can both approach the Heisenberg limit. Our study paves a new way for measuring oscillating signals with a single quantum interferometry, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.

quant-pharXiv:2609.39498•Oct 1, 2026•0 citations

Quantum Lock-In Detection via Successive Adiabatic Evolution

Kangze Li, Siqi Chen, Hao Zhang +3 more

In recent years, quantum lock-in detection has emerged as a promising technique to accurately detect weak signals submerged in background noise. However, the signal-to-noise ratio of existing protocols is severely limited by spectral leakage resulting from control operations implemented in pulse form. Here, we propose a general protocol for realizing quantum lock-in detection by employing successive quantum adiabatic evolution. In our protocol, the signal modulation is achieved by adiabatically controlling the time evolution of the quantum probe, which enables the implementation of sinusoidal modulation functions. The realization of sinusoidal-wave modulation substantially mitigates the problem of spectral leakage and facilitates the extraction of the complete characteristics of the target signals. We present a practical implementation scheme of adiabatic quantum lock-in detection based on nitrogen-vacancy centers in diamond, and demonstrate that the proposed protocol possesses strong resilience against experimental imperfections. Our results establish adiabatic quantum lock-in detection as a robust and experimentally accessible approach to detection of weak alternating signals in noisy environments, thus promoting the advance of real-world quantum sensing technologies.

quant-pharXiv:2607.15121•Quantum Science and Technology•Jul 17, 2026•1 citation

High-frequency dual-channel lock-in detection via rapidly oscillating driving

Kangze Li, Xu Zhao, Liantuan Xiao +1 more

Here we propose a general protocol for dual-channel lock-in detection of high-frequency ac signals. We find that the effect of a high-frequency target signal can be modulated through the application of rapidly oscillating driving fields. Based on this mechanism, we develop a quantum dual-channel lock-in detection protocol for high-frequency signals, which not only extends the accessible frequency range of quantum sensing but also enables the simultaneous estimation of the signal amplitude and initial phase. Furthermore, we present a feasible implementation scheme of the protocol based on nitrogen-vacancy centers in diamond. Numerical simulations demonstrate that the proposed protocol can effectively filter out background noise and significantly improve the signal-to-noise ratio. Our results provide a promising approach for realizing noise-resistant detection of weak signals in the high-frequency regime.

quant-pharXiv:2607.17854•Jul 21, 2026•0 citations

AC atom interferometry with quantum lock-in sensing

Jonathan Coslovsky, Gadi Afek, Nir Davidson

This paper describes a technique that allows measurement of very small alternating accelerations. It is based on a quantum version of a lock-in amplifier,1 which filters out spectral components far from the frequency of the measured signal, improving the signal-to-noise ratio of the measurement. As a proof-of-principle, a controlled experiment using microwave radiation is performed, modulating the phase of the control pulses at a given frequency. A strong response at twice the modulation frequency is observed as expected. Preliminary results of measurements taken with Raman control are also presented, in which a controlled modulation of the phase was obtained by modulating a piezoelectric actuator, causing one of the Raman mirrors to vibrate.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 20, 2017•2 citations

Single Spin Detection With Entangled States

Hideaki Hakoshima, Yuichiro Matsuzaki

Single spin detection is one of the important tasks in the field of quantum metrology.Many experiments about the single spin detection has been performed.However, due to the weak magnetic fields from the single spin, a long measurement time is required to achieve a reasonably high signalto-noise ratio.Here, we propose an alternative way to realize rapid and accurate single spin detection with entangled states.While it is known that entanglement can improve the sensitivity to measure globally applied magnetic fields, we investigate a strategy to use the entanglement for detecting spatially inhomogeneous magnetic fields from the target single spin.We show that the entanglement significantly increases the signal to noise ratio for the single spin detection even under the effect of realistic noise.Our results pave the way for practical single spin detection.

