Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.22976

Weak Values Beyond the Weak Limit: Measurement-Strength Invariance Under Post-Selection

Cosmin Andrei, Vlatko Vedral

quant-phSubmitted Sep 19, 2026• Announced Sep 22, 2026• 0 citations
arXivHTMLPDF

Abstract

Weak values are conventionally extracted in the limit of vanishing measurement strength. At finite strength, the corresponding post-selected conditional averages generally acquire nonlinear corrections and need not retain their weak value interpretation. Here we identify a class of measurement protocols for which this expectation fails: the conditional value reconstructed from the measuring probe is exactly independent of the probe strength and therefore coincides with the real part of the weak value. We first analyze this phenomenon in the measurement--disturbance protocol introduced by Lund and Wiseman. We then establish conditions under which this invariance persists, showing that it is determined by the interplay between the probe interaction, a subsequent measurement interaction with an ancillary apparatus, and the final post-selection. These results demonstrate that weak coupling, although generally sufficient for accessing weak values, is not always necessary.

AI Summary

The paper asks when a post-selected probe average can equal the real part of a weak value at finite measurement strength, rather than only in the weak-coupling limit. It studies the Lund–Wiseman protocol for reconstructing Ozawa measurement precision and disturbance, then replaces its qubit meters with continuous-variable von Neumann pointers. Exact calculations show that the calibrated conditional probe averages in the ideal qubit protocol are independent of probe strength, both for precision ($Z$ probing followed by a $Z$ apparatus interaction) and disturbance ($X$ probing followed by a $Z$ apparatus interaction). Consequently, the corresponding weak-valued conditional probabilities are recovered without weak probing. For identical coupling observables, this invariance extends to arbitrary finite system dimension when conditioning on the apparatus pointer outcome. For distinct observables, the analysis gives a sufficient condition: apparatus states associated with different initial probe-observable eigenstates must become orthogonal after post-selection. This removes interference contributions from both the conditional-average numerator and denominator. Real initial pointer wavefunctions and mutually unbiased coupling eigenbases ensure this condition for a two-dimensional system post-selected onto a probe-observable eigenstate. The result also extends to direct sums of invariant two-dimensional sectors. An explicit Gaussian-pointer qutrit counterexample shows that mutual unbiasedness alone is insufficient in higher dimensions. The conditions are sufficient, not a general classification. The identified mechanism produces convex combinations of eigenvalues and therefore excludes anomalous weak values. Whether other strength-invariant mechanisms can support anomalous values remains open; the treatment concerns real weak values and restricts initial pointer wavefunctions to be real.

Little sign of AI-generated textIncremental

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
12 pages (10 pages for main text, 2 pages for appendices), 4 figures

Related papers

Transition between weak and strong measurements in the presence of post-selection

Shogo Hanashiro, Holger F. Hofmann

In the weak measurement regime, post-selection can result in the observation of anomalous weak values, seemingly contradicting the eigenvalue statistics observed when the measurement interaction is strong. Here, we investigate the dependence of meter statistics on measurement strength in a post-selected measurement. We find that the meter statistics in the intermediate regime between weak and strong measurements is nearly independent of measurement strength and show that, in this regime, the system performs a measurement of momentum on the meter. Our results show that post-selection is extremely sensitive to the action of the meter on the system, highlighting the difference between the weak measurement regime where this back-action is negligible and the average meter position is a valid measurement result, and the intermediate regime where the meter statistics should not be misinterpreted as a measurement outcome. The transition between weak values and eigenvalues is facilitated by a reversal of the roles of the system and the meter, where the post-selection acts as a readout of information about the meter. The intermediate measurement regime thus reveals that the apparent contradictions between anomalous weak values and eigenvalues originate from the non-classical effects of back-action on the post-selected meter statistics.

quant-pharXiv:2609.04812•Sep 7, 2026•0 citations

The real and imaginary parts of a weak value appearing as back-actions via a post-selection

Kazuhiro Yokota

In a weak measurement the real and imaginary parts of a weak value participate in the shifts of the complementary variables of a pointer. While the real part represents the value of an observable in the limit of zero measurement strength, the imaginary one is regarded as the back-action due to the measurement with a post-selection, which has an influence on the post-selection probability. In this paper I give a case in which a real part could also appear as such a back-action in a post-selection probability on an equal footing with an imaginary one. It is also shown that both of the real and imaginary parts can be inferred by observing the probability in practice, which has an advantage that an additional system of a pointer is not needed.

arXiv:1909.04806•Sep 11, 2019•1 citation

Weak values in a classical theory with an epistemic restriction

Angela Karanjai, Eric G. Cavalcanti, Stephen D. Bartlett +1 more

Weak measurement of a quantum system followed by postselection based on a subsequent strong measurement gives rise to a quantity called the weak value : a complex number for which the interpretation has long been debated. We analyse the procedure of weak measurement and postselection, and the interpretation of the associated weak value, using a theory of classical mechanics supplemented by an epistemic restriction that is known to be operationally equivalent to a subtheory of quantum mechanics. Both the real and imaginary components of the weak value appear as phase space displacements in the postselected expectation values of the measurement device's position and momentum distributions, and we recover the same displacements as in the quantum case by studying the corresponding evolution in our theory of classical mechanics with an epistemic restriction. By using this epistemically restricted theory, we gain insight into the appearance of the weak value as a result of the statistical effects of post selection, and this provides us with an operational interpretation of the weak value, both its real and imaginary parts. We find that the imaginary part of the weak value is a measure of how much postselection biases the mean phase space distribution for a given amount of measurement disturbance. All such biases proportional to the imaginary part of the weak value vanish in the limit where disturbance due to measurement goes to zero. Our analysis also offers intuitive insight into how measurement disturbance can be minimized and the limits of weak measurement.

arXiv:1503.05203•New Journal of Physics•Jul 14, 2015•14 citations

Anomalous Weak Values Without Post-Selection

Alastair A. Abbott, Ralph Silva, Julian Wechs +2 more

A weak measurement performed on a pre- and post-selected quantum system can result in an average value that lies outside of the observable's spectrum. This effect, usually referred to as an ``anomalous weak value'', is generally believed to be possible only when a non-trivial post-selection is performed, i.e., when only a particular subset of the data is considered. Here we show, however, that this is not the case in general: in scenarios in which several weak measurements are sequentially performed, an anomalous weak value can be obtained without post-selection, i.e., without discarding any data. We discuss several questions that this raises about the subtle relation between weak values and pointer positions for sequential weak measurements. Finally, we consider some implications of our results for the problem of distinguishing different causal structures.

arXiv:1805.09364•Quantum•Oct 14, 2019•14 citations

Interference-based weak-value amplification effects in post-selected weak measurement

Yurong Liu, Zhaoxue Li, Yucheng Ye +2 more

Abstract Weak measurement (WM) based on post-selection is a useful tool for precision metrology due to the ability of amplifying weak physical effects. In this paper, we reveal the underlying mechanism of the amplification in the post-selected WM based on the weak-value amplification (WVA) and the almost balanced weak-values amplification (ABWVA) strategies. We find that the amplification stems from the interference between the local oscillator and signal components which are respectively associated with the initial system state and the state disturbance induced by the weak coupling. The magnitude of the amplification is proportional to the interference strength which is dominated by the post-selection and the coupling strength. Furthermore, our theory can perfectly explain the amplification limit in the WVA strategy and the anomalous amplification in the ABWVA strategy.

Laser Physics•Jul 29, 2021•1 citation

Weak value as an indicator of back-action

Riuji Mochizuki

In this study we critically examine some important papers on weak measurement and weak values. We find some insufficiency and mistakes in these papers, and we demonstrate that the real parts of weak values provide the back-action to the post-selection, which is caused by weak measurement. Two examples, a counterfactual statement of Hardy's paradox and experiments that determine the average trajectory of photons passing through double slits, are investigated from our point of view.