International Conference on Solid State Devices and Materials (SSDM)•Sep 4, 2019•0 citations
Abstract The detection of weak time-dependent alternating signals in a strongly noisy background is an important problem in physics and a critical task in metrology. Quantum lock-in amplifier can extract alternating signals within extreme noises by using suitable quantum resources, which has been widely used for magnetic field sensing, vector light shift detection, and force detection. In particular, entanglement-enhanced quantum lock-in amplifier can be realized via many-body quantum interferometry. The many-body lock-in measurement provides a feasible way to achieve high-precision detection of alternating signals, even in noisy environments. In this article, we review general protocol, experiment progresses and potential applications of quantum lock-in measurements.
Achieving high-precision detection of time-dependent signals within noise is a ubiquitous issue in physics and a critical task in metrology.Lock-in amplifiers are detectors that can extract alternating signals within extreme noise via a known carrier frequency.Here we present a protocol for achieving an entanglement-enhanced lock-in amplifier via use of many-body multipulse quantum interferometry.The many-body quantum lock-in amplifier is implemented by application of a periodic multi-π -pulse sequence during the interrogation.Our analytic results show that, by our choosing suitable input states and readout operations, the frequency and amplitude of an unknown alternating field can be simultaneously extracted via population measurements.The lock-in point can be determined via the symmetry of the signal during a single interrogation time or the time-averaged signals for multiple interrogation times.We find that the measurement signal at the lock-in point is independent of the interrogation time.In particular, if we input spin cat states and apply interaction-based readout operations, the measurement precisions for frequency and amplitude can both approach the Heisenberg limit.Moreover, our many-body quantum amplifier is also robust with regard to extreme stochastic noise.Our study paves a new way for measuring time-dependent signals with many-body quantum systems, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.
High-precision measurement of oscillating signal is a ubiquitous issue in fundamental science and a critical task in practical technologies. In quantum metrology, quantum lock-in detection provide an efficient method for measuring such signal. In general, when the initial phase of the oscillating signal is unknown,quantum double lock-in detection can effectively extract complete information about the signal's amplitude, frequency, and initial phase. Conventional quantum double lock-in detection requires two individual quantum interferometry, each of which must undergo state preparation and readout. However, the time for state preparation and readout need not be negligible in practical experiments. In particular, the time for state preparation is longer than the time for sensing. To save experimental resources, it is challenging to achieve quantum double lock-in detection just via a single quantum interferometry while still extracting complete information about the signal's amplitude, frequency, and initial phase. Here, we present a general protocol for achieving a quantum double lock-in detection just via a single quantum interferometry under a sequential orthogonal periodic multipulse sequences. In particular, if the input state is a Greenberger-Horne-Zeilinger state and two interaction-based operations are applied during interferometry, the measurement precisions for frequency, amplitude, and initial phase can both approach the Heisenberg limit. Our study paves a new way for measuring oscillating signals with a single quantum interferometry, and provides a feasible method for achieving Heisenberg-limited detection of alternating signals.
In recent years, quantum lock-in detection has emerged as a promising technique to accurately detect weak signals submerged in background noise. However, the signal-to-noise ratio of existing protocols is severely limited by spectral leakage resulting from control operations implemented in pulse form. Here, we propose a general protocol for realizing quantum lock-in detection by employing successive quantum adiabatic evolution. In our protocol, the signal modulation is achieved by adiabatically controlling the time evolution of the quantum probe, which enables the implementation of sinusoidal modulation functions. The realization of sinusoidal-wave modulation substantially mitigates the problem of spectral leakage and facilitates the extraction of the complete characteristics of the target signals. We present a practical implementation scheme of adiabatic quantum lock-in detection based on nitrogen-vacancy centers in diamond, and demonstrate that the proposed protocol possesses strong resilience against experimental imperfections. Our results establish adiabatic quantum lock-in detection as a robust and experimentally accessible approach to detection of weak alternating signals in noisy environments, thus promoting the advance of real-world quantum sensing technologies.
Here we propose a general protocol for dual-channel lock-in detection of high-frequency ac signals. We find that the effect of a high-frequency target signal can be modulated through the application of rapidly oscillating driving fields. Based on this mechanism, we develop a quantum dual-channel lock-in detection protocol for high-frequency signals, which not only extends the accessible frequency range of quantum sensing but also enables the simultaneous estimation of the signal amplitude and initial phase. Furthermore, we present a feasible implementation scheme of the protocol based on nitrogen-vacancy centers in diamond. Numerical simulations demonstrate that the proposed protocol can effectively filter out background noise and significantly improve the signal-to-noise ratio. Our results provide a promising approach for realizing noise-resistant detection of weak signals in the high-frequency regime.
This paper describes a technique that allows measurement of very small alternating accelerations. It is based on a quantum version of a lock-in amplifier,1 which filters out spectral components far from the frequency of the measured signal, improving the signal-to-noise ratio of the measurement. As a proof-of-principle, a controlled experiment using microwave radiation is performed, modulating the phase of the control pulses at a given frequency. A strong response at twice the modulation frequency is observed as expected. Preliminary results of measurements taken with Raman control are also presented, in which a controlled modulation of the phase was obtained by modulating a piezoelectric actuator, causing one of the Raman mirrors to vibrate.
Single spin detection is one of the important tasks in the field of quantum metrology.Many experiments about the single spin detection has been performed.However, due to the weak magnetic fields from the single spin, a long measurement time is required to achieve a reasonably high signalto-noise ratio.Here, we propose an alternative way to realize rapid and accurate single spin detection with entangled states.While it is known that entanglement can improve the sensitivity to measure globally applied magnetic fields, we investigate a strategy to use the entanglement for detecting spatially inhomogeneous magnetic fields from the target single spin.We show that the entanglement significantly increases the signal to noise ratio for the single spin detection even under the effect of realistic noise.Our results pave the way for practical single spin detection.