arXiv:1312.3036•Progress of Theoretical and Experimental Physics•Apr 1, 2014•2 citations
Weak values are conventionally extracted in the limit of vanishing measurement strength. At finite strength, the corresponding post-selected conditional averages generally acquire nonlinear corrections and need not retain their weak value interpretation. Here we identify a class of measurement protocols for which this expectation fails: the conditional value reconstructed from the measuring probe is exactly independent of the probe strength and therefore coincides with the real part of the weak value. We first analyze this phenomenon in the measurement--disturbance protocol introduced by Lund and Wiseman. We then establish conditions under which this invariance persists, showing that it is determined by the interplay between the probe interaction, a subsequent measurement interaction with an ancillary apparatus, and the final post-selection. These results demonstrate that weak coupling, although generally sufficient for accessing weak values, is not always necessary.
The paper asks when a post-selected probe average can equal the real part of a weak value at finite measurement strength, rather than only in the weak-coupling limit. It studies the Lund–Wiseman protocol for reconstructing Ozawa measurement precision and disturbance, then replaces its qubit meters with continuous-variable von Neumann pointers.
Exact calculations show that the calibrated conditional probe averages in the ideal qubit protocol are independent of probe strength, both for precision (ZZZ probing followed by a ZZZ apparatus interaction) and disturbance (XXX probing followed by a ZZZ apparatus interaction). Consequently, the corresponding weak-valued conditional probabilities are recovered without weak probing. For identical coupling observables, this invariance extends to arbitrary finite system dimension when conditioning on the apparatus pointer outcome.
For distinct observables, the analysis gives a sufficient condition: apparatus states associated with different initial probe-observable eigenstates must become orthogonal after post-selection. This removes interference contributions from both the conditional-average numerator and denominator. Real initial pointer wavefunctions and mutually unbiased coupling eigenbases ensure this condition for a two-dimensional system post-selected onto a probe-observable eigenstate. The result also extends to direct sums of invariant two-dimensional sectors. An explicit Gaussian-pointer qutrit counterexample shows that mutual unbiasedness alone is insufficient in higher dimensions.
The conditions are sufficient, not a general classification. The identified mechanism produces convex combinations of eigenvalues and therefore excludes anomalous weak values. Whether other strength-invariant mechanisms can support anomalous values remains open; the treatment concerns real weak values and restricts initial pointer wavefunctions to be real.
In the weak measurement regime, post-selection can result in the observation of anomalous weak values, seemingly contradicting the eigenvalue statistics observed when the measurement interaction is strong. Here, we investigate the dependence of meter statistics on measurement strength in a post-selected measurement. We find that the meter statistics in the intermediate regime between weak and strong measurements is nearly independent of measurement strength and show that, in this regime, the system performs a measurement of momentum on the meter. Our results show that post-selection is extremely sensitive to the action of the meter on the system, highlighting the difference between the weak measurement regime where this back-action is negligible and the average meter position is a valid measurement result, and the intermediate regime where the meter statistics should not be misinterpreted as a measurement outcome. The transition between weak values and eigenvalues is facilitated by a reversal of the roles of the system and the meter, where the post-selection acts as a readout of information about the meter. The intermediate measurement regime thus reveals that the apparent contradictions between anomalous weak values and eigenvalues originate from the non-classical effects of back-action on the post-selected meter statistics.
In a weak measurement the real and imaginary parts of a weak value participate in the shifts of the complementary variables of a pointer. While the real part represents the value of an observable in the limit of zero measurement strength, the imaginary one is regarded as the back-action due to the measurement with a post-selection, which has an influence on the post-selection probability. In this paper I give a case in which a real part could also appear as such a back-action in a post-selection probability on an equal footing with an imaginary one. It is also shown that both of the real and imaginary parts can be inferred by observing the probability in practice, which has an advantage that an additional system of a pointer is not needed.
Weak measurement of a quantum system followed by postselection based on a subsequent strong measurement gives rise to a quantity called the weak value : a complex number for which the interpretation has long been debated. We analyse the procedure of weak measurement and postselection, and the interpretation of the associated weak value, using a theory of classical mechanics supplemented by an epistemic restriction that is known to be operationally equivalent to a subtheory of quantum mechanics. Both the real and imaginary components of the weak value appear as phase space displacements in the postselected expectation values of the measurement device's position and momentum distributions, and we recover the same displacements as in the quantum case by studying the corresponding evolution in our theory of classical mechanics with an epistemic restriction. By using this epistemically restricted theory, we gain insight into the appearance of the weak value as a result of the statistical effects of post selection, and this provides us with an operational interpretation of the weak value, both its real and imaginary parts. We find that the imaginary part of the weak value is a measure of how much postselection biases the mean phase space distribution for a given amount of measurement disturbance. All such biases proportional to the imaginary part of the weak value vanish in the limit where disturbance due to measurement goes to zero. Our analysis also offers intuitive insight into how measurement disturbance can be minimized and the limits of weak measurement.
A weak measurement performed on a pre- and post-selected quantum system can result in an average value that lies outside of the observable's spectrum. This effect, usually referred to as an ``anomalous weak value'', is generally believed to be possible only when a non-trivial post-selection is performed, i.e., when only a particular subset of the data is considered. Here we show, however, that this is not the case in general: in scenarios in which several weak measurements are sequentially performed, an anomalous weak value can be obtained without post-selection, i.e., without discarding any data. We discuss several questions that this raises about the subtle relation between weak values and pointer positions for sequential weak measurements. Finally, we consider some implications of our results for the problem of distinguishing different causal structures.
Abstract Weak measurement (WM) based on post-selection is a useful tool for precision metrology due to the ability of amplifying weak physical effects. In this paper, we reveal the underlying mechanism of the amplification in the post-selected WM based on the weak-value amplification (WVA) and the almost balanced weak-values amplification (ABWVA) strategies. We find that the amplification stems from the interference between the local oscillator and signal components which are respectively associated with the initial system state and the state disturbance induced by the weak coupling. The magnitude of the amplification is proportional to the interference strength which is dominated by the post-selection and the coupling strength. Furthermore, our theory can perfectly explain the amplification limit in the WVA strategy and the anomalous amplification in the ABWVA strategy